Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

MIMS_v7.4.1_Multimodal_Instrument_for_Spin_Ensemble_Characterization

Walter Ayala

Published May 17, 2026• 0 citations
Publisher

Abstract

The design of the Multimodal Instrument for Spin Ensemble Characterization(MIMS v7.4.1) is presented. The instrument executes seven independent measure-ment protocols on solid-state spin ensembles, operating under controlled vacuum con-ditions to minimize environmental decoherence.• Standard Protocol: Multi-exponential relaxation dynamics.• RAE Protocol: Controlled interruption of entanglement.• TEBC Protocol: Response under magnetic field near the correlation loss threshold(effective phenomenological model).• PDE Protocol: Diagnosis of response patterns under magnetic constraint.• REU Protocol: Correlational restoration with synchronized pulses.• SBR Protocol: Edge-of-rupture sensor (regulated phenomenological model).• SBR-REU Protocol: Combined amplification and restoration mode.Eight sensor channels (expandable to nine with Mössbauer in Plan B) monitor fourspin ensembles. Entanglement operates in micro-windows (∼ 100 µs–1 ms) withineach macroscopic cycle.The vacuum chamber (< 10−5 mbar) eliminates collisional decoherence. PlanB incorporates Mössbauer for independent cross-validation.Computational simulation (Appendix E) validates the statistical architecture.All protocols achieve positive detection under controlled conditions. ChannelsCH4 (SQUID) and CH6 (SERF) dominate magnetometric sensitivity; secondarychannels provide instrumental veto, cross-validation, and pattern classification.Construction cost: $850,000–$5,000,000+ USD. Timeline: 66–78 months.

DOI
10.5281/zenodo.20258130

Related papers

The Silence Experiment: Multi-State Protocol for Detecting Consciousness-Dependent Quantum Decoherence in Shielded Environments

Clifton Bacon

This registration is the confirmatory analysis plan and full protocol for The Silence Experiment, a multi-participant Phase 0 investigation of whether specific, EEG-verified states of consciousness can systematically modulate the decoherence time (T₂) of a shielded room-temperature NV-center diamond quantum sensor. The protocol is documented in three companion Zenodo papers: The Silence Paradigm v11 — https://doi.org/10.5281/zenodo.20326258 The Silence Experiment v13 — https://doi.org/10.5281/zenodo.20325967 Design Specifications for a Five-Layer Shielded Chamber (TSP-ENG-001 V5) — https://doi.org/10.5281/zenodo.20326311 The design places experienced meditators inside a 3.0 m cubic five-layer shielded chamber (acoustic/thermal, hydrogen-annealed mu-metal magnetic, welded OFHC copper RF, pneumatic vibration isolation, aluminum structural Faraday cage). Cognitive state is the independent variable, operationalised as seven EEG-verified conditions C1–C7 ordered by descending cognitive excitation — C1 active cognition, C2 ordinary resting, C3 focused attention (Shamatha), C4 open monitoring (Vipassana), C5 non-directed openness, C6 Minimal Phenomenal Experience / luminous bare awareness, C7 cessation / objectless awareness — plus an empty-chamber instrumental baseline run as separate sessions. Real-time 64-channel wireless EEG verifies state attainment (EEG signature is the primary inclusion criterion for C6 and C7). Comprehensive synchronous environmental monitoring (SQUID magnetometers, fluxgate magnetometer, 3-axis accelerometer, Pt100 RTDs to ±0.001 K, RF, humidity, barometric pressure, acoustic SPL) is recorded via GPS-disciplined 10 MHz common time base for artifact-correlation analysis. The pre-registered primary analysis is a family of three tests: a Jonckheere–Terpstra ordered test on the C1 → C7 ordering, plus two orthogonal planned contrasts — Contrast 1 ([C6, C7] vs. [baseline, C1–C5]) and Contrast 2 (C7 vs. C6) — evaluated at family-wise α = 0.005 one-sided with Bonferroni correction (per-test α ≈ 0.00167), accompanied by a parallel Bayesian analysis with pre-specified Bayes Factor thresholds (BF > 10 strong, BF > 100 decisive). The threshold follows Benjamin et al. (2018) for novel discovery claims. The Phase 0 minimum detectable effect is d ≥ 0.4 on Contrast 1 at n = 50 sessions per condition. Analysis is outcome-blinded and conducted by an independent statistician who does not see condition labels until the locked dataset is delivered. Any positive primary result is subjected to artifact analysis against the full environmental channel set and requires independent replication by a non-affiliated laboratory before being treated as established. No data of any kind have been collected as of this update. All raw data, analysis code, and any deviations will be publicly deposited here with full transparency upon completion. Amendment history is visible in the Updates panel; v1 (April 2026 original), v2 (terminology), v3 (V9-aligned methodology), and v4 (V13-aligned, pending moderator approval) constitute the full version record.

•Jan 1, 2026•0 citations

Interaction-Enhanced Sensing in Solid-State Spin Ensembles

Haoyang Gao

Solid-state spin ensembles have emerged as a leading platform for micro- and nanoscale sensing, combining high sensitivity, nanoscale spatial resolution, and operation under ambient conditions. At high spin densities, magnetic dipole–dipole interactions typically limit sensing performance by reducing coherence, but can in principle be harnessed to enhance sensitivity. Realizing such interaction-enhanced sensing in practice, however, remains challenging due to the intrinsic anisotropy of dipolar interactions and the random spatial distribution of spins. This thesis presents a series of experimental works that culminate in a practical interaction-enhanced magnetometer based on ensembles of nitrogen-vacancy (NV) centers in diamond. Our approach is based on collective, one-axis-twisting-like (OAT-like) dynamics engineered from native dipolar interactions using controlled nanoscale spin textures, in combination with a dressed-state qubit encoding that significantly extends the sensor coherence time. These results open the door to practical deployment of interaction-enhanced quantum sensors for nanoscale biological imaging and material characterization.

•Jan 1, 2026•0 citations

Exploratory_Protocol_for_the_Unified_Coupling_Field_via_Silence_as_a_Quantum_Filter

Walter Ayala

The General Formalism of Experimental Detectability (FGDE v2.4) is applied tothe Silence Protocol to evaluate its feasibility with current and near-term (3–5 years)technology. The Silence Protocol operates within the FILTRATION paradigm,where the signal emerges by progressively eliminating noise sources. Three imple-mentation levels are identified: Level 1 (Passive Silence, viable today, 300–515 kUSD),Level 2 (Active Silence, viable in 2–3 years, 335–590 kUSD), and Level 3 (ResonantSilence, viable in 5+ years, 605 kUSD–1.22 MUSD). Level 1 enables four publish-able experiments with current technology: measurement of yield in absolute silence,search for excess EM noise, measurement of nuclear spin decoherence, and temper-ature sweep searching for anti-Arrhenius behavior.Version 2.4: Critical corrections are incorporated based on independent review:(i) quantification of D-D pair density in 2 nm nanocavities and its impact on yieldlimits, (ii) reference calculation of decoherence time T2 by D-D nuclear dipolar cou-pling, (iii) SQUID calibration chain with uncertainty propagation, (iv) structuralequivalence analysis TiH2:Pd vs. TiD2:Pd, and (v) exploration of alternatives toPW laser for Level 3. A rigorous analysis of formal coherence, mathematical feasi-bility, synchronization, calibration, exploratory methodology, instrumentation, andrisk matrix with quantified failure probability for PW facility transport is included.Appendix C (New): A rigorous numerical simulation of Level 1 is presented,validating the protocol predictions. The simulation demonstrates that the UCFproduces consistent anomalies across all four experiments (4.2σ to 136.9σ), satisfyingall falsifiability criteria and justifying escalation to Level 2.

•Jul 8, 2026•0 citations

Analog_Quantum_Simulator_of_Spin_Models

Walter Ayala

Version 6.1 develops an integral framework for an analog quantum simulator of spin modelsbased on programmable superconducting-qubit arrays.The principal objective is not merely to construct a quantum device, but to establish atraceable mappingcontrol parameters −→ Hreal −→ quantum evolution −→ observables −→ classical reference.The framework supports transverse-field Ising, XY, XXZ, Heisenberg, long-range, anddisordered spin Hamiltonians.Version 6.1 introduces an explicit Hamiltonian- identification layer between hardwarecalibration and scientific validation.The realized Hamiltonian is decomposed into target terms, static calibration errors, dynamiccontrol errors, crosstalk, leakage, decoherence, and residual unwanted interactions.Validation is organized hierarchically:1. hardware calibration;2. Hamiltonian identification;3. state-preparation validation;4. readout calibration;5. static observable validation;6. dynamical observable validation;7. finite-size benchmarking;8. statistical equivalence testing;9. cross-device reproducibility;10. independent analytical reproduction. The statistical framework replaces the inadequate criterion of “statistical significance ofagreement” with an equivalence framework based on preregistered tolerances.The primary hypothesis is therefore formulated using two one-sided tests (TOST) or anequivalent confidence interval criterion:|∆O| < ϵO.Version 6.1 additionally specifies:• a supplementary Bayesian posterior probability of equivalence as a robustness check;• an explicit distinction between engineering no-go and physical falsification.The framework also specifies negative controls, positive controls, blind analysis, lockedanalysis code, exclusion rules, uncertainty propagation, data provenance, and reproducibilityrequirements.No experimental result or quantum advantage is claimed.

•Sep 24, 2026•0 citations

High-density optical quantum sensors with pulsed probe read-out for correlated spin-noise reduction

Igor Savukov, Young Jin Kim

Abstract Optical quantum sensors based on alkali-metal atoms enable highly sensitive magnetic-field measurements in warm vapor. Their performance can become limited by intrinsic spin noise once technical noise sources are sufficiently suppressed. Characterizing temporal spin correlations is therefore important both for optimizing sensor sensitivity and for investigating quantum-enhanced sensing protocols. Here we investigate correlated spin fluctuations in a radio-frequency optical quantum sensor based on a high-density potassium vapor cell using pulsed probe readout. Orthogonal pump and probe beams establish and detect the spin polarization, while a bias magnetic field defines the sensing frequency and the probe pulses are synchronized electronically with the driven spin response. The protocol combines periodic probing, phase cycling, and variable-delay window subtraction. Phase cycling suppresses reproducible probe-induced coherent transients between experimental cycles, whereas window subtraction probes correlations between two measurements within the same cycle. The measured difference noise increases toward an asymptotic value with delay, demonstrating temporal correlations in the processed signal. This behavior is compatible with correlations expected from a conditional quantum non-demolition mechanism, but the present experiment does not independently establish spin squeezing below the standard quantum limit or uniquely exclude residual technical correlations. The protocol provides a practical framework for studying correlated noise in warm-vapor radio-frequency optical quantum sensors.

arXiv:2608.25077•Scientific Reports•Oct 6, 2026•0 citations

Squeezed_Superconducting_Qubit_Magnetic_Sensor

Walter Ayala

This document presents Version 6.1 of a proposed quantum magnetic sensor based on acollectively prepared, spin-squeezed ensemble of superconducting qubits.The central objective is to determine, experimentally and reproducibly, whether quantumstate preparation can improve magnetic-field estimation relative to a matched unsqueezedsuperconducting-qubit reference operated with the same device, readout chain, resource budget,and total cycle time.A critical physical refinement of the present version is that a superconducting qubit is notassumed to couple to magnetic field through the bare electron gyromagnetic ratio.Instead, the magnetic transduction coefficient is defined operationally asκB,i =⃓⃓⃓⃓∂ωi∂B⃓⃓⃓⃓,or, for flux-mediated devices,κB,i =⃓⃓⃓⃓∂ωi∂Φi⃓⃓⃓⃓Mi,where Miis the effective field-to-flux coupling coefficient.This formulation permits transmon, SQUID-loop, fluxonium, or related architectures withoutconflating artificial-qubit dynamics with physical electron-spin Zeeman coupling.The quantum-state resource is characterized using the optimized Wineland spin-squeezingparameterξ2R =N minn⊥ Var(Sn⊥ )|⟨S⟩|2.Values below unity constitute a metrological spin-squeezing criterion under the statedcollective-spin model.The primary metrological endpoint is not ξ−1R alone.Instead, the proposed experiment directly compares the measured magnetic-field sensitivityper square root bandwidth of the squeezed protocol against a matched coherent/unsqueezedprotocol:Gpair =ηB,cohηB,sq. The principal confirmatory criterion is that the preregistered 95% confidence interval forthe paired gain exclude unity after accounting for preparation overhead, contrast, decoherence,readout noise, calibration uncertainty, device-to-device variation, and cooldown-to-cooldownvariation.The framework includes Hamiltonian modeling, collective squeezing, Ramsey interferometry,classical and quantum Fisher information, open-system dynamics, magnetic transductioncalibration, null tests, blind analysis, preregistration, hierarchical statistics, uncertainty budgets,replication criteria, falsification rules, data schemas, and a reproducible Python referenceimplementation.No experimental result is claimed.

•Sep 24, 2026•0 citations
The design of the Multimodal Instrument for Spin Ensemble Characterization(MIMS v7.4.1) is presented. The instrument executes seven independent measure-ment protocols on solid-state spin ensembles, operating under controlled vacuum con-ditions to minimize environmental decoherence.• Standard Protocol: Multi-exponential relaxation dynamics.• RAE Protocol: Controlled interruption of entanglement.• TEBC Protocol: Response under magnetic field near the correlation loss threshold(effective phenomenological model).• PDE Protocol: Diagnosis of response patterns under magnetic constraint.• REU Protocol: Correlational restoration with synchronized pulses.• SBR Protocol: Edge-of-rupture sensor (regulated phenomenological model).• SBR-REU Protocol: Combined amplification and restoration mode.Eight sensor channels (expandable to nine with Mössbauer in Plan B) monitor fourspin ensembles. Entanglement operates in micro-windows (∼ 100 µs–1 ms) withineach macroscopic cycle.The vacuum chamber (< 10−5 mbar) eliminates collisional decoherence. PlanB incorporates Mössbauer for independent cross-validation.Computational simulation (Appendix E) validates the statistical architecture.All protocols achieve positive detection under controlled conditions. ChannelsCH4 (SQUID) and CH6 (SERF) dominate magnetometric sensitivity; secondarychannels provide instrumental veto, cross-validation, and pattern classification.Construction cost: 850,000–850,000–850,000–5,000,000+ USD. Timeline: 66–78 months.
This registration is the confirmatory analysis plan and full protocol for The Silence Experiment, a multi-participant Phase 0 investigation of whether specific, EEG-verified states of consciousness can systematically modulate the decoherence time (T₂) of a shielded room-temperature NV-center diamond quantum sensor. The protocol is documented in three companion Zenodo papers: The Silence Paradigm v11 — https://doi.org/10.5281/zenodo.20326258 The Silence Experiment v13 — https://doi.org/10.5281/zenodo.20325967 Design Specifications for a Five-Layer Shielded Chamber (TSP-ENG-001 V5) — https://doi.org/10.5281/zenodo.20326311 The design places experienced meditators inside a 3.0 m cubic five-layer shielded chamber (acoustic/thermal, hydrogen-annealed mu-metal magnetic, welded OFHC copper RF, pneumatic vibration isolation, aluminum structural Faraday cage). Cognitive state is the independent variable, operationalised as seven EEG-verified conditions C1–C7 ordered by descending cognitive excitation — C1 active cognition, C2 ordinary resting, C3 focused attention (Shamatha), C4 open monitoring (Vipassana), C5 non-directed openness, C6 Minimal Phenomenal Experience / luminous bare awareness, C7 cessation / objectless awareness — plus an empty-chamber instrumental baseline run as separate sessions. Real-time 64-channel wireless EEG verifies state attainment (EEG signature is the primary inclusion criterion for C6 and C7). Comprehensive synchronous environmental monitoring (SQUID magnetometers, fluxgate magnetometer, 3-axis accelerometer, Pt100 RTDs to ±0.001 K, RF, humidity, barometric pressure, acoustic SPL) is recorded via GPS-disciplined 10 MHz common time base for artifact-correlation analysis. The pre-registered primary analysis is a family of three tests: a Jonckheere–Terpstra ordered test on the C1 → C7 ordering, plus two orthogonal planned contrasts — Contrast 1 ([C6, C7] vs. [baseline, C1–C5]) and Contrast 2 (C7 vs. C6) — evaluated at family-wise α = 0.005 one-sided with Bonferroni correction (per-test α ≈ 0.00167), accompanied by a parallel Bayesian analysis with pre-specified Bayes Factor thresholds (BF > 10 strong, BF > 100 decisive). The threshold follows Benjamin et al. (2018) for novel discovery claims. The Phase 0 minimum detectable effect is d ≥ 0.4 on Contrast 1 at n = 50 sessions per condition. Analysis is outcome-blinded and conducted by an independent statistician who does not see condition labels until the locked dataset is delivered. Any positive primary result is subjected to artifact analysis against the full environmental channel set and requires independent replication by a non-affiliated laboratory before being treated as established. No data of any kind have been collected as of this update. All raw data, analysis code, and any deviations will be publicly deposited here with full transparency upon completion. Amendment history is visible in the Updates panel; v1 (April 2026 original), v2 (terminology), v3 (V9-aligned methodology), and v4 (V13-aligned, pending moderator approval) constitute the full version record.
Solid-state spin ensembles have emerged as a leading platform for micro- and nanoscale sensing, combining high sensitivity, nanoscale spatial resolution, and operation under ambient conditions. At high spin densities, magnetic dipole–dipole interactions typically limit sensing performance by reducing coherence, but can in principle be harnessed to enhance sensitivity. Realizing such interaction-enhanced sensing in practice, however, remains challenging due to the intrinsic anisotropy of dipolar interactions and the random spatial distribution of spins. This thesis presents a series of experimental works that culminate in a practical interaction-enhanced magnetometer based on ensembles of nitrogen-vacancy (NV) centers in diamond. Our approach is based on collective, one-axis-twisting-like (OAT-like) dynamics engineered from native dipolar interactions using controlled nanoscale spin textures, in combination with a dressed-state qubit encoding that significantly extends the sensor coherence time. These results open the door to practical deployment of interaction-enhanced quantum sensors for nanoscale biological imaging and material characterization.
The General Formalism of Experimental Detectability (FGDE v2.4) is applied tothe Silence Protocol to evaluate its feasibility with current and near-term (3–5 years)technology. The Silence Protocol operates within the FILTRATION paradigm,where the signal emerges by progressively eliminating noise sources. Three imple-mentation levels are identified: Level 1 (Passive Silence, viable today, 300–515 kUSD),Level 2 (Active Silence, viable in 2–3 years, 335–590 kUSD), and Level 3 (ResonantSilence, viable in 5+ years, 605 kUSD–1.22 MUSD). Level 1 enables four publish-able experiments with current technology: measurement of yield in absolute silence,search for excess EM noise, measurement of nuclear spin decoherence, and temper-ature sweep searching for anti-Arrhenius behavior.Version 2.4: Critical corrections are incorporated based on independent review:(i) quantification of D-D pair density in 2 nm nanocavities and its impact on yieldlimits, (ii) reference calculation of decoherence time T2 by D-D nuclear dipolar cou-pling, (iii) SQUID calibration chain with uncertainty propagation, (iv) structuralequivalence analysis TiH2:Pd vs. TiD2:Pd, and (v) exploration of alternatives toPW laser for Level 3. A rigorous analysis of formal coherence, mathematical feasi-bility, synchronization, calibration, exploratory methodology, instrumentation, andrisk matrix with quantified failure probability for PW facility transport is included.Appendix C (New): A rigorous numerical simulation of Level 1 is presented,validating the protocol predictions. The simulation demonstrates that the UCFproduces consistent anomalies across all four experiments (4.2σ to 136.9σ), satisfyingall falsifiability criteria and justifying escalation to Level 2.
Version 6.1 develops an integral framework for an analog quantum simulator of spin modelsbased on programmable superconducting-qubit arrays.The principal objective is not merely to construct a quantum device, but to establish atraceable mappingcontrol parameters −→ Hreal −→ quantum evolution −→ observables −→ classical reference.The framework supports transverse-field Ising, XY, XXZ, Heisenberg, long-range, anddisordered spin Hamiltonians.Version 6.1 introduces an explicit Hamiltonian- identification layer between hardwarecalibration and scientific validation.The realized Hamiltonian is decomposed into target terms, static calibration errors, dynamiccontrol errors, crosstalk, leakage, decoherence, and residual unwanted interactions.Validation is organized hierarchically:1. hardware calibration;2. Hamiltonian identification;3. state-preparation validation;4. readout calibration;5. static observable validation;6. dynamical observable validation;7. finite-size benchmarking;8. statistical equivalence testing;9. cross-device reproducibility;10. independent analytical reproduction. The statistical framework replaces the inadequate criterion of “statistical significance ofagreement” with an equivalence framework based on preregistered tolerances.The primary hypothesis is therefore formulated using two one-sided tests (TOST) or anequivalent confidence interval criterion:|∆O| < ϵO.Version 6.1 additionally specifies:• a supplementary Bayesian posterior probability of equivalence as a robustness check;• an explicit distinction between engineering no-go and physical falsification.The framework also specifies negative controls, positive controls, blind analysis, lockedanalysis code, exclusion rules, uncertainty propagation, data provenance, and reproducibilityrequirements.No experimental result or quantum advantage is claimed.
Abstract Optical quantum sensors based on alkali-metal atoms enable highly sensitive magnetic-field measurements in warm vapor. Their performance can become limited by intrinsic spin noise once technical noise sources are sufficiently suppressed. Characterizing temporal spin correlations is therefore important both for optimizing sensor sensitivity and for investigating quantum-enhanced sensing protocols. Here we investigate correlated spin fluctuations in a radio-frequency optical quantum sensor based on a high-density potassium vapor cell using pulsed probe readout. Orthogonal pump and probe beams establish and detect the spin polarization, while a bias magnetic field defines the sensing frequency and the probe pulses are synchronized electronically with the driven spin response. The protocol combines periodic probing, phase cycling, and variable-delay window subtraction. Phase cycling suppresses reproducible probe-induced coherent transients between experimental cycles, whereas window subtraction probes correlations between two measurements within the same cycle. The measured difference noise increases toward an asymptotic value with delay, demonstrating temporal correlations in the processed signal. This behavior is compatible with correlations expected from a conditional quantum non-demolition mechanism, but the present experiment does not independently establish spin squeezing below the standard quantum limit or uniquely exclude residual technical correlations. The protocol provides a practical framework for studying correlated noise in warm-vapor radio-frequency optical quantum sensors.
This document presents Version 6.1 of a proposed quantum magnetic sensor based on acollectively prepared, spin-squeezed ensemble of superconducting qubits.The central objective is to determine, experimentally and reproducibly, whether quantumstate preparation can improve magnetic-field estimation relative to a matched unsqueezedsuperconducting-qubit reference operated with the same device, readout chain, resource budget,and total cycle time.A critical physical refinement of the present version is that a superconducting qubit is notassumed to couple to magnetic field through the bare electron gyromagnetic ratio.Instead, the magnetic transduction coefficient is defined operationally asκB,i =⃓⃓⃓⃓∂ωi∂B⃓⃓⃓⃓,or, for flux-mediated devices,κB,i =⃓⃓⃓⃓∂ωi∂Φi⃓⃓⃓⃓Mi,where Miis the effective field-to-flux coupling coefficient.This formulation permits transmon, SQUID-loop, fluxonium, or related architectures withoutconflating artificial-qubit dynamics with physical electron-spin Zeeman coupling.The quantum-state resource is characterized using the optimized Wineland spin-squeezingparameterξ2R =N minn⊥ Var(Sn⊥ )|⟨S⟩|2.Values below unity constitute a metrological spin-squeezing criterion under the statedcollective-spin model.The primary metrological endpoint is not ξ−1R alone.Instead, the proposed experiment directly compares the measured magnetic-field sensitivityper square root bandwidth of the squeezed protocol against a matched coherent/unsqueezedprotocol:Gpair =ηB,cohηB,sq. The principal confirmatory criterion is that the preregistered 95% confidence interval forthe paired gain exclude unity after accounting for preparation overhead, contrast, decoherence,readout noise, calibration uncertainty, device-to-device variation, and cooldown-to-cooldownvariation.The framework includes Hamiltonian modeling, collective squeezing, Ramsey interferometry,classical and quantum Fisher information, open-system dynamics, magnetic transductioncalibration, null tests, blind analysis, preregistration, hierarchical statistics, uncertainty budgets,replication criteria, falsification rules, data schemas, and a reproducible Python referenceimplementation.No experimental result is claimed.