Miniaturized magnetic-field sensor based on nitrogen-vacancy centers

Sigfrid Lindén Johansson, Dennis Lönard, Isabel Cardoso Barbosa, Jonas Gutsche, Jonas Witzenrath, Artur Widera

Published Oct 24, 2025• 14 citations
arXivHTMLPDF

Abstract

The nitrogen-vacancy (NV) center in diamond is a prime candidate for quantum sensing technologies. Here, we present a fully integrated and mechanically robust fiber-based endoscopic sensor with a tip diameter of 1.25 mm . On its tip, a direct laser-writing process is used to secure a diamond containing NV centers above the fiber’s core inside a polymer structure. Additionally, a metallic direct laser-written antenna structure next to the fiber facet allows efficient microwave manipulation of NV-center spins. The sensor achieves a shot-noise-limited magnetic-field sensitivity of 5.9 nT / Hz using a 15 − μ m -sized microdiamond at a microwave power of 50 mW and an optical power of 2.15 mW . Using lock-in techniques, we measure a sensitivity of 51.8 nT / Hz . Furthermore, we introduce a dual-fiber concept that enables, in combination with a direct laser-written structure, independent guiding of excitation and fluorescence light and thus reduces background autofluorescence. Moreover, controlled guiding of excitation light to the diamond while avoiding sample illumination may enable operation in light-sensitive environments such as biological tissue. While the demonstrated sensitivity is achieved using a single-fiber configuration, the dual-fiber approach provides a path toward integrating smaller diamonds, where autofluorescence would otherwise limit performance. We demonstrate the capability of vector magnetic-field measurements in the type of magnetic field used in state-of-the-art ultracold quantum gas experiments, opening a potential arena in which high resolution and high sensitivity are required.

DOI
10.1103/lbqj-d5zv

Related papers

Integrated and Endoscopic NV-Based Quantum Magnetometer

Johannes Wesseler, Roland Nagy

AbstractNitrogen-vacancy (NV) centers in diamond show disruptive potential in quantum sensing, enabling groundbreaking applications in nanoscale microscopy [1] and single-cell imaging [2]. They also promise insight into processes in complex electrochemical systems such as batteries [3]. However, most successes in these applications remain bound to laboratory conditions.We present a novel architecture for an endoscopic and fully fiber-coupled quantum magnetometer. Our sensor features a 5 mm diameter head with a micro-lens optical front-end for efficient optical excitation and fluorescence collection. An FPGA integrates the control and readout functionalities, including microwave synthesis and lock-in demodulation. This highly integrated platform achieves a magnetic field sensitivity of 150 pT/√Hz, presenting a performance record for endoscopic CW-ODMR based NV-based sensors. We verify the sensor's practical utility by performing 2D magnetic field scans of a commercial battery, demonstrating its capability in a real application scenario. This work marks a significant advance in the transition of endoscopic quantum sensors from the lab to the field.

•Mar 19, 2026•0 citations

Microscale fiber-integrated vector magnetometer with on-tip field biasing using N - V ensembles in diamond microcrystals

Jonas Homrighausen, Frederik Hoffmann, Jens Pogorzelski +2 more

In quantum sensing of magnetic fields, ensembles of nitrogen-vacancy centers in diamond offer high sensitivity, high bandwidth and outstanding spatial resolution while operating in harsh environments. Moreover, the orientation of defect centers along four crystal axes forms an intrinsic coordinate system, enabling vector magnetometry within a single diamond crystal. While most vector magnetometers rely on a known bias magnetic field for full recovery of three-dimensional (3D) field information, employing external 3D Helmholtz coils or permanent magnets results in bulky, laboratory-bound setups, impeding miniaturization of the device. Here, a novel approach is presented that utilizes a fiber-integrated microscale coil at the fiber tip to generate a localized uniaxial magnetic field. The same fiber-tip coil is used in parallel for spin control by combining dc and microwave signals in a bias tee. To implement vector magnetometry using a uniaxial bias field, the orientation of the diamond crystal is preselected and then fully characterized by rotating a static magnetic field in three planes of rotation. The measurement of vector magnetic fields in the full solid angle is demonstrated with a shot-noise-limited sensitivity of 19.4 nT/Hz 1 / 2 and microscale spatial resolution while achieving a fiber sensor head cross section of less than 1 mm 2 . Published by the American Physical Society 2024

arXiv:2404.14089•Physical Review Applied•Sep 12, 2024•14 citations

Magnetically sensitive fiber probe with nitrogen-vacancy center nanodiamonds integrated in a suspended core

Adam Filipkowski, Mariusz Mrózek, Grzegorz Stępniewski +6 more

Efficient collection of photoluminescence arising from spin dynamics of nitrogen vacancy (NV) centers in diamond is important for practical applications involving precise magnetic field or temperature mapping. These goals may be realized by the integration of nanodiamond particles with optical fibers and volumetric doping of the particles alongside the fiber core. That approach combines the advantages of robust axial fixation of NV diamonds with a direct spatial overlap of their fluorescence with the guided mode of the fiber. We developed a suspended core silicate glass fiber with 750 nm-diameter nanodiamonds located centrally in the 1.5 µm-core cross-section along its axis. The developed fiber probe was tested for its magnetic sensing performance in optically detected magnetic resonance measurements using a 24 cm-long fiber sample, with the NV excitation and fluorescence collection from the far ends of the sample and yielding optical readout contrast of 7% resulting in 0.5 µT·Hz-1/2 magnetic field sensitivity, two orders of magnitude better than in earlier designs. Thanks to its improved fluorescence confinement, the developed probe could find application in magnetic sensing over extended fiber length, magnetic field mapping or gradiometry.

Optics Express•May 3, 2022•20 citations

Microscale fiber-integrated vector magnetometer with on-tip field biasing using N-V ensembles in diamond microcrystals

Jonas Homrighausen, Frederik Hoffmann, Jens Pogorzelski +2 more

In quantum sensing of magnetic fields, ensembles of nitrogen-vacancy centers in diamond offer high sensitivity, high bandwidth and outstanding spatial resolution while operating in harsh environments. Moreover, the orientation of defect centers along four crystal axes forms an intrinsic coordinate system, enabling vector magnetometry within a single diamond crystal. While most vector magnetometers rely on a known bias magnetic field for full recovery of three-dimensional (3D) field information, employing external 3D Helmholtz coils or permanent magnets results in bulky, laboratory-bound setups, impeding miniaturization of the device. Here, a novel approach is presented that utilizes a fiber-integrated microscale coil at the fiber tip to generate a localized uniaxial magnetic field. The same fiber-tip coil is used in parallel for spin control by combining dc and microwave signals in a bias tee. To implement vector magnetometry using a uniaxial bias field, the orientation of the diamond crystal is preselected and then fully characterized by rotating a static magnetic field in three planes of rotation. The measurement of vector magnetic fields in the full solid angle is demonstrated with a shot-noise-limited sensitivity of 19.4 nT/Hz 1/2 and microscale spatial resolution while achieving a fiber sensor head cross section of less than 1 mm2

•Mar 18, 2026•0 citations

Efficient nitrogen-vacancy centers’ fluorescence excitation and collection from micrometer-sized diamond by a tapered optical fiber in endoscope-type configuration

Dewen Duan, Guanxiang Du, Vinaya K. Kavatamane +4 more

Using an optical fiber to both excite the nitrogen-vacancy (NV) center in diamond and collect its fluorescence is essential to build NV-based endoscope-type sensor. Such endoscope-type sensor can reach inaccessible fields for traditional NV-based sensors built by bulky optical components and extend the application areas. Since single NV's fluorescence is weak and can easily be buried in fluorescence from optical fiber core's oxide defects excited by the green laser, fixing a micrometer size diamond containing high-density NVs rather than a nanodiamond containing single NV or several NVs on the apex of an optical fiber to build an endoscope-type sensor is more implementable. Unfortunately, due to small numerical aperture (NA), most of the optical fibers have a low fluorescence collection efficiency, which limits the sensitivity and spatial resolution of the NV-based endoscope-type sensor. Here, using a tapered optical fiber (TOF) tip, we significantly improve the efficiency of the laser excitation and fluorescence collection of the NV ensembles in diamond. This could potentially enhance the sensitivity and spatial resolution of the NV-based endoscope-type sensor. Numerical calculations show that the TOF tip delivers a high NA and has a high NV excitation and fluorescence collection efficiency. Experiments demonstrate that such TOF tip can obtain up to over 7-fold excitation efficiency and over 15-fold fluorescence collection efficiency of that from a flat-ended fiber (non-TOF) tip.

arXiv:1810.03320•Optics Express•Feb 22, 2019•56 citations

Nanophotonic quantum magnetometry in a spin-dense diamond cavity

Nicholas J. Sorensen, Elham Zohari, Joshua S. Wildeman +3 more

Quantum sensors based on the nitrogen-vacancy (NV) center in diamond are leading platforms for high-sensitivity magnetometry with nanometer-scale resolution. State-of-the-art implementations, however, typically rely on bulky free-space optics or sacrifice spatial resolution to achieve high sensitivities. Here, we realize an integrated platform that overcomes this trade-off by fabricating monolithic whispering-gallery-mode cavities from a diamond chip containing a high density of NV centers and by evanescently coupling excitation to and photoluminescence from the cavity using a tapered optical fiber. Employing a lock-in-amplified Ramsey magnetometry scheme, we achieve a photon-shot-noise-limited DC sensitivity of $58\,\text{nT}/\sqrt{\text{Hz}}$---the best sensitivity reported to date for a nanofabricated cavity-based magnetometer. The microscopic cavity size enables micrometer-scale spatial resolution and low-power operation, while fiber-coupling provides a path to scalable on-chip integration. Arrays of such sensors could enable NV-NMR spectroscopy of sub-nanoliter samples, new magnetic-gradient imaging architectures, and compact biosensing platforms.

physics.opticsCross-listedarXiv:2511.19831•Physical Review Applied•Nov 26, 2025•3 citations
The nitrogen-vacancy (NV) center in diamond is a prime candidate for quantum sensing technologies. Here, we present a fully integrated and mechanically robust fiber-based endoscopic sensor with a tip diameter of 1.25 mm . On its tip, a direct laser-writing process is used to secure a diamond containing NV centers above the fiber’s core inside a polymer structure. Additionally, a metallic direct laser-written antenna structure next to the fiber facet allows efficient microwave manipulation of NV-center spins. The sensor achieves a shot-noise-limited magnetic-field sensitivity of 5.9 nT / Hz using a 15 − μ m -sized microdiamond at a microwave power of 50 mW and an optical power of 2.15 mW . Using lock-in techniques, we measure a sensitivity of 51.8 nT / Hz . Furthermore, we introduce a dual-fiber concept that enables, in combination with a direct laser-written structure, independent guiding of excitation and fluorescence light and thus reduces background autofluorescence. Moreover, controlled guiding of excitation light to the diamond while avoiding sample illumination may enable operation in light-sensitive environments such as biological tissue. While the demonstrated sensitivity is achieved using a single-fiber configuration, the dual-fiber approach provides a path toward integrating smaller diamonds, where autofluorescence would otherwise limit performance. We demonstrate the capability of vector magnetic-field measurements in the type of magnetic field used in state-of-the-art ultracold quantum gas experiments, opening a potential arena in which high resolution and high sensitivity are required.
AbstractNitrogen-vacancy (NV) centers in diamond show disruptive potential in quantum sensing, enabling groundbreaking applications in nanoscale microscopy [1] and single-cell imaging [2]. They also promise insight into processes in complex electrochemical systems such as batteries [3]. However, most successes in these applications remain bound to laboratory conditions.We present a novel architecture for an endoscopic and fully fiber-coupled quantum magnetometer. Our sensor features a 5 mm diameter head with a micro-lens optical front-end for efficient optical excitation and fluorescence collection. An FPGA integrates the control and readout functionalities, including microwave synthesis and lock-in demodulation. This highly integrated platform achieves a magnetic field sensitivity of 150 pT/√Hz, presenting a performance record for endoscopic CW-ODMR based NV-based sensors. We verify the sensor's practical utility by performing 2D magnetic field scans of a commercial battery, demonstrating its capability in a real application scenario. This work marks a significant advance in the transition of endoscopic quantum sensors from the lab to the field.
In quantum sensing of magnetic fields, ensembles of nitrogen-vacancy centers in diamond offer high sensitivity, high bandwidth and outstanding spatial resolution while operating in harsh environments. Moreover, the orientation of defect centers along four crystal axes forms an intrinsic coordinate system, enabling vector magnetometry within a single diamond crystal. While most vector magnetometers rely on a known bias magnetic field for full recovery of three-dimensional (3D) field information, employing external 3D Helmholtz coils or permanent magnets results in bulky, laboratory-bound setups, impeding miniaturization of the device. Here, a novel approach is presented that utilizes a fiber-integrated microscale coil at the fiber tip to generate a localized uniaxial magnetic field. The same fiber-tip coil is used in parallel for spin control by combining dc and microwave signals in a bias tee. To implement vector magnetometry using a uniaxial bias field, the orientation of the diamond crystal is preselected and then fully characterized by rotating a static magnetic field in three planes of rotation. The measurement of vector magnetic fields in the full solid angle is demonstrated with a shot-noise-limited sensitivity of 19.4 nT/Hz 1 / 2 and microscale spatial resolution while achieving a fiber sensor head cross section of less than 1 mm 2 . Published by the American Physical Society 2024
Efficient collection of photoluminescence arising from spin dynamics of nitrogen vacancy (NV) centers in diamond is important for practical applications involving precise magnetic field or temperature mapping. These goals may be realized by the integration of nanodiamond particles with optical fibers and volumetric doping of the particles alongside the fiber core. That approach combines the advantages of robust axial fixation of NV diamonds with a direct spatial overlap of their fluorescence with the guided mode of the fiber. We developed a suspended core silicate glass fiber with 750 nm-diameter nanodiamonds located centrally in the 1.5 µm-core cross-section along its axis. The developed fiber probe was tested for its magnetic sensing performance in optically detected magnetic resonance measurements using a 24 cm-long fiber sample, with the NV excitation and fluorescence collection from the far ends of the sample and yielding optical readout contrast of 7% resulting in 0.5 µT·Hz-1/2 magnetic field sensitivity, two orders of magnitude better than in earlier designs. Thanks to its improved fluorescence confinement, the developed probe could find application in magnetic sensing over extended fiber length, magnetic field mapping or gradiometry.
In quantum sensing of magnetic fields, ensembles of nitrogen-vacancy centers in diamond offer high sensitivity, high bandwidth and outstanding spatial resolution while operating in harsh environments. Moreover, the orientation of defect centers along four crystal axes forms an intrinsic coordinate system, enabling vector magnetometry within a single diamond crystal. While most vector magnetometers rely on a known bias magnetic field for full recovery of three-dimensional (3D) field information, employing external 3D Helmholtz coils or permanent magnets results in bulky, laboratory-bound setups, impeding miniaturization of the device. Here, a novel approach is presented that utilizes a fiber-integrated microscale coil at the fiber tip to generate a localized uniaxial magnetic field. The same fiber-tip coil is used in parallel for spin control by combining dc and microwave signals in a bias tee. To implement vector magnetometry using a uniaxial bias field, the orientation of the diamond crystal is preselected and then fully characterized by rotating a static magnetic field in three planes of rotation. The measurement of vector magnetic fields in the full solid angle is demonstrated with a shot-noise-limited sensitivity of 19.4 nT/Hz 1/2 and microscale spatial resolution while achieving a fiber sensor head cross section of less than 1 mm2
Using an optical fiber to both excite the nitrogen-vacancy (NV) center in diamond and collect its fluorescence is essential to build NV-based endoscope-type sensor. Such endoscope-type sensor can reach inaccessible fields for traditional NV-based sensors built by bulky optical components and extend the application areas. Since single NV's fluorescence is weak and can easily be buried in fluorescence from optical fiber core's oxide defects excited by the green laser, fixing a micrometer size diamond containing high-density NVs rather than a nanodiamond containing single NV or several NVs on the apex of an optical fiber to build an endoscope-type sensor is more implementable. Unfortunately, due to small numerical aperture (NA), most of the optical fibers have a low fluorescence collection efficiency, which limits the sensitivity and spatial resolution of the NV-based endoscope-type sensor. Here, using a tapered optical fiber (TOF) tip, we significantly improve the efficiency of the laser excitation and fluorescence collection of the NV ensembles in diamond. This could potentially enhance the sensitivity and spatial resolution of the NV-based endoscope-type sensor. Numerical calculations show that the TOF tip delivers a high NA and has a high NV excitation and fluorescence collection efficiency. Experiments demonstrate that such TOF tip can obtain up to over 7-fold excitation efficiency and over 15-fold fluorescence collection efficiency of that from a flat-ended fiber (non-TOF) tip.
Quantum sensors based on the nitrogen-vacancy (NV) center in diamond are leading platforms for high-sensitivity magnetometry with nanometer-scale resolution. State-of-the-art implementations, however, typically rely on bulky free-space optics or sacrifice spatial resolution to achieve high sensitivities. Here, we realize an integrated platform that overcomes this trade-off by fabricating monolithic whispering-gallery-mode cavities from a diamond chip containing a high density of NV centers and by evanescently coupling excitation to and photoluminescence from the cavity using a tapered optical fiber. Employing a lock-in-amplified Ramsey magnetometry scheme, we achieve a photon-shot-noise-limited DC sensitivity of 58 nT/Hz58\,\text{nT}/\sqrt{\text{Hz}}58nT/Hz​---the best sensitivity reported to date for a nanofabricated cavity-based magnetometer. The microscopic cavity size enables micrometer-scale spatial resolution and low-power operation, while fiber-coupling provides a path to scalable on-chip integration. Arrays of such sensors could enable NV-NMR spectroscopy of sub-nanoliter samples, new magnetic-gradient imaging architectures, and compact biosensing platforms.