Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

精密測定への弱値増幅の応用可能性について

Yuichiro Mori

Published Mar 19, 2021• 0 citations
Publisher

Abstract

The novel notion of a physical quantity called 'weak value', which was proposed by Aharonov et al. in 1988, has attracted much attention in the fields of quantum foundations and quantum measurement.In particular, the fact that through proper state selections the weak value can be made arbitrarily large, exceeding the conventional bound set by the maximum eigenvalue of the physical observable, has been widely regarded as a promising source for precision measurement.Indeed, in recent years we have seen increasingly many reports of successful applications of the weak value in photonic systems with various instances of observables amplified effectively.However, it has also been recognized that there are two major obstacles in realizing this weak value amplification (WVA).First, it is unclear under what conditions the WVA becomes effective due to the conflict between the ambiguity caused by the state selections and the amplification effect.Second, the required state selections may not be available depending on the systems one is dealing with.In order to expand the applicability of the WVA, one must solve these problems properly.In this dissertation, we first review the basics of precision measurement and the WVA and then present our method of evaluation for the WVA considering the measurement uncertainty including the ambiguity of the WVA.We applied our method of evaluation for the two celebrated experiments to confirm the basic validity of the results of the two experiments.In addition, as a new application of the WVA, we consider the time evolution of unstable particles to find that the decay time distribution is generally characterized by the weak value of the Hamiltonian and that the state selections can indeed be performed by measuring the particles produced during the decay.Our result indicates that the WVA may also be applicable to the system of unstable particles.

DOI
10.15083/0002006672

Related papers

Weak-Values Metrological Techniques for Parameter Estimation

Julián Martínez-Rincón

Precision measurements are bounded by the Standard Quantum Limit, and prepar- ing non-classical states is often used to circumvent such a limit. In all cases, it is common to improve the precision in a parameter estimation procedure by averaging measurements of a large ensemble of identically prepared systems. However, such a task cannot be performed indefinitely due to sources of technical noise setting an experimental bound. Weak-Value Amplification (WVA) allows one to overcome some of these issues by amplifying a signal of interest above the technical-noise floor. This built-in robustness to external sources of noise relies on a weak coupling to a meter and postselection. In this document we evaluate, the- oretically and experimentally, under what circumstances the technique is superior to non-postselected standard techniques. We also present a novel protocol where a WVA-like response is induced in an optical homodyne-type detection technique. We dub this technique Almost-Balanced Weak Values (ABWV) and present three experimental measurements of different physical velocities to evaluate the practi- cal advantages over the well-known technique of WVA. In addition, we point out the existence of a third postselected-weak-measurements technique for metrology, Inverse Weak Value (IWV), that has been ignored by the scientific community. We use this protocol to measure ultra small tilts of a mirror in a Sagnac interfer- ometer. We report all three techniques as complementary to each other, and show their robustness for low-frequency signals.

•Jan 1, 2017•0 citations

On the validity of weak measurement applied for precision measurement

Yuichiro Mori, Jaeha Lee, Izumi Tsutsui

Abstract We present a general framework of examining the validity of weak measurement—the standard procedure to acquire Aharonov’s weak value—which has been used intensively in recent years for precision measurement, exploiting the amplification mechanism available for the weak value. Our framework allows one to deal systematically with various causes of uncertainties intrinsic to the actual measurement process as well as those found in the theoretical analysis employed to describe the system. Using our framework, we examine in detail the two seminal experiments, Hosten’s detection measurement of the spin Hall effect of light [Hosten and Kwiat 2008 Science 319 787] and Dixon’s ultra sensitive beam deflection measurement [Dixon et al 2009 Phys. Rev. Lett. 102 173601]. Our analysis shows that their results are well within the range of amplification (actually in the vicinity of the optimal point) where the weak measurements are valid. This suggests that our framework is both practical and sound, and may be useful to determine beforehand the possible extent of amplification in the future weak measurement experiments.

arXiv:1901.06831•Journal of Physics B Atomic Molecular and Optical Physics•Oct 28, 2019•10 citations

Weak Value Amplification of a Post-Selected Single Photon

Matin Hallaji

Weak value amplification (WVA) is a measurement technique in which the effect of a pre- and post-selected system on a weakly interacting probe is magnified. In this thesis, I present the first experimental observation of WVA of a single photon. We observed that a signal photon - sent through a polarization interferometer and post-selected by photodetection in the almost-dark port - can act like eight photons. The effect of this single photon is measured as a nonlinear phase shift on a separate laser beam. The interaction between the two is mediated by a sample of laser- cooled 85Rb atoms. Electromagnetically induced transparency (EIT) is used to enhance the nonlinearity and overcome resonant absorption. I believe this work to be the first demonstration of WVA where a deterministic interaction is used to entangle two distinct optical systems. In WVA, the amplification is contingent on discarding a large portion of the original data set. While amplification increases measurement sensitivity, discarding data worsens it. Questioning whether these competing effects conspire to improve or diminish measurement accuracy has resulted recently in controversy. I address this question by calculating the maximum amount of information achievable with the WVA technique. By comparing this information to that achievable by the standard technique, where no post-selection is employed, I show that the WVA technique can be advantageous under a certain class of noise models. Finally, I propose a way to optimally apply the WVA technique.

•Jun 1, 2016•1 citation

Roadmap on Weak Measurements in Optics

Ritwik Dhara, Niladri Modak, Shyamal Guchhait +1 more

Abstract Even though weak measurements and weak value amplification (WVA) are founded on the principles of quantum mechanics and quantum measurements, these have found widespread applications in optics due to their inherent origin in wave interference. Besides their use in addressing foundational questions of quantum mechanics or for resolving quantum paradoxes, weak measurements and WVA have thus been used for numerous metrological applications, e.g., quantification of small optical beam displacement, tiny angular rotation, determination of extremely small phase shifts, spectral shifts, unraveling weak fundamental optical effects, improved optical imaging, amplifying weak signal and extracting small physical parameters and so forth. In this review, after providing the mathematical foundation of weak measurement and WVA, some of the metrological applications of weak measurements in the classical optics domain are briefly summarized, and the controversies and debates on the potential advantages of WVA in the estimation and detection of weak signal are discussed, and the interferometric philosophy of WVA is elucidated. The experimental weak measurement and WVA schemes in the domain of quantum optics are also discussed and highlighted the new perspectives and emerging trends of weak measurements in both the classical and quantum optics domain and their prospects in the development of next‐generation ultra‐sensitive optical devices.

Advanced Physics Research•Dec 19, 2024•7 citations

Weak-value amplification and the lifetime of a decaying particle

Yuichiro Mori, Izumi Tsutsui

We study the possibility of varying the measured lifetime of a decaying particle based on the technique of weak value amplification in which an additional filtering process called postselection is performed. Our analysis made in a direct measurement scheme presented here shows that, for simple two-level systems, the lifetime may be prolonged more than three times compared to the original one, while it can also be shortened arbitrarily by a proper choice of postselection. This result is consistent with our previous analysis on the possible prolongation of the lifetime of $B$ mesons that may be observed in laboratories, and suggests room for novel applications of weak-value amplification beyond precision measurement conventionally considered.

arXiv:2105.12349•Physical Review A•Sep 1, 2021•3 citations

How the Result of Counting One Photon Can Turn Out to Be a Value of 8

Matin Hallaji, Amir Feizpour, Greg Dmochowski +2 more

In 1988, Aharonov, Albert, and Vaidman introduced a new paradigm of quantum measurement in a paper which had the unwieldy but provocative title "How the result of a measurement of a component of the spin of a spin-1=2 particle can turn out to be 100." This paradigm, so-called "weak measurement," has since been the subject of widespread theoretical and experimental attention, both for the perspective it offers on quantum reality and for possible applications to precision measurement. Yet almost all of the weak-measurement experiments carried out so far could be alternatively understood in terms of the classical (electro-magnetic wave) theory of optics. Here we present a truly quantum version, the first in which a measurement apparatus deterministically entangles two distinct optical beams, enabling us to experimentally ask a question directly analogous to that of the original proposal: "In a two-arm interferometer containing one photon in total, can the result of a measurement of the photon number in one arm turn out to be greater than 1?" Specifically, we show that a single photon, when properly post-selected, can have an effect equal to that of eight photons: that is, in a system where a single photon has been calibrated to write a nonlinear phase shift of ϕ_0 on a probe beam, we measure phase shifts as large as 8ϕ_0 for appropriately post-selected single photons. This is the first deterministic weak-value experiment in optics which defies classical explanation, and constitutes a realization of our proposal for weak-value amplification (WVA) of the small optical nonlinearity at the single-photon level. It opens up a new regime for the study of entanglement of optical beams, as well as further investigations of the power of WVA for the measurement of small quantities.

arXiv:1612.04920•Dec 15, 2016•2 citations
The novel notion of a physical quantity called 'weak value', which was proposed by Aharonov et al. in 1988, has attracted much attention in the fields of quantum foundations and quantum measurement.In particular, the fact that through proper state selections the weak value can be made arbitrarily large, exceeding the conventional bound set by the maximum eigenvalue of the physical observable, has been widely regarded as a promising source for precision measurement.Indeed, in recent years we have seen increasingly many reports of successful applications of the weak value in photonic systems with various instances of observables amplified effectively.However, it has also been recognized that there are two major obstacles in realizing this weak value amplification (WVA).First, it is unclear under what conditions the WVA becomes effective due to the conflict between the ambiguity caused by the state selections and the amplification effect.Second, the required state selections may not be available depending on the systems one is dealing with.In order to expand the applicability of the WVA, one must solve these problems properly.In this dissertation, we first review the basics of precision measurement and the WVA and then present our method of evaluation for the WVA considering the measurement uncertainty including the ambiguity of the WVA.We applied our method of evaluation for the two celebrated experiments to confirm the basic validity of the results of the two experiments.In addition, as a new application of the WVA, we consider the time evolution of unstable particles to find that the decay time distribution is generally characterized by the weak value of the Hamiltonian and that the state selections can indeed be performed by measuring the particles produced during the decay.Our result indicates that the WVA may also be applicable to the system of unstable particles.
Precision measurements are bounded by the Standard Quantum Limit, and prepar- ing non-classical states is often used to circumvent such a limit. In all cases, it is common to improve the precision in a parameter estimation procedure by averaging measurements of a large ensemble of identically prepared systems. However, such a task cannot be performed indefinitely due to sources of technical noise setting an experimental bound. Weak-Value Amplification (WVA) allows one to overcome some of these issues by amplifying a signal of interest above the technical-noise floor. This built-in robustness to external sources of noise relies on a weak coupling to a meter and postselection. In this document we evaluate, the- oretically and experimentally, under what circumstances the technique is superior to non-postselected standard techniques. We also present a novel protocol where a WVA-like response is induced in an optical homodyne-type detection technique. We dub this technique Almost-Balanced Weak Values (ABWV) and present three experimental measurements of different physical velocities to evaluate the practi- cal advantages over the well-known technique of WVA. In addition, we point out the existence of a third postselected-weak-measurements technique for metrology, Inverse Weak Value (IWV), that has been ignored by the scientific community. We use this protocol to measure ultra small tilts of a mirror in a Sagnac interfer- ometer. We report all three techniques as complementary to each other, and show their robustness for low-frequency signals.
Abstract We present a general framework of examining the validity of weak measurement—the standard procedure to acquire Aharonov’s weak value—which has been used intensively in recent years for precision measurement, exploiting the amplification mechanism available for the weak value. Our framework allows one to deal systematically with various causes of uncertainties intrinsic to the actual measurement process as well as those found in the theoretical analysis employed to describe the system. Using our framework, we examine in detail the two seminal experiments, Hosten’s detection measurement of the spin Hall effect of light [Hosten and Kwiat 2008 Science 319 787] and Dixon’s ultra sensitive beam deflection measurement [Dixon et al 2009 Phys. Rev. Lett. 102 173601]. Our analysis shows that their results are well within the range of amplification (actually in the vicinity of the optimal point) where the weak measurements are valid. This suggests that our framework is both practical and sound, and may be useful to determine beforehand the possible extent of amplification in the future weak measurement experiments.
Weak value amplification (WVA) is a measurement technique in which the effect of a pre- and post-selected system on a weakly interacting probe is magnified. In this thesis, I present the first experimental observation of WVA of a single photon. We observed that a signal photon - sent through a polarization interferometer and post-selected by photodetection in the almost-dark port - can act like eight photons. The effect of this single photon is measured as a nonlinear phase shift on a separate laser beam. The interaction between the two is mediated by a sample of laser- cooled 85Rb atoms. Electromagnetically induced transparency (EIT) is used to enhance the nonlinearity and overcome resonant absorption. I believe this work to be the first demonstration of WVA where a deterministic interaction is used to entangle two distinct optical systems. In WVA, the amplification is contingent on discarding a large portion of the original data set. While amplification increases measurement sensitivity, discarding data worsens it. Questioning whether these competing effects conspire to improve or diminish measurement accuracy has resulted recently in controversy. I address this question by calculating the maximum amount of information achievable with the WVA technique. By comparing this information to that achievable by the standard technique, where no post-selection is employed, I show that the WVA technique can be advantageous under a certain class of noise models. Finally, I propose a way to optimally apply the WVA technique.
Abstract Even though weak measurements and weak value amplification (WVA) are founded on the principles of quantum mechanics and quantum measurements, these have found widespread applications in optics due to their inherent origin in wave interference. Besides their use in addressing foundational questions of quantum mechanics or for resolving quantum paradoxes, weak measurements and WVA have thus been used for numerous metrological applications, e.g., quantification of small optical beam displacement, tiny angular rotation, determination of extremely small phase shifts, spectral shifts, unraveling weak fundamental optical effects, improved optical imaging, amplifying weak signal and extracting small physical parameters and so forth. In this review, after providing the mathematical foundation of weak measurement and WVA, some of the metrological applications of weak measurements in the classical optics domain are briefly summarized, and the controversies and debates on the potential advantages of WVA in the estimation and detection of weak signal are discussed, and the interferometric philosophy of WVA is elucidated. The experimental weak measurement and WVA schemes in the domain of quantum optics are also discussed and highlighted the new perspectives and emerging trends of weak measurements in both the classical and quantum optics domain and their prospects in the development of next‐generation ultra‐sensitive optical devices.
We study the possibility of varying the measured lifetime of a decaying particle based on the technique of weak value amplification in which an additional filtering process called postselection is performed. Our analysis made in a direct measurement scheme presented here shows that, for simple two-level systems, the lifetime may be prolonged more than three times compared to the original one, while it can also be shortened arbitrarily by a proper choice of postselection. This result is consistent with our previous analysis on the possible prolongation of the lifetime of BBB mesons that may be observed in laboratories, and suggests room for novel applications of weak-value amplification beyond precision measurement conventionally considered.
In 1988, Aharonov, Albert, and Vaidman introduced a new paradigm of quantum measurement in a paper which had the unwieldy but provocative title "How the result of a measurement of a component of the spin of a spin-1=2 particle can turn out to be 100." This paradigm, so-called "weak measurement," has since been the subject of widespread theoretical and experimental attention, both for the perspective it offers on quantum reality and for possible applications to precision measurement. Yet almost all of the weak-measurement experiments carried out so far could be alternatively understood in terms of the classical (electro-magnetic wave) theory of optics. Here we present a truly quantum version, the first in which a measurement apparatus deterministically entangles two distinct optical beams, enabling us to experimentally ask a question directly analogous to that of the original proposal: "In a two-arm interferometer containing one photon in total, can the result of a measurement of the photon number in one arm turn out to be greater than 1?" Specifically, we show that a single photon, when properly post-selected, can have an effect equal to that of eight photons: that is, in a system where a single photon has been calibrated to write a nonlinear phase shift of ϕ_0 on a probe beam, we measure phase shifts as large as 8ϕ_0 for appropriately post-selected single photons. This is the first deterministic weak-value experiment in optics which defies classical explanation, and constitutes a realization of our proposal for weak-value amplification (WVA) of the small optical nonlinearity at the single-photon level. It opens up a new regime for the study of entanglement of optical beams, as well as further investigations of the power of WVA for the measurement of small quantities.