The European Physical Journal H

Using two-photon interference to perform ultrahigh-precision timing measurements: the origins of the Hong–Ou–Mandel effect

Gautier Depambour

Published Aug 26, 2026• 0 citations
Publisher
DOI
10.1140/epjh/s13129-026-00131-3

Related papers

Two-photon interference and the Hong-Ou-Mandel effect

Benjamin Vest, Lionel Jacubowiez

The Hong-Ou-Mandel (HOM) experiment is a landmark in quantum optics. A labwork version of this famous twophoton interference effect was developed at Institut d’Optique for students in engineering and MSc tracks. The setup enables the observation of the iconic HOM “dip” and the measurement of photon indistinguishability.

Photoniques•Jan 1, 2024•0 citations

Observation of high visibility Hong-Ou-Mandel interference via a time-resolved coincidence measurement

Motoki Tanaka

The Japan Society of Applied Physics•Feb 6, 2015•0 citations

Photon Counting and Timing in Quantum Optics Experiments

Andreas Ahlrichs, Benjamin Sprenger, Oliver J. Benson

Springer series on fluorescence•Jan 1, 2014•2 citations

Variation of the Hong-Ou-Mandel interference dip with crystal length

Sandeep Singh, Varun Sharma, Vimlesh Kumar +1 more

Two-photon interference, commonly known as Hong-Ou-Mandel (HOM) interference [1] , has attracted a great deal of interest in quantum sensing, including the precision timing measurements [2] and quantum optical coherence tomography [3] . While the dip of the HOM interference is the direct measure of the purity of the single-photon, the width of the HOM dip relates to the coherence time of the interfering photons. The broad consensus for using the HOM interferometer for sensing application remained the HOM dip width as the limiting factor for the precision measurements. As a consequence, the ultra-broadband photon sources have long been hailed as a vital prerequisite for ultra-precise HOM interferometry. Here, we have studied the variation in the width of the HOM dip with the crystal length for the continuous-wave pump laser and measured the HOM dip as low as 8.2 ± 0.2 µm corresponding to the spectral width of the single-photon source of 79.6±1.9 nm useful for sensitive sensing applications.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 21, 2021•1 citation

Sub-$\mu\mathrm{m}$ Axial Precision Depth Imaging with Entangled Two-Colour Hong-Ou-Mandel Microscopy

Cyril Torre, Alex McMillan, Jorge Monroy-Ruz +1 more

Hong-Ou-Mandel (HOM) interference results in a modified probability of bunching events when indistinguishable photons with a relative timing offset interact at a beamsplitter. Lyons et al. recently achieved attosecond precision in time delay measurement by applying a classical Fisher information analysis to HOM interference [1]. More recently an increase in the measurement precision has been shown by detuning the central wavelengths of the signal and idler from an entangled two-colour photon pair source and applied in temperature drift detection for optical fibres [2]. Here we exploit the timing resolution of the HOM interference to implement a robust 3D imaging microscope with tuneable sensitivity from millimetre to sub-micrometre.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 26, 2023•1 citation

Tunable Hong-Ou-Mandel interference via two-photon spin-orbit interaction

Qiuying Li, Minggui Liang, Jiawei Liu +6 more

Photonics Research•Oct 19, 2026•0 citations
Two-photon interference, commonly known as Hong-Ou-Mandel (HOM) interference [1] , has attracted a great deal of interest in quantum sensing, including the precision timing measurements [2] and quantum optical coherence tomography [3] . While the dip of the HOM interference is the direct measure of the purity of the single-photon, the width of the HOM dip relates to the coherence time of the interfering photons. The broad consensus for using the HOM interferometer for sensing application remained the HOM dip width as the limiting factor for the precision measurements. As a consequence, the ultra-broadband photon sources have long been hailed as a vital prerequisite for ultra-precise HOM interferometry. Here, we have studied the variation in the width of the HOM dip with the crystal length for the continuous-wave pump laser and measured the HOM dip as low as 8.2 ± 0.2 µm corresponding to the spectral width of the single-photon source of 79.6±1.9 nm useful for sensitive sensing applications.
Sub-μm\mu\mathrm{m}μm Axial Precision Depth Imaging with Entangled Two-Colour Hong-Ou-Mandel Microscopy
Hong-Ou-Mandel (HOM) interference results in a modified probability of bunching events when indistinguishable photons with a relative timing offset interact at a beamsplitter. Lyons et al. recently achieved attosecond precision in time delay measurement by applying a classical Fisher information analysis to HOM interference [1]. More recently an increase in the measurement precision has been shown by detuning the central wavelengths of the signal and idler from an entangled two-colour photon pair source and applied in temperature drift detection for optical fibres [2]. Here we exploit the timing resolution of the HOM interference to implement a robust 3D imaging microscope with tuneable sensitivity from millimetre to sub-micrometre.