Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Highly sensitive macro-scale diamond magnetometer operated by dynamical decoupling sequence with coplanar waveguide resonator

雄太 増山, Y. MASUYAMA, 皓介 水野, Kosuke Mizuno, 勇斗 小澤, Hayato Ozawa, 整 石綿, Hitoshi Ishiwata, 孝之 岩崎, T. Ohshima, 睦子 波多野, T. Iwasaki, Mutsuko Hatano, M. Hatano

Published May 1, 2018• 0 citations
OpenAlex

Related papers

Development of diamond quantum magnetometer module using coplanar waveguide

雄太 増山, Y. MASUYAMA, 孝之 岩崎 +4 more

•Feb 1, 2019•0 citations

Development of highly sensitive diamond quantum magnetometer using photonic structures

晃佑 髙田

•Mar 24, 2026•0 citations

Extending coherence time of macro-scale diamond magnetometer by dynamical decoupling with coplanar waveguide resonator

Y. MASUYAMA, Kosuke Mizuno, Hayato Ozawa +5 more

Ultimate sensitivity for quantum magnetometry using nitrogen-vacancy (NV) centers in a diamond is limited by a number of NV centers and coherence time. Microwave irradiation with a high and homogeneous power density for a large detection volume is necessary to achieve a highly sensitive magnetometer. Here, we demonstrate a microwave resonator to enhance the power density of the microwave field and an optical system with a detection volume of 1.4 × 10−3 mm3. The strong microwave field enables us to achieve 48 ns Rabi oscillation which is sufficiently faster than the phase relaxation time of NV centers. This system combined with a decoupling pulse sequence, XY16, extends the spin coherence time (T2) up to 27 times longer than that with a spin echo method. Consequently, we obtained an AC magnetic field sensitivity of 10.8 pt/Hz using the dynamical decoupling pulse sequence.

arXiv:1805.10725•Review of Scientific Instruments•Dec 1, 2018•38 citations

Sensitivity improvement of a single-NV diamond magnetometer using a chiral waveguide

Kosuke Takada, Ryota Katsumi, Takashi Yatsui

A single nitrogen-vacancy (NV) center in diamond is utilized to perform nanoscale magnetic measurements. However, the low contrast and poor collection efficiency of spin-dependent emitted photons limited the instrument sensitivity to approximately several nT/Hz. Here, we design a diamond magnetometer based on a chiral waveguide. We numerically demonstrate that the proposed device achieves a sensitivity of 170 pT/Hz owing to near-unity contrast and efficient photon collection. We also confirm that the device sensitivity is robust against position misalignment and dipole misorientation of an NV center. The proposed approach will enable the construction of a highly-sensitive magnetometer with high spatial resolution.

Optics Express•Dec 18, 2023•4 citations

High-dynamic-range magnetometry with a single electronic spin in diamond

Naufer Nusran, M. Ummal Momeen, M. V. Gurudev Dutt

Nature Nanotechnology•Dec 18, 2011•85 citations

Spin ensemble-based AC magnetometry using concatenated dynamical decoupling at low temperatures

Demitry Farfurnik, A Jarmola, D Budker +1 more

Abstract Ensembles of nitrogen-vacancy centers in diamond are widely used as AC magnetometers. While such measurements are usually performed using standard (XY) dynamical decoupling (DD) protocols at room temperature, we study the sensitivities achieved by utilizing various DD protocols, for measuring magnetic AC fields at frequencies in the 10–250 kHz range, at room temperature and 77 K. By performing measurements on an isotopically pure 12 C sample, we find that the Carr-Purcell–Meiboom-Gill protocol, which is not robust against pulse imperfections, is less efficient for magnetometry than robust XY-based sequences. The concatenation of a standard XY-based protocol may enhance the sensitivities only for measuring high-frequency fields, for which many ( > 500 ) DD pulses are necessary and the robustness against pulse imperfections is critical. Moreover, we show that cooling is effective only for measuring low-frequency fields (∼10 kHz), for which the experiment time approaches T 1 at a small number of applied DD pulses.

arXiv:1709.03368•Journal of Optics•Dec 14, 2017•15 citations
Ultimate sensitivity for quantum magnetometry using nitrogen-vacancy (NV) centers in a diamond is limited by a number of NV centers and coherence time. Microwave irradiation with a high and homogeneous power density for a large detection volume is necessary to achieve a highly sensitive magnetometer. Here, we demonstrate a microwave resonator to enhance the power density of the microwave field and an optical system with a detection volume of 1.4 × 10−3 mm3. The strong microwave field enables us to achieve 48 ns Rabi oscillation which is sufficiently faster than the phase relaxation time of NV centers. This system combined with a decoupling pulse sequence, XY16, extends the spin coherence time (T2) up to 27 times longer than that with a spin echo method. Consequently, we obtained an AC magnetic field sensitivity of 10.8 pt/Hz using the dynamical decoupling pulse sequence.
A single nitrogen-vacancy (NV) center in diamond is utilized to perform nanoscale magnetic measurements. However, the low contrast and poor collection efficiency of spin-dependent emitted photons limited the instrument sensitivity to approximately several nT/Hz. Here, we design a diamond magnetometer based on a chiral waveguide. We numerically demonstrate that the proposed device achieves a sensitivity of 170 pT/Hz owing to near-unity contrast and efficient photon collection. We also confirm that the device sensitivity is robust against position misalignment and dipole misorientation of an NV center. The proposed approach will enable the construction of a highly-sensitive magnetometer with high spatial resolution.
Abstract Ensembles of nitrogen-vacancy centers in diamond are widely used as AC magnetometers. While such measurements are usually performed using standard (XY) dynamical decoupling (DD) protocols at room temperature, we study the sensitivities achieved by utilizing various DD protocols, for measuring magnetic AC fields at frequencies in the 10–250 kHz range, at room temperature and 77 K. By performing measurements on an isotopically pure 12 C sample, we find that the Carr-Purcell–Meiboom-Gill protocol, which is not robust against pulse imperfections, is less efficient for magnetometry than robust XY-based sequences. The concatenation of a standard XY-based protocol may enhance the sensitivities only for measuring high-frequency fields, for which many ( > 500 ) DD pulses are necessary and the robustness against pulse imperfections is critical. Moreover, we show that cooling is effective only for measuring low-frequency fields (∼10 kHz), for which the experiment time approaches T 1 at a small number of applied DD pulses.