The presence of an absorber in one of the paths of an interferometer changes the output statistics of that interferometer in a fundamental manner. Since the individual quantum particles detected at any of the outputs of the interferometer have not been absorbed, any non-trivial effect of the absorber on the distribution of these particles over these paths is a counterfactual effect. Here, we quantify counterfactual effects by evaluating the information about the presence or absence of the absorber obtained from the output statistics, distinguishing between classical and quantum counterfactual effects. We identify the counterfactual gain which quantifies the advantage of quantum counterfactual protocols over classical counterfactual protocols, and show that this counterfactual gain can be separated into two terms: a semi-classical term related to the amplitude blocked by the absorber, and a Kirkwood-Dirac quasiprobability assigning a joint probability to the blocked path and the output port. A negative Kirkwood-Dirac term between a path and an output port indicates that inserting the absorber into that path will have a focussing effect, increasing the probability of particles arriving at that output port, resulting in a significant enhancement of the counterfactual gain. We show that the magnitude of quantum counterfactual effects cannot be explained by a simple removal of the absorbed particles, but originates instead from a well-defined back-action effect caused by the presence of the absorber in one path, on particles in other paths.
The presence of an absorber in one of the paths of an interferometer changes the output statistics of that interferometer in a fundamental manner. Since the individual quantum particles detected at any of the outputs of the interferometer have not been absorbed, any non-trivial effect of the absorber on the distribution of these particles over these paths is a counterfactual effect. Here, we quantify counterfactual effects by evaluating the information about the presence or absence of the absorber obtained from the output statistics, distinguishing between classical and quantum counterfactual effects. We identify the counterfactual gain which quantifies the advantage of quantum counterfactual protocols over classical counterfactual protocols, and show that this counterfactual gain can be separated into two terms: a semi-classical term related to the amplitude blocked by the absorber, and a Kirkwood-Dirac quasiprobability assigning a joint probability to the blocked path and the output port. A negative Kirkwood-Dirac term between a path and an output port indicates that inserting the absorber into that path will have a focussing effect, increasing the probability of particles arriving at that output port, resulting in a significant enhancement of the counterfactual gain. We show that the magnitude of quantum counterfactual effects cannot be explained by a simple removal of the absorbed particles, but originates instead from a well-defined back-action effect caused by the presence of the absorber in one path, on particles in other paths.
Abstract The presence of an absorber in one of the paths of an interferometer changes the output statistics of that interferometer in a fundamental manner. Since the individual quantum particles detected at any of the outputs of the interferometer have not been absorbed, any non-trivial effect of the absorber on the distribution of these particles over these paths is a counterfactual effect. Here, we quantify counterfactual effects by evaluating the information about the presence or absence of the absorber obtained from the output statistics, distinguishing between classical and quantum counterfactual effects. We identify the counterfactual gain which quantifies the advantage of quantum counterfactual protocols over classical counterfactual protocols, and show that this counterfactual gain can be separated into two terms: a semi-classical term related to the amplitude blocked by the absorber, and a Kirkwood-Dirac quasiprobability assigning a joint probability to the blocked path and the output port. A negative Kirkwood-Dirac term between a path and an output port indicates that inserting the absorber into that path will have a focussing effect, increasing the probability of particles arriving at that output port, resulting in a significant enhancement of the counterfactual gain. We show that the magnitude of quantum counterfactual effects cannot be explained by a simple removal of the absorbed particles, but originates instead from a well-defined back-action effect caused by the presence of the absorber in one path, on particles in other paths.
The presence of an absorber in one of the paths of an interferometer changes the output statistics of that interferometer in a fundamental manner. Since the individual quantum particles detected at any of the outputs of the interferometer have not been absorbed, any non-trivial effect of the absorber on the distribution of these particles over these paths is a counterfactual effect. Here, we quantify counterfactual effects by evaluating the information about the presence or absence of the absorber obtained from the output statistics, distinguishing between classical and quantum counterfactual effects. We identify the counterfactual gain which quantifies the advantage of quantum counterfactual protocols over classical counterfactual protocols, and show that this counterfactual gain can be separated into two terms: a semi-classical term related to the amplitude blocked by the absorber, and a Kirkwood-Dirac quasiprobability assigning a joint probability to the blocked path and the output port. A negative Kirkwood-Dirac term between a path and an output port indicates that inserting the absorber into that path will have a focussing effect, increasing the probability of particles arriving at that output port, resulting in a significant enhancement of the counterfactual gain. We show that the magnitude of quantum counterfactual effects cannot be explained by a simple removal of the absorbed particles, but originates instead from a well-defined back-action effect caused by the presence of the absorber in one path, on particles in other paths.
Negative Kirkwood--Dirac quasiprobabilities are credited with the quantum advantage of interaction-free measurement and postselected metrology. We test that claim on the task interaction-free measurement was designed for: learning about a sample letting it absorb as little light as possible. The Kirkwood--Dirac distribution of path and output gives the linear response to a weak sample: its real part responds to absorption, its imaginary part to a phase. For a pure single photon passing once through any interferometer, the Fisher information about transmittance per absorbed photon is the direct-transmission value minus a sum of squared imaginary parts: no interferometer or readout beats direct transmission. Negativity plays no role beyond concentrating information in weakly lit outputs. The imaginary parts of the Kirkwood-Dirac distribution depend on the output basis here, not on the sample, so a basis exists in which every term is real, which is optimal. A single photon gains information per absorbed photon only through a phase response, which for an optical line needs a thick or inhomogeneously broadened sample, or through many passes when absorptions go uncounted, as shown by a critically coupled resonator. For detecting a weak absorber, negativity gives a single-shot advantage that does not accumulate over multiple trials; advantage instead accumulates when there are outputs which are dark without the object, a case which needs no negativity.
Quantum contextuality, where measurement outcomes depend on the measurement context, implies a failure of classical realism in quantum systems. As recently shown, the transition between measurement contexts can be mapped onto the path that a quantum particle takes through an interferometer. Here, we investigate the relation between contextuality and the counterfactual gain observed in the output ports of such an interferometer when one of the paths is blocked. It is shown that experimental evidence of contextuality can only be obtained when counterfactual gain is observed for a specific combination of blocked path and output port. Using a silicon photonic integrated circuit, we experimentally observe the counterfactual gain for a selection of input states and evaluate the associated evidence for contextuality. The results confirm that contextuality can only be observed in the presence of counterfactual gain.
As shown in previous work, quantum contextuality can be represented by interference effects in a three-path interferometer. A Hardy-like paradox is obtained when the absence of photons in two internal paths seems to contradict the presence of photons in a specific input port. Here, we consider the effects of counterfactual control on this scenario by analyzing the changes to the paths through the interferometer when the seemingly impossible input path is blocked. The effects on photons that never interact with the absorber in the blocked path reveals a characteristic signature of quantum contextuality that may help to explain why quantum interference is incompatible with measurement independent realities.
Interaction-free measurement infers the presence of an absorbing object from a photon that, in the counterfactual sense, never interacted with it, and is widely described as a route to minimally invasive sensing. We ask what it actually buys, in estimation-theoretic terms. Written as a channel-estimation problem, the Elitzur-Vaidman interferometer carries exactly half the Fisher information about the object's transmissivity that direct transmission probing does, and the two schemes deliver identical Fisher information per absorbed photon. For measuring how transparent something is, the interferometer buys nothing. The advantage lies in discrimination, and we show that what it requires is not that the object be opaque but that the competing hypothesis be the object's absence. Against empty space the Chernoff information per absorbed photon grows almost linearly, as the number of Zeno cycles times its logarithm, even for a weakly absorbing object; between two partial transparencies it does not grow at all. Parasitic loss in the cycle caps the advantage. The number of conclusive interrogations per absorbed photon reaches a maximum inversely proportional to the loss per cycle, at an optimal cycle number that is likewise inversely proportional to it, which identifies the loss per cycle as the figure of merit governing how far interaction-free sensing can be pushed. Finally, the negative result is not special to the interferometer. For a single photon meeting a memoryless, non-dispersive object any number of times through arbitrary fixed optics, the accessible quantum Fisher information never exceeds that of the same incident flux spent on independent single-pass probes, and is generically far below it. This recovers the bound of Massar, Mitchison and Pironio for this class, by a short argument that also identifies when it is tight.