Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Proposal and evaluation of the statistical testing using the weak value amplification

友紀 須佐, Yuki Susa, Saki Tanaka

Published Aug 1, 2014• 0 citations
OpenAlex

Related papers

Statistical hypothesis testing by weak-value amplification: Proposal and evaluation

Yuki Susa, Saki Tanaka

We study the detection capability of the weak-value amplification on the basis of the statistical hypothesis testing. We propose a reasonable testing method in the physical and statistical senses to find that the weak measurement with the large weak value has the advantage to increase the detection power and to reduce the possibility of missing the presence of interaction. We enhance the physical understanding of the weak value and mathematically establish the significance of the weak-value amplification. Our present work overcomes the critical dilemma of the weak-value amplification that the larger the amplification is, the smaller the number of data becomes, because the statistical hypothesis testing works even for a small number of data. This is contrasted with the parameter estimation by the weak-value amplification in the literature which requires a large number of data.

arXiv:1502.06334•Physical Review A•Jul 16, 2015•11 citations

Progress and perspectives on weak-value amplification

Liang Xu, Lijian Zhang

arXiv:2407.10087•Progress in Quantum Electronics•Jun 8, 2024•16 citations

Weak value amplification considered harmful

Christopher Ferrie, Joshua Combes

Bulletin of the American Physical Society•Mar 6, 2014•0 citations

Physical description of statistical hypothesis testing for a weak-value-amplification experiment using a birefringent crystal

Yuki Susa

We investigate the weak measurement experiment demonstrated by Ritchie et al. [N. W. M. Ritchie, J. G. Story, and R. G. Hulet, Phys. Rev. Lett. 66, 1107 (1991)] from the viewpoint of the statistical hypothesis testing for the weak-value amplification proposed by Susa and Tanaka [Y. Susa and S. Tanaka, Phys. Rev. A 92, 012112 (2015)]. We conclude that the weak-value amplification is a better method to determine whether the crystal used in the experiment is birefringent than the measurement without postselection, when the angles of two polarizers are almost orthogonal. This result gives a physical description and intuition of the hypothesis testing and supports the experimental usefulness of the weak-value amplification.

arXiv:1505.07199•Physical Review A•Aug 20, 2015•3 citations

Influence of environmental noise on the weak value amplification

Xuannmin Zhu, Yu-Xiang Zhang

arXiv:1505.01911•Quantum Information Processing•May 18, 2016•4 citations

Autocorrelative weak-value amplification and simulating the protocol under strong Gaussian noise

Jing-Hui Huang, Xiangyun Hu, Adetunmise C. Dada +4 more

By choosing more orthogonality between preselection and postselection states, one can significantly improve the sensitivity in general optical quantum metrology based on the weak-value amplification (WVA) approach. However, increasing the orthogonality decreases the probability of detecting photons and makes the weak measurement difficult, especially when the weak measurement is disturbed by strong noise and the pointer is drowned in noise with a negative-decibel signal-to-noise ratio (SNR). In this article we introduce and numerically evaluate a modified weak-measurement protocol with a temporal pointer, namely, the autocorrelative weak-value amplification (AWVA) approach. Specifically, a small longitudinal time delay (tiny phase shift) $\ensuremath{\tau}$ of a Gaussian pulse is measured by implementing two simultaneous autocorrelative weak measurements under Gaussian white noise with different SNRs. The small quantities $\ensuremath{\tau}$ are obtained by measuring the autocorrelation coefficient of the pulses instead of fitting the shift of the mean value of the probe in the standard WVA technique. Simulation results show that the AWVA approach outperforms the standard WVA technique in the time domain with smaller statistical errors, remarkably increasing the precision of weak measurement under a strong noise background.

arXiv:2203.15231•Physical Review A•Nov 3, 2022•9 citations
We study the detection capability of the weak-value amplification on the basis of the statistical hypothesis testing. We propose a reasonable testing method in the physical and statistical senses to find that the weak measurement with the large weak value has the advantage to increase the detection power and to reduce the possibility of missing the presence of interaction. We enhance the physical understanding of the weak value and mathematically establish the significance of the weak-value amplification. Our present work overcomes the critical dilemma of the weak-value amplification that the larger the amplification is, the smaller the number of data becomes, because the statistical hypothesis testing works even for a small number of data. This is contrasted with the parameter estimation by the weak-value amplification in the literature which requires a large number of data.
We investigate the weak measurement experiment demonstrated by Ritchie et al. [N. W. M. Ritchie, J. G. Story, and R. G. Hulet, Phys. Rev. Lett. 66, 1107 (1991)] from the viewpoint of the statistical hypothesis testing for the weak-value amplification proposed by Susa and Tanaka [Y. Susa and S. Tanaka, Phys. Rev. A 92, 012112 (2015)]. We conclude that the weak-value amplification is a better method to determine whether the crystal used in the experiment is birefringent than the measurement without postselection, when the angles of two polarizers are almost orthogonal. This result gives a physical description and intuition of the hypothesis testing and supports the experimental usefulness of the weak-value amplification.
By choosing more orthogonality between preselection and postselection states, one can significantly improve the sensitivity in general optical quantum metrology based on the weak-value amplification (WVA) approach. However, increasing the orthogonality decreases the probability of detecting photons and makes the weak measurement difficult, especially when the weak measurement is disturbed by strong noise and the pointer is drowned in noise with a negative-decibel signal-to-noise ratio (SNR). In this article we introduce and numerically evaluate a modified weak-measurement protocol with a temporal pointer, namely, the autocorrelative weak-value amplification (AWVA) approach. Specifically, a small longitudinal time delay (tiny phase shift) $\ensuremath{\tau}$ of a Gaussian pulse is measured by implementing two simultaneous autocorrelative weak measurements under Gaussian white noise with different SNRs. The small quantities $\ensuremath{\tau}$ are obtained by measuring the autocorrelation coefficient of the pulses instead of fitting the shift of the mean value of the probe in the standard WVA technique. Simulation results show that the AWVA approach outperforms the standard WVA technique in the time domain with smaller statistical errors, remarkably increasing the precision of weak measurement under a strong noise background.