The realization of high-precision quantum sensors based on cold atoms in space demands exceptional environmental control, particularly in maintaining ultra-high vacuum (UHV) conditions. We present the development of a quantum sensor for cold atom interferometry, with a focus on the design and performance of its UHV system. The sensor is designed for operation in microgravity environments, enabling long interrogation times and enhanced sensitivity for applications in fundamental physics, geodesy, and inertial navigation. One focus of this contribution is the setup and qualification of the optical windows, enabling UHV sealing and transmission of all needed laser frequencies, while fulfilling the optical requirements.
The realization of high-precision quantum sensors based on cold atoms in space demands exceptional environmental control, particularly in maintaining ultra-high vacuum (UHV) conditions. We present the development of a quantum sensor for cold atom interferometry, with a focus on the design and performance of its UHV system. The sensor is designed for operation in microgravity environments, enabling long interrogation times and enhanced sensitivity for applications in fundamental physics, geodesy, and inertial navigation. One focus of this contribution is the setup and qualification of the optical windows, enabling UHV sealing and transmission of all needed laser frequencies, while fulfilling the optical requirements.
Employing compact quantum sensors in field or in space (e.g., small satellites) implies demanding requirements on components and integration technologies. Within our work on integrated sensors, we develop miniaturized, ultra-stable optical setups for optical cooling and trapping of cold atomic gases. Besides challenging demands on alignment precision, and thermo-mechanical durability, we specifically address ultra-high vacuum (UHV) compatibility of our integration technologies and optical components. A prototype design of an UHV-compatible, crossed beam optical dipole trap setup and its application within a cold atomic quantum sensor is described. First qualification efforts on adhesive micro-integration technologies are presented. These tests are conducted in application-relevant geometries and material combinations common for micro-integrated optical setups. Adhesive aging will be investigated by thermal cycling or gamma radiation exposure. For vacuum compatibility testing, a versatile UHV testing system is currently being set up, enabling residual gas analysis and measurement of total gas rates down to 5•10-10mbar l/s at a base pressure of 10-11 mbar, exceeding the common ASTM E595 test.
Cooling atoms to Nano-Kelvin requires an ultra-high vacuum system with complex features, such as coated optical accesses, paramagnetic materials, or differential pumping stages. Furthermore, the sensitivity of atom interferometers, one promising application of ultra-cold atoms, scales with the free evolution time (T) of the cold ensembles. In order to increase T, microgravity becomes necessary. Hence, the development of reliable, miniaturized UHV systems with the capability to withstand the rough environment of microgravity platforms is a key task to pave the way for high performance cold atom instruments. In order to minimize such complex vacuum systems various tests have to be performed. For instance the measurement of outgassing rates for critical components inside the chamber and leakage rates of metal sealed windows allow a more detailed dimensioning of the vacuum pumps. In addition to the challenge of miniaturization, most of the microgravity platforms are linked to a rough thermal and mechanical environment. Vacuum pumps and seals are supposed to endure vibrations and loads of rocket launches or drop tower impacts. In the case of the sounding rocket mission MAIUS, the motors induced loads to the payload of up to 13 g. This talk presents the challenges for vacuum systems on microgravity platforms. Test beds for outgassing rate measurement, window sealing technologies and loaded CF flanges are shown and first results for the tests are given
Atom interferometry has hugely benefitted from advances made in cold atom physics over the past twenty years, and ultra-precise quantum sensors are now available for a wide range of applications [1]. In particular, cold atom interferometers have shown excellent performances in the field of acceleration and rotation measurements [2,3], and are foreseen as promising candidates for navigation, geophysics, geo-prospecting and tests of fundamental physics such as the Universality of Free Fall (UFF). In order to carry out a test of the UFF with atoms as test masses, one needs to compare precisely the accelerations of two atoms with different masses as they fall in the Earth’s gravitational field. The sensitivity of atom interferometers scales like the square of the time during which the atoms are in free fall, and on ground this interrogation time is limited by the size of the experimental setup to a fraction of a second. Sending an atom interferometer in space would allow for several seconds of excellent free-fall conditions, and tests of the UFF could be carried out with precisions as low as 10-15 [4]. However, cold atoms experiments rely on complex laser systems, which are needed to cool down and manipulate the atoms, and these systems are usually very sensitive to temperature fluctuations and vibrations. In addition, when operating an inertial sensor, vibrations are a major issue, as they deteriorate the performances of the instrument. This is why cold atom interferometers are usually used in ground based facilities, which provide stable enough environments. In order to carry out airborne or space-borne measurements, one has to design an instrument which is both compact and stable, and such that vibrations induced by the platform will not deteriorate the sensitivity of the sensor. We report on the operation of an atom interferometer on board a plane carrying out parabolic flights (Airbus A300 Zero-G, operated by Novespace). We have constructed a compact and stable laser setup, which is well suited for onboard applications. Our goal is to implement a dual-species Rb-K atom interferometer in order to carry out a test of the UFF in the plane. In this perspective, we are designing a dual-wavelength laser source, which will enable us to cool down and coherently manipulate the quantum states of both atoms. We have successfully tested a preliminary version of the source and obtained a double species magneto-optical trap (MOT).
Ultra-cold atoms have become indispensable in quantum sensing, quantum computing, and quantum communication applications, as well as in fundamental sciences. In quantum sensing, they enable precision measurements with outstanding sensitivities that can be of great benefit in navigation, geodesy, and fundamental physics applications. The sensitivity of the atom interferometers used herefore typically scales with the square of the interrogation time. Therefore, in atom interferometric measurements, one seeks ensembles that feature a particularly low internal kinetic energy and can thus be detected after a long time-of-flight. The lowest values are achieved using Bose-Einstein condensates in conjunction with delta-kick collimation, a technique for the collimation of the atomic wave function. Bose-Einstein condensation can be achieved using a multi-stage laser cooling scheme, followed by evaporative cooling, which finally brings the temperature down to the critical temperature, typically in the nanokelvin regime. In addition to the low thermal spread, microgravity enables particularly long observation times, as it avoids limitations of the interrogation time due to vacuum chamber constraints, which are present when falling freely under the influence of gravity. Additionally, microgravity enables measurements that are not possible under normal gravity conditions, such as buoyancy-free miscibility studies, truly uniform potentials, and advanced cold atom quantum memories, which are projected to feature unprecedented time-bandwidth products. For the preparation of a Bose-Einstein condensate, two techniques are widely used in science, namely magnetic traps and optical dipole traps. For microgravity missions, magnetic traps on atom chips have been used in nearly all setups so far due to their particularly low SWAP budget and high cold atom flux. In contrast, ground-based experiments often prefer optical traps due to their higher versatility, full optical access, and the absence of surfaces in proximity to the atoms, which is fundamental for precision measurements. Additionally, optical traps enable the manipulation of intra- and inter-species scattering lengths using Feshbach resonances. Compared to atom chip traps, they also feature an intrinsically better symmetry of the trapping potential, in theory leading to fewer aberrations in matter-wave optics. The latter could enable the generation of ensembles in the yet unreached femtokelvin regime using delta-kick collimation with fewer perturbations. This thesis is about the realization of a 1064nm optical dipole trap set up for the microgravity environment of the Bremen Drop Tower. It aims to highlight the advantages of optical traps in conjunction with microgravity and prepare optical trapping technology for use in future microgravity and space missions. The thesis describes the experimental setup, the direct loading process, the characterization of the optical potential, and the optimization and investigation of the evaporative cooling in the optical dipole trap. For the evaporation process, the influence of gravity is comprehensively investigated through analytical calculations and microgravity tests. Bose-Einstein condensation is demonstrated, proving the achievement of condensation through absorption imaging of the spatial distribution, tests on the free evolution of the ensemble, and investigation of the phase-space densities achieved. Up to (74 ± 4)% condensation of an ensemble featuring (30 000 ± 13 000) atoms at a kinetic temperature of (37 ± 3) nK is demonstrated. The evaporation shows high efficiency down to a 3 s evaporation time, while a critical phase-space density can be achieved within (1.29 ± 0.07) s using an even faster evaporation ramp. This opens the door to fundamental physics experiments on Bose-Einstein condensates in microgravity, as well as applications pursuing atomic ensembles with exceptionally low expansion velocities.
In recent years, quantum technology has attracted attention in inertial navigation, especially due to its extreme sensitivity to inertial forces and strong immunity to drifts, which plague conventional sensors. There are multiple groups around the world working on cold atom interferometry aiming to develop high sensitive inertial sensors for very high accuracy autonomous navigation. Recent advancements in micro-fabrication technologies have helped in development of robust and miniaturized atom interferometry based high performance inertial systems. These, in future, will pave way for autonomous satellite inertial navigation sensors based on cold atoms. Here we discuss the achievements towards realizing cold atom inertial sensors and their indomitable role as inertial sensors for future satellites. A detailed survey on the initiatives taken by different space agencies, their achievements and their plans to explore its potential in space are also discussed.
Quantum technology based on cold-atom interferometers is showing great promise for fields such as inertial sensing and fundamental physics. However, the best precision achievable on Earth is limited by the free-fall time of the atoms, and their full potential can only be realized in Space where interrogation times of many seconds will lead to unprecedented sensitivity. Various mission scenarios are presently being pursued, which plan to implement matter-waves inertial sensors to detect gravitational waves, to measure the Earth gravity field or to test fundamental physics such as the Equivalence Principle.We developed a cold atom sensor experiment adapted to microgravity platforms, especially the ZERO-G plane. To achieve a test of the Universality of Free Fall, we realize the first onboard operation of simultaneous ^{87}Rb - ^{39}K interferometers in the weightlessness environment produced during parabolic flight. The large vibration levels (10 ^{-2} g/Hz ^{1/2}), acceleration range and rotation rates (5 deg/s) during flight present significant technical challenges for atom interferometers. By hybridizing each atomic sensor with a common mechanical accelerometer, we achieve a sensitivity of 3.4 10 ^{-5} g per shot-more than 1600 times below the ambient vibration level onboard the aircraft. We demonstrate the capability of our dual-quantum sensor by measuring the Eötvös parameter with systematic-limited uncertainties of 3.0 10 ^{-4} during micro-gravity. This constitutes the first quantum test of the equivalence principle in a free falling vehicle. Our results can be extended to the trajectory of a satellite for future Space missions. We also achieved a simultaneous ^{87}Rb- ^{39}K interferometer on ground with a long term stability on the differential acceleration measurement around 5 10 ^{-8}g, limited by the fall of the atom clouds. To increase the interrogation time and the sensitivity, a ZERO-G simulator has been installed in our laboratory and allows our experiment to be in free fall during 500 ms every 12 seconds, to achieve highly repeatable measurements in microgravity. We expect to increase our short-term sensitivity by two orders of magnitude, and consequently reach a long-term measurement of the Eötvös parameter at the level of 10 ^{-11}.To benefit from the free fall of the experiment completely, it is necessary to produce atoms clouds with a reduced velocity dispersion. To reach this goal, we put ^{87}Rb atoms in an optical dipole trap supplied by a compact fiber laser compliant with onboard applications and decrease the optical power on a very controlled way to obtain evaporative cooling. Preliminary results of ultra-fast evaporative cooling (less than a few seconds) onboard the ZERO-G plane allowed us to reach a regime of temperature compliant with an interrogation time of the order of one second. This method and technology will be tested on the ZERO-G simulator as well.