Integrated and Endoscopic NV-Based Quantum Magnetometer

Johannes Wesseler, Roland Nagy

Published Mar 19, 2026• 0 citations
Publisher

Abstract

AbstractNitrogen-vacancy (NV) centers in diamond show disruptive potential in quantum sensing, enabling groundbreaking applications in nanoscale microscopy [1] and single-cell imaging [2]. They also promise insight into processes in complex electrochemical systems such as batteries [3]. However, most successes in these applications remain bound to laboratory conditions.We present a novel architecture for an endoscopic and fully fiber-coupled quantum magnetometer. Our sensor features a 5 mm diameter head with a micro-lens optical front-end for efficient optical excitation and fluorescence collection. An FPGA integrates the control and readout functionalities, including microwave synthesis and lock-in demodulation. This highly integrated platform achieves a magnetic field sensitivity of 150 pT/√Hz, presenting a performance record for endoscopic CW-ODMR based NV-based sensors. We verify the sensor's practical utility by performing 2D magnetic field scans of a commercial battery, demonstrating its capability in a real application scenario. This work marks a significant advance in the transition of endoscopic quantum sensors from the lab to the field.

DOI
10.5281/zenodo.21256672

Related papers

Sensitive endoscopic diamond magnetometer for non-contact sensing in confined environments

Johannes Wesseler, Roland Nagy

Transitioning quantum magnetometry from laboratory environments to real-world applications has been limited by a persistent trade-off between sensor miniaturization and magnetic sensitivity. While bulky systems can achieve high sensitivity, endoscopic probes commonly suffer from inefficient fluorescence collection and reduced performance. Here we resolve this trade-off and present a miniaturized diamond quantum magnetometer with a 6 mm diameter endoscopic sensor head, achieving a magnetic-field sensitivity of 91 pT/sqrt(Hz) with a 2 kHz measurement bandwidth in a magnetically unshielded environment. The fluorescence collection bottleneck is overcome by separating excitation and collection into different cores of a fused multi-core fiber bundle, coupled to the diamond through a custom high-numerical-aperture micro-objective. A compact FPGA-based backend performs microwave control, lock-in detection and real-time resonance tracking, enabling robust operation during magnetic-field imaging. To demonstrate the practical utility of the miniaturized sensor, we image the magnetic field of a commercial lithium-ion pouch cell during charge and discharge and reconstruct depth-integrated current-density maps of the current flow. These results show that endoscopic diamond magnetometers can combine high sensitivity with a probe geometry suitable for confined, unshielded measurements, opening new avenues in battery technology and beyond.

quant-pharXiv:2606.18871•Jun 18, 2026

Miniaturized magnetic-field sensor based on nitrogen-vacancy centers

Sigfrid Lindén Johansson, Dennis Lönard, Isabel Cardoso Barbosa +3 more

The nitrogen-vacancy (NV) center in diamond is a prime candidate for quantum sensing technologies. Here, we present a fully integrated and mechanically robust fiber-based endoscopic sensor with a tip diameter of 1.25 mm . On its tip, a direct laser-writing process is used to secure a diamond containing NV centers above the fiber’s core inside a polymer structure. Additionally, a metallic direct laser-written antenna structure next to the fiber facet allows efficient microwave manipulation of NV-center spins. The sensor achieves a shot-noise-limited magnetic-field sensitivity of 5.9 nT / Hz using a 15 − μ m -sized microdiamond at a microwave power of 50 mW and an optical power of 2.15 mW . Using lock-in techniques, we measure a sensitivity of 51.8 nT / Hz . Furthermore, we introduce a dual-fiber concept that enables, in combination with a direct laser-written structure, independent guiding of excitation and fluorescence light and thus reduces background autofluorescence. Moreover, controlled guiding of excitation light to the diamond while avoiding sample illumination may enable operation in light-sensitive environments such as biological tissue. While the demonstrated sensitivity is achieved using a single-fiber configuration, the dual-fiber approach provides a path toward integrating smaller diamonds, where autofluorescence would otherwise limit performance. We demonstrate the capability of vector magnetic-field measurements in the type of magnetic field used in state-of-the-art ultracold quantum gas experiments, opening a potential arena in which high resolution and high sensitivity are required.

arXiv:2402.19372•Physical Review Applied•Oct 24, 2025•14 citations

Picotesla fiberized diamond-based AC magnetometer

Shao-Chun Zhang, Yong Liu, Long‐Kun Shan +7 more

Portable quantum sensors are crucial for developing practical quantum sensing and metrology applications. Fiberized nitrogen-vacancy (NV) centers in diamonds have emerged as one of the most promising candidates for compact quantum sensors. Nevertheless, due to the difficulty of coherently controlling the ensemble spin and noise suppression in a large volume, it often faces problems such as reduced sensitivity and narrowed bandwidth in integrated lensless applications. Here, we propose a fluorescence signal treatment method for NV spin ensemble manipulation by the exponential fitting of spin polarization processes, instead of integrating the photon emission. This enables spin state readout with a high signal-to-noise ratio and applies to the pulse sensing protocols for large-volume NV spins. Based on this, we further developed a fiberized diamond-based AC magnetometer. With an XY8-N dynamical decoupling pulse sequence, we demonstrated a T2-limited sensitivity of 8 pT/Hz and T1-limited frequency resolution of 90 Hz over a wide frequency band from 100 kHz to 3 MHz. This integrated diamond sensor leverages quantum coherence to achieve enhanced sensitivity in detecting AC magnetic fields, making it suitable for implementation in a compact and portable endoscopic sensor.

Photonics Research•Mar 29, 2024•11 citations

Efficient Fluorescence Coupling Integrated Fiber Magnetometer Based on Nitrogen Vacancy Centers

Yuhao Li, Li Xia, Junchang Huang

A magnetic field sensor based on a fiber-optic integrated probe at the center of a nitrogen vacancy (NV) is proposed and demonstrated. Fiber optics are utilized to replace all conventional spatial optics while efficiently enabling laser excitation and fluorescence collection from diamond. Optical models were developed to study the fluorescence collection efficiency of diamond. The fiber-coupled probe was simulated and its efficiency was improved to 3.062% compared to the 0.607% fluorescence coupling efficiency of the fiber. The optical probe magnetic resonance (ODMR) phenomenon was successfully observed and significantly improved the magnetic field sensitivity to 5.3 nT/Hz1/2, which proved the feasibility and performance compared with the conventional confocal NV-centered magnetometer.

International Conference on Optical Communications and Networks (ICOCN)•Jul 26, 2024•0 citations

Quantum Co-Magnetometer Using Diamond Nitrogen-Vacancy Centers and Rubidium Cells

Ittai Shalev, Kfir Levi, Rotem Malkinson +3 more

Recent advances in chip scale magnetic quantum sensing have produced platforms that pair unprecedented sensitivity with extreme miniaturization. Here, we demonstrate a hybrid quantum sensor by combining Nitrogen-Vacancy (NV) centers in diamond with a rubidium (Rb) vapor cell, designed for precise magnetic field measurements and quantum exploration. The hybrid comagnetometer leverages the high resolution vector magnetic sensing of NV centers along with the high scalar field sensitivity of the Rb vapor, enhancing the estimation of the magnetic field in terms of magnitude, direction and spatial distribution. A micromachined mm scale vapor cell containing Rb atoms is paired with a bulk diamond, enabling optical and microwave control of both quantum systems for integrated field estimation. Simulations and experimental results confirm the improved accuracy of the system in magnetic field measurements, demonstrating a beyond 10 dB improvement. This NV and Rb platform offers a versatile route toward portable, sensitive magnetometry and opens new possibilities for integrated, multi-modal quantum sensing.

arXiv:2508.15638•Aug 21, 2025•2 citations

Toward a CMOS-integrated quantum diamond biosensor based on NV centers

Ioannis Varveris, Gianni D. Aliberti, Felix J. Barzilaij +6 more

We report progress toward a CMOS-integrated quantum diamond biosensing platform that combines nitrogen-vacancy (NV) centers in diamond with a custom 40 nm CMOS Single-Photon Avalanche Diode (SPAD) array. The system integrates on-chip active quenching and digital readout with external FPGA-based photon counting, compact microwave delivery, and practical optical excitation and collection schemes to support widefield optically detected magnetic resonance (ODMR). System-level design considerations spanning fluorescence collection efficiency, detector count-rate capability, and microwave homogeneity are analyzed with biological compatibility and scalability in mind. Using superparamagnetic iron oxide nanoparticle (SPION)-labeled HEK293T cells as a representative use case, simple dipole-field estimates indicate that sub-$μ$T sensitivity is required to resolve ODMR shifts within typical ensemble linewidths. Based on the proposed architecture and efficiency analysis, a magnetic field sensitivity of approximately 90 nT/$\sqrt{\mathrm{Hz}}$ per pixel is estimated. These results outline a practical path from optics-heavy quantum diamond microscopes toward compact, CMOS-integrated NV-based biosensors for quantitative magnetic imaging in complex biological environments.

physics.app-phCross-listedarXiv:2602.20437•Feb 25, 2026
AbstractNitrogen-vacancy (NV) centers in diamond show disruptive potential in quantum sensing, enabling groundbreaking applications in nanoscale microscopy [1] and single-cell imaging [2]. They also promise insight into processes in complex electrochemical systems such as batteries [3]. However, most successes in these applications remain bound to laboratory conditions.We present a novel architecture for an endoscopic and fully fiber-coupled quantum magnetometer. Our sensor features a 5 mm diameter head with a micro-lens optical front-end for efficient optical excitation and fluorescence collection. An FPGA integrates the control and readout functionalities, including microwave synthesis and lock-in demodulation. This highly integrated platform achieves a magnetic field sensitivity of 150 pT/√Hz, presenting a performance record for endoscopic CW-ODMR based NV-based sensors. We verify the sensor's practical utility by performing 2D magnetic field scans of a commercial battery, demonstrating its capability in a real application scenario. This work marks a significant advance in the transition of endoscopic quantum sensors from the lab to the field.
Transitioning quantum magnetometry from laboratory environments to real-world applications has been limited by a persistent trade-off between sensor miniaturization and magnetic sensitivity. While bulky systems can achieve high sensitivity, endoscopic probes commonly suffer from inefficient fluorescence collection and reduced performance. Here we resolve this trade-off and present a miniaturized diamond quantum magnetometer with a 6 mm diameter endoscopic sensor head, achieving a magnetic-field sensitivity of 91 pT/sqrt(Hz) with a 2 kHz measurement bandwidth in a magnetically unshielded environment. The fluorescence collection bottleneck is overcome by separating excitation and collection into different cores of a fused multi-core fiber bundle, coupled to the diamond through a custom high-numerical-aperture micro-objective. A compact FPGA-based backend performs microwave control, lock-in detection and real-time resonance tracking, enabling robust operation during magnetic-field imaging. To demonstrate the practical utility of the miniaturized sensor, we image the magnetic field of a commercial lithium-ion pouch cell during charge and discharge and reconstruct depth-integrated current-density maps of the current flow. These results show that endoscopic diamond magnetometers can combine high sensitivity with a probe geometry suitable for confined, unshielded measurements, opening new avenues in battery technology and beyond.
The nitrogen-vacancy (NV) center in diamond is a prime candidate for quantum sensing technologies. Here, we present a fully integrated and mechanically robust fiber-based endoscopic sensor with a tip diameter of 1.25 mm . On its tip, a direct laser-writing process is used to secure a diamond containing NV centers above the fiber’s core inside a polymer structure. Additionally, a metallic direct laser-written antenna structure next to the fiber facet allows efficient microwave manipulation of NV-center spins. The sensor achieves a shot-noise-limited magnetic-field sensitivity of 5.9 nT / Hz using a 15 − μ m -sized microdiamond at a microwave power of 50 mW and an optical power of 2.15 mW . Using lock-in techniques, we measure a sensitivity of 51.8 nT / Hz . Furthermore, we introduce a dual-fiber concept that enables, in combination with a direct laser-written structure, independent guiding of excitation and fluorescence light and thus reduces background autofluorescence. Moreover, controlled guiding of excitation light to the diamond while avoiding sample illumination may enable operation in light-sensitive environments such as biological tissue. While the demonstrated sensitivity is achieved using a single-fiber configuration, the dual-fiber approach provides a path toward integrating smaller diamonds, where autofluorescence would otherwise limit performance. We demonstrate the capability of vector magnetic-field measurements in the type of magnetic field used in state-of-the-art ultracold quantum gas experiments, opening a potential arena in which high resolution and high sensitivity are required.
Portable quantum sensors are crucial for developing practical quantum sensing and metrology applications. Fiberized nitrogen-vacancy (NV) centers in diamonds have emerged as one of the most promising candidates for compact quantum sensors. Nevertheless, due to the difficulty of coherently controlling the ensemble spin and noise suppression in a large volume, it often faces problems such as reduced sensitivity and narrowed bandwidth in integrated lensless applications. Here, we propose a fluorescence signal treatment method for NV spin ensemble manipulation by the exponential fitting of spin polarization processes, instead of integrating the photon emission. This enables spin state readout with a high signal-to-noise ratio and applies to the pulse sensing protocols for large-volume NV spins. Based on this, we further developed a fiberized diamond-based AC magnetometer. With an XY8-N dynamical decoupling pulse sequence, we demonstrated a T2-limited sensitivity of 8 pT/Hz and T1-limited frequency resolution of 90 Hz over a wide frequency band from 100 kHz to 3 MHz. This integrated diamond sensor leverages quantum coherence to achieve enhanced sensitivity in detecting AC magnetic fields, making it suitable for implementation in a compact and portable endoscopic sensor.
A magnetic field sensor based on a fiber-optic integrated probe at the center of a nitrogen vacancy (NV) is proposed and demonstrated. Fiber optics are utilized to replace all conventional spatial optics while efficiently enabling laser excitation and fluorescence collection from diamond. Optical models were developed to study the fluorescence collection efficiency of diamond. The fiber-coupled probe was simulated and its efficiency was improved to 3.062% compared to the 0.607% fluorescence coupling efficiency of the fiber. The optical probe magnetic resonance (ODMR) phenomenon was successfully observed and significantly improved the magnetic field sensitivity to 5.3 nT/Hz1/2, which proved the feasibility and performance compared with the conventional confocal NV-centered magnetometer.
Recent advances in chip scale magnetic quantum sensing have produced platforms that pair unprecedented sensitivity with extreme miniaturization. Here, we demonstrate a hybrid quantum sensor by combining Nitrogen-Vacancy (NV) centers in diamond with a rubidium (Rb) vapor cell, designed for precise magnetic field measurements and quantum exploration. The hybrid comagnetometer leverages the high resolution vector magnetic sensing of NV centers along with the high scalar field sensitivity of the Rb vapor, enhancing the estimation of the magnetic field in terms of magnitude, direction and spatial distribution. A micromachined mm scale vapor cell containing Rb atoms is paired with a bulk diamond, enabling optical and microwave control of both quantum systems for integrated field estimation. Simulations and experimental results confirm the improved accuracy of the system in magnetic field measurements, demonstrating a beyond 10 dB improvement. This NV and Rb platform offers a versatile route toward portable, sensitive magnetometry and opens new possibilities for integrated, multi-modal quantum sensing.
We report progress toward a CMOS-integrated quantum diamond biosensing platform that combines nitrogen-vacancy (NV) centers in diamond with a custom 40 nm CMOS Single-Photon Avalanche Diode (SPAD) array. The system integrates on-chip active quenching and digital readout with external FPGA-based photon counting, compact microwave delivery, and practical optical excitation and collection schemes to support widefield optically detected magnetic resonance (ODMR). System-level design considerations spanning fluorescence collection efficiency, detector count-rate capability, and microwave homogeneity are analyzed with biological compatibility and scalability in mind. Using superparamagnetic iron oxide nanoparticle (SPION)-labeled HEK293T cells as a representative use case, simple dipole-field estimates indicate that sub-μμμT sensitivity is required to resolve ODMR shifts within typical ensemble linewidths. Based on the proposed architecture and efficiency analysis, a magnetic field sensitivity of approximately 90 nT/Hz\sqrt{\mathrm{Hz}}Hz​ per pixel is estimated. These results outline a practical path from optics-heavy quantum diamond microscopes toward compact, CMOS-integrated NV-based biosensors for quantitative magnetic imaging in complex biological environments.