Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)

Sub-$\mu\mathrm{m}$ Axial Precision Depth Imaging with Entangled Two-Colour Hong-Ou-Mandel Microscopy

Cyril Torre, Alex McMillan, Jorge Monroy-Ruz, Jonathan C. F. Matthews

Published Jun 26, 2023• 1 citation
Publisher

Abstract

Hong-Ou-Mandel (HOM) interference results in a modified probability of bunching events when indistinguishable photons with a relative timing offset interact at a beamsplitter. Lyons et al. recently achieved attosecond precision in time delay measurement by applying a classical Fisher information analysis to HOM interference [1]. More recently an increase in the measurement precision has been shown by detuning the central wavelengths of the signal and idler from an entangled two-colour photon pair source and applied in temperature drift detection for optical fibres [2]. Here we exploit the timing resolution of the HOM interference to implement a robust 3D imaging microscope with tuneable sensitivity from millimetre to sub-micrometre.

DOI
10.1109/cleo/europe-eqec57999.2023.10231753

Related papers

Hong-Ou-Mandel Enabled 3D Quantum Microscopy

Bienvenu I. Ndagano, Hugo Defienne, Ashley Lyons +1 more

We demonstrate micron-scale lateral and depth resolution imaging microscopy using photon bunching via HOM interference. 3D images are obtained without scanning using a SPAD camera and depth information is retrieved from two-photon coincidence events.

Imaging and Applied Optics•Jan 1, 2021•1 citation

Sub- μm axial precision depth imaging with entangled two-color Hong-Ou-Mandel microscopy

Cyril Torre, Alex R. McMillan, Jorge Monroy-Ruz +1 more

Using two entangled photons of different colors in a Hong-Ou-Mandel interference scheme, the authors show that they can precisely measure the thickness of a semitransparent sample. The depth sensitivity is adjustable and the method is resilient against fluctuations commonly encountered in biological samples.

arXiv:2212.02990•Physical Review A•Aug 24, 2023•10 citations

Attosecond delay metrology beyond the photon coherence time with spectrally resolved Hong-Ou-Mandel interferometry

Yingwen Zhang, Kyle Jordan, Duncan England +3 more

Hong-Ou-Mandel (HOM) interferometry enables delay estimation at the quantum precision limit but is traditionally constrained to path differences within the coherence time of the interfering photons. Here, we demonstrate single-measurement path-delay sensing at the measurement Cramer-Rao bound using spectrally resolved HOM interference, thereby removing the conventional dynamic-range limitation imposed by the photon coherence window, with no scanning required for calibration. By extracting delay information from the spectral interference fringes of spectrally entangled photon pairs, we retain near-optimal sensitivity over an operational range exceeding the photon coherence time by over two orders of magnitude. Using one million detected photon pairs, we achieve a time-delay precision of 20 attosecond (6 nm), while real-time operation (at 1 Hz) yields 330 attosecond (100 nm) precision. Because the estimator relies on fringe periodicity rather than absolute coincidence rates, the method is intrinsically robust to photon losses and variations in interference visibility, eliminating the need for recalibration. As a practical demonstration, we measure the thickness of a 300 um transmissive target with nanometer-scale precision. These results mark a significant step towards deploying quantum-limited measurements in real-world sensing applications using HOM interferometry.

quant-pharXiv:2607.16849•Reports on Progress in Physics•Jul 21, 2026•0 citations

High resolution Hong-Ou-Mandel microscope for depth imaging

Cyril Torre, Alex McMillan, Jonathan C. F. Matthews

We demonstrate the use of Hong-Ou-Mandel interference to resolve < 10µm scale depth-features of a semi-transparent sample and incorporate confocal imaging for 3D microscopy using photons from a wavelength-entangled pair photon source.

Imaging and Applied Optics•Jan 1, 2022•0 citations

Dual wavelength Hong-Ou-Mandel imaging

Ashley Lyons, Khales Kassem, Daniele Faccio +1 more

Hong-Ou-Mandel (HOM) interferometry, manifesting as photon bunching at a beamsplitter, can provide high precision optical path length sensing yet is robust to phase noise and immune to phase-wrapping. In this work we demonstrate how the sensitivity of HOM based imaging can be enhanced using dual wavelength illumination whilst maintaining its high level of robustness. We observe a beating in the second order correlation function due to the interference between the two wavelengths bands with a periodicity determined by the wavelength separation. These small-scale features can be used to precisely determine optical path length at the nanometre scale whilst a coarse (micron scale) estimation can be obtained by measuring only one of the bands.

Quantitative Phase Imaging•Mar 12, 2024•0 citations

Quantum Imaging of Birefringent Samples using Hong-Ou-Mandel Interference

Carolina Gonçalves, Tiago D. Ferreira, Catarina S. Monteiro +1 more

Two-photon interference in a Hong-Ou-Mandel (HOM) interferometer can be used as a quantum sensing mechanism due to the sensitivity of the interference dip to perturbations of the photon indistinguishability. In particular, recent works have generalized this concept to microscopy setups, but the sensitivity to optical path differences constrains its application to samples with thickness variation typically below a few micrometers if tracking changes in the coincidences at a fixed delay. Extending the concept to polarization microscopy and circumventing this limitation, this manuscript explores the use of a narrowband photon pair source with coherence length >1 mm to broaden the HOM dip. Thus, realistic sample-thickness variations introduce negligible temporal distinguishability, and changes in coincidence rate at the dip centre are then dominated by sample-induced polarization effects. To compute the polarization rotation, we develop a statistical model for the interferometer, derive the Fisher information, and establish a maximum-likelihood estimator for the local fast-axis angle. Recording dip and baseline frames at each sample position via raster scanning, the experimental results validate the framework, agreeing with classical polarized-intensity images while demonstrating operation at a maximum-precision regime and insensitiveness to layer thickness. Overall, the approach enclosed provides a quantum-based quantitative imaging of birefringent structures, which can motivate further advantageous applications, including enhanced signal-to-noise ratio and lower damage imaging of photosensitive samples.

quant-pharXiv:2512.19637•APL Photonics•Dec 23, 2025•2 citations
Sub-μm\mu\mathrm{m}μm Axial Precision Depth Imaging with Entangled Two-Colour Hong-Ou-Mandel Microscopy
Hong-Ou-Mandel (HOM) interference results in a modified probability of bunching events when indistinguishable photons with a relative timing offset interact at a beamsplitter. Lyons et al. recently achieved attosecond precision in time delay measurement by applying a classical Fisher information analysis to HOM interference [1]. More recently an increase in the measurement precision has been shown by detuning the central wavelengths of the signal and idler from an entangled two-colour photon pair source and applied in temperature drift detection for optical fibres [2]. Here we exploit the timing resolution of the HOM interference to implement a robust 3D imaging microscope with tuneable sensitivity from millimetre to sub-micrometre.
Hong-Ou-Mandel (HOM) interferometry enables delay estimation at the quantum precision limit but is traditionally constrained to path differences within the coherence time of the interfering photons. Here, we demonstrate single-measurement path-delay sensing at the measurement Cramer-Rao bound using spectrally resolved HOM interference, thereby removing the conventional dynamic-range limitation imposed by the photon coherence window, with no scanning required for calibration. By extracting delay information from the spectral interference fringes of spectrally entangled photon pairs, we retain near-optimal sensitivity over an operational range exceeding the photon coherence time by over two orders of magnitude. Using one million detected photon pairs, we achieve a time-delay precision of 20 attosecond (6 nm), while real-time operation (at 1 Hz) yields 330 attosecond (100 nm) precision. Because the estimator relies on fringe periodicity rather than absolute coincidence rates, the method is intrinsically robust to photon losses and variations in interference visibility, eliminating the need for recalibration. As a practical demonstration, we measure the thickness of a 300 um transmissive target with nanometer-scale precision. These results mark a significant step towards deploying quantum-limited measurements in real-world sensing applications using HOM interferometry.
Hong-Ou-Mandel (HOM) interferometry, manifesting as photon bunching at a beamsplitter, can provide high precision optical path length sensing yet is robust to phase noise and immune to phase-wrapping. In this work we demonstrate how the sensitivity of HOM based imaging can be enhanced using dual wavelength illumination whilst maintaining its high level of robustness. We observe a beating in the second order correlation function due to the interference between the two wavelengths bands with a periodicity determined by the wavelength separation. These small-scale features can be used to precisely determine optical path length at the nanometre scale whilst a coarse (micron scale) estimation can be obtained by measuring only one of the bands.
Two-photon interference in a Hong-Ou-Mandel (HOM) interferometer can be used as a quantum sensing mechanism due to the sensitivity of the interference dip to perturbations of the photon indistinguishability. In particular, recent works have generalized this concept to microscopy setups, but the sensitivity to optical path differences constrains its application to samples with thickness variation typically below a few micrometers if tracking changes in the coincidences at a fixed delay. Extending the concept to polarization microscopy and circumventing this limitation, this manuscript explores the use of a narrowband photon pair source with coherence length >1 mm to broaden the HOM dip. Thus, realistic sample-thickness variations introduce negligible temporal distinguishability, and changes in coincidence rate at the dip centre are then dominated by sample-induced polarization effects. To compute the polarization rotation, we develop a statistical model for the interferometer, derive the Fisher information, and establish a maximum-likelihood estimator for the local fast-axis angle. Recording dip and baseline frames at each sample position via raster scanning, the experimental results validate the framework, agreeing with classical polarized-intensity images while demonstrating operation at a maximum-precision regime and insensitiveness to layer thickness. Overall, the approach enclosed provides a quantum-based quantitative imaging of birefringent structures, which can motivate further advantageous applications, including enhanced signal-to-noise ratio and lower damage imaging of photosensitive samples.