Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Quantum Computing, Communication, and Simulation

Electron beam profiling via Rydberg electromagnetically induced transparency in rubidium vapor with crossed laser beams

Rob Behary, Kevin Su, Nicolas DeStefano, Jennifer Tsai, Todd Averett, A. Camsonne, Shukui Zhang, Charles Fancher, Neel Malvania, S. Aubin, Eugeniy E. Mikhailov, Irina V. Novikova

Published Mar 5, 2026• 0 citations
Publisher
DOI
10.1117/12.3087722

Related papers

Influence of spin-orbit coupling mode of vector vortex beam on the electromagnetically induced transparency and absorption in rubidium vapor

Samim Akhtar, Rakiba Rahaman, M. Jalaluddin +2 more

The European Physical Journal Plus•Sep 5, 2025•1 citation

Electron Beam Profiling via Rydberg Electromagnetically Induced Transparency in Rubidium Vapor with Crossed Laser beams

Rob Behary, Kevin Su, Nicolas DeStefano +9 more

We present an all-optical detection approach to determine the position and spatial profile of an electron beam based on quantum properties of alkali metal atoms. To measure the electric field, produced by an electron beam, we excite thermal rubidium atoms to a highly excited Rydberg state via a two-photon ladder transition and detect Stark shifts of Rydberg states by monitoring frequencies of the corresponding electromagnetically induced transparency (EIT) transmission peaks. We addressed several technical challenges in this approach. First, we use crossed laser beams to obtain spatial information about the electron beam position and geometry. Second, by pulsing the electron beam and using phase-sensitive optical detection, we separate the true electron beam electric signature from the parasitic electric fields due to photoelectric charges on the windows. Finally, we use a principle component analysis to further improve signal quality. We test this method to detect the current and to reconstruct a 2D profile of a 20 keV electron beam with currents ranging from 25 - 100 uA. While this technique provides less spatial resolution than fluorescence-based measurements, thanks to their speed and limited optical access requirements it can be useful for real-time non-invasive diagnostics of charged particle beams at accelerator facilities.

arXiv:2601.02549•Jan 5, 2026•1 citation

Electromagnetically induced transparency schemes within rubidium vapor

Sara Shepherd, David J. Fulton, Richard R. Moseley +2 more

Quantum Electronics and Laser Science Conference•May 22, 1995•0 citations

Spectroscopy of Potassium Rydberg States via Electromagnetically Induced Transparency

Wenchao Xu, Brian DeMarco

Bulletin of the American Physical Society•Jun 3, 2014•0 citations

Effects of laser beam diameter on electromagnetically induced transparency due to Zeeman coherences in Rb vapor

Stanko N. Nikolić, Aleksandar J. Krmpot, Nemanja Lučić +3 more

We experimentally studied the effects of laser beam diameter on electromagnetically induced transparency (EIT) due to Zeeman coherences induced by a laser resonant with the hyperfine transition Fg = 2 → Fe = 1 of 87Rb in a rubidium buffer gas cell. We use two laser beams of Gaussian intensity radial profile for laser beam diameters of 6.5 and 1.3 mm, laser intensities in the range of 0.1–35 mW cm−2 and cell temperatures between 60 and 82 °C. The results show that the amplitude of the normalized EIT resonance has a maximum at a laser intensity which depends on laser beam diameter and cell temperature. The laser intensity corresponding to the maximum EIT amplitude is higher for a smaller laser beam and higher cell temperature. The linewidth of Zeeman EIT resonance varies nearly linearly with laser intensity, almost independent of cell temperature and laser beam diameter.

Physica Scripta•Nov 1, 2013•6 citations

Investigation of Electromagnetically Induced Transparency in the Rubidium Vapor

Bahaa Toama Chiad, Abass H. Al-Wattar, Ahmed N. Abdullah

We have studied theoretically the response of atomic three- level cascade scheme of rubidium vapor to a strong laser under conditions in which electromagnetically induced transparency would be induced on a weak probe beam. We show that the medium that is an opaque to a probe laser can, by applying both lasers simultaneously, be made transparent.

Iraqi Journal of Physics•Mar 1, 2008•0 citations
We present an all-optical detection approach to determine the position and spatial profile of an electron beam based on quantum properties of alkali metal atoms. To measure the electric field, produced by an electron beam, we excite thermal rubidium atoms to a highly excited Rydberg state via a two-photon ladder transition and detect Stark shifts of Rydberg states by monitoring frequencies of the corresponding electromagnetically induced transparency (EIT) transmission peaks. We addressed several technical challenges in this approach. First, we use crossed laser beams to obtain spatial information about the electron beam position and geometry. Second, by pulsing the electron beam and using phase-sensitive optical detection, we separate the true electron beam electric signature from the parasitic electric fields due to photoelectric charges on the windows. Finally, we use a principle component analysis to further improve signal quality. We test this method to detect the current and to reconstruct a 2D profile of a 20 keV electron beam with currents ranging from 25 - 100 uA. While this technique provides less spatial resolution than fluorescence-based measurements, thanks to their speed and limited optical access requirements it can be useful for real-time non-invasive diagnostics of charged particle beams at accelerator facilities.
We experimentally studied the effects of laser beam diameter on electromagnetically induced transparency (EIT) due to Zeeman coherences induced by a laser resonant with the hyperfine transition Fg = 2 → Fe = 1 of 87Rb in a rubidium buffer gas cell. We use two laser beams of Gaussian intensity radial profile for laser beam diameters of 6.5 and 1.3 mm, laser intensities in the range of 0.1–35 mW cm−2 and cell temperatures between 60 and 82 °C. The results show that the amplitude of the normalized EIT resonance has a maximum at a laser intensity which depends on laser beam diameter and cell temperature. The laser intensity corresponding to the maximum EIT amplitude is higher for a smaller laser beam and higher cell temperature. The linewidth of Zeeman EIT resonance varies nearly linearly with laser intensity, almost independent of cell temperature and laser beam diameter.