Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1502.06334 · Physical Review A

Statistical hypothesis testing by weak-value amplification: Proposal and evaluation

Yuki Susa, Saki Tanaka

Published Jul 16, 2015• 11 citations
arXivHTMLPDF

Abstract

We study the detection capability of the weak-value amplification on the basis of the statistical hypothesis testing. We propose a reasonable testing method in the physical and statistical senses to find that the weak measurement with the large weak value has the advantage to increase the detection power and to reduce the possibility of missing the presence of interaction. We enhance the physical understanding of the weak value and mathematically establish the significance of the weak-value amplification. Our present work overcomes the critical dilemma of the weak-value amplification that the larger the amplification is, the smaller the number of data becomes, because the statistical hypothesis testing works even for a small number of data. This is contrasted with the parameter estimation by the weak-value amplification in the literature which requires a large number of data.

DOI
10.1103/physreva.92.012112

Related papers

Physical description of statistical hypothesis testing for a weak-value-amplification experiment using a birefringent crystal

Yuki Susa

We investigate the weak measurement experiment demonstrated by Ritchie et al. [N. W. M. Ritchie, J. G. Story, and R. G. Hulet, Phys. Rev. Lett. 66, 1107 (1991)] from the viewpoint of the statistical hypothesis testing for the weak-value amplification proposed by Susa and Tanaka [Y. Susa and S. Tanaka, Phys. Rev. A 92, 012112 (2015)]. We conclude that the weak-value amplification is a better method to determine whether the crystal used in the experiment is birefringent than the measurement without postselection, when the angles of two polarizers are almost orthogonal. This result gives a physical description and intuition of the hypothesis testing and supports the experimental usefulness of the weak-value amplification.

arXiv:1505.07199•Physical Review A•Aug 20, 2015•3 citations

Weak Value Amplification is Suboptimal for Estimation and Detection

Christopher Ferrie, Joshua Combes

We show by using statistically rigorous arguments that the technique of weak value amplification does not perform better than standard statistical techniques for the tasks of single parameter estimation and signal detection. Specifically, we prove that postselection, a necessary ingredient for weak value amplification, decreases estimation accuracy and, moreover, arranging for anomalously large weak values is a suboptimal strategy. In doing so, we explicitly provide the optimal estimator, which in turn allows us to identify the optimal experimental arrangement to be the one in which all outcomes have equal weak values (all as small as possible) and the initial state of the meter is the maximal eigenvalue of the square of the system observable. Finally, we give precise quantitative conditions for when weak measurement (measurements without postselection or anomalously large weak values) can mitigate the effect of uncharacterized technical noise in estimation.

arXiv:1307.4016•Physical Review Letters•Jan 31, 2014•218 citations

Weak values considered harmful

Christopher Ferrie, Joshua Combes

We show using statistically rigorous arguments that the technique of weak value amplification (WVA) does not perform better than standard statistical techniques for the tasks of single parameter estimation and signal detection. Specifically we prove that post-selection, a necessary ingredient for WVA, decreases estimation accuracy and, moreover, arranging for anomalously large weak values is a suboptimal strategy. In doing so, we explicitly provide the optimal estimator, which in turn allows us to identify the optimal experimental arrangement to be the one in which all outcomes have equal weak values (all as small as possible) and the initial state of the meter is the maximal eigenvalue of the square of the system observable. Finally, we give precise quantitative conditions for when weak measurement (measurements without post-selection or anomalously large weak values) can mitigate the effect of uncharacterized technical noise in estimation.

•Jul 15, 2013•4 citations

Weak Values and Balanced Homodyne Detection Working Together

Julián Martínez-Rincón, Wei-Tao Liu, Gerardo I. Viza +1 more

We present a metrological technique which, without discarding of data, resembles a larger anomalous amplification than weak-value-amplification (WVA). The protocol surpasses WVA techniques by amplifying an almost-balanced homodyne signal.

Frontiers in Optics•Jan 1, 2016•0 citations

Weak-measurement-enhanced Metrology in the Presence of CCD Noise and Saturation

Liang Xu, Zexuan Liu, Lijian Zhang

We experimentally demonstrate that the measurement using weak value amplification offers metrological advantages over the conventional measurement in the presence of classical noise and detection saturation with a generic scientific CCD.

Frontiers in Optics•Jan 1, 2018•2 citations

Proposal and evaluation of the statistical testing using the weak value amplification

友紀 須佐, Yuki Susa, Saki Tanaka

•Aug 1, 2014•0 citations
We study the detection capability of the weak-value amplification on the basis of the statistical hypothesis testing. We propose a reasonable testing method in the physical and statistical senses to find that the weak measurement with the large weak value has the advantage to increase the detection power and to reduce the possibility of missing the presence of interaction. We enhance the physical understanding of the weak value and mathematically establish the significance of the weak-value amplification. Our present work overcomes the critical dilemma of the weak-value amplification that the larger the amplification is, the smaller the number of data becomes, because the statistical hypothesis testing works even for a small number of data. This is contrasted with the parameter estimation by the weak-value amplification in the literature which requires a large number of data.
We investigate the weak measurement experiment demonstrated by Ritchie et al. [N. W. M. Ritchie, J. G. Story, and R. G. Hulet, Phys. Rev. Lett. 66, 1107 (1991)] from the viewpoint of the statistical hypothesis testing for the weak-value amplification proposed by Susa and Tanaka [Y. Susa and S. Tanaka, Phys. Rev. A 92, 012112 (2015)]. We conclude that the weak-value amplification is a better method to determine whether the crystal used in the experiment is birefringent than the measurement without postselection, when the angles of two polarizers are almost orthogonal. This result gives a physical description and intuition of the hypothesis testing and supports the experimental usefulness of the weak-value amplification.
We show by using statistically rigorous arguments that the technique of weak value amplification does not perform better than standard statistical techniques for the tasks of single parameter estimation and signal detection. Specifically, we prove that postselection, a necessary ingredient for weak value amplification, decreases estimation accuracy and, moreover, arranging for anomalously large weak values is a suboptimal strategy. In doing so, we explicitly provide the optimal estimator, which in turn allows us to identify the optimal experimental arrangement to be the one in which all outcomes have equal weak values (all as small as possible) and the initial state of the meter is the maximal eigenvalue of the square of the system observable. Finally, we give precise quantitative conditions for when weak measurement (measurements without postselection or anomalously large weak values) can mitigate the effect of uncharacterized technical noise in estimation.
We show using statistically rigorous arguments that the technique of weak value amplification (WVA) does not perform better than standard statistical techniques for the tasks of single parameter estimation and signal detection. Specifically we prove that post-selection, a necessary ingredient for WVA, decreases estimation accuracy and, moreover, arranging for anomalously large weak values is a suboptimal strategy. In doing so, we explicitly provide the optimal estimator, which in turn allows us to identify the optimal experimental arrangement to be the one in which all outcomes have equal weak values (all as small as possible) and the initial state of the meter is the maximal eigenvalue of the square of the system observable. Finally, we give precise quantitative conditions for when weak measurement (measurements without post-selection or anomalously large weak values) can mitigate the effect of uncharacterized technical noise in estimation.