Do Quantum Computers Require Quantum Impedance Matching?

Peter Cameron, Michigan / Mit, Brookhaven

Published Jan 1, 2026• 0 citations
Publisher
DOI
10.13140/rg.2.2.20533.95207

Related papers

Quantum Computation as Impedance Matching: Translating Free-Space Quantum Impedance Networks to Superconducting Circuits

Peter Cameron, Michigan / Mit, Brookhaven

•Jan 1, 2026•0 citations

Robust quantum state transfer without impedance matching

Mengzhen Zhang, Chang‐Ling Zou, Liang Jiang

Bulletin of the American Physical Society•Mar 14, 2017•0 citations

Sensitive Radio-Frequency Measurements of a Quantum Dot by Tuning to Perfect Impedance Matching

N. Ares, F. J. Schupp, A. Mavalankar +9 more

Electrical readout of spin qubits requires fast, sensitive measurements, which are hindered by poor impedance matching in a practical device. The authors demonstrate perfect impedance matching in an rf readout circuit, measure the absolute sensitivity to quantum capacitance changes, and establish a clear requirement for single-shot readout. This work will aid research not just in quantum computing, but also in nanomechanics and ac quantum transport.

arXiv:1510.06944•Physical Review Applied•Mar 24, 2016•69 citations

Near-unity charge readout signal in a nonlinear resonator without matching the sensor dissipation

Harald Havir, Andrea Cicovic, P. Glidic +4 more

Dissipative sensors typically use linear resonators with impedance matching to achieve maximal signal and fast operation. The impedance matching, however, sets an upper limit to the bandwidth of the readout. In this paper, we present a nonlinear resonator performing the readout of a double quantum dot charge state via a charge-sensing quantum dot. We show that by driving the resonator in the nonlinear regime, we achieve a near-unity signal for a dissipative sensor. This despite not satisfying the sensor impedance matching requirements necessary for such large signals in the linear regime. Our experiments, supported by numerical calculations, demonstrate that the signal increase stems from the sensor dissipation shifting the onset of the nonlinear resonator response. By lifting the matching requirement, we open up an avenue to ultra-fast charge detectors as the resonator input-output coupling - setting the detector bandwidth - does not have to match to the typically much slower sensor dissipation rate.

arXiv:2505.17709•Nature Communications•Jul 2, 2026•5 citations

How do we verify and validate a quantum computer

Sarah Sheldon, David C. McKay, Jerry M. Chow +1 more

Bulletin of the American Physical Society•Mar 9, 2018•0 citations

Active impedance matching of a cryogenic radio frequency resonator for ion traps

M. Schubert, L. Kilzer, T. Dubielzig +3 more

A combination of direct current (DC) fields and high amplitude radio frequency (RF) fields is necessary to trap ions in a Paul trap. Such high electric RF fields are usually reached with the help of a resonator in close proximity to the ion trap. Ion trap based quantum computers profit from good vacuum conditions and low heating rates that cryogenic environments provide. However, an impedance matching network between the resonator and its RF source is necessary, as an unmatched resonator would require higher input power due to power reflection. The reflected power would not contribute to the RF trapping potential, and the losses in the cable induce additional heat into the system. The electrical properties of the matching network components change during cooling, and a cryogenic setup usually prohibits physical access to integrated components while the experiment is running. This circumstance leads to either several cooling cycles to improve the matching at cryogenic temperatures or the operation of poorly matched resonators. In this work, we demonstrate an RF resonator that is actively matched to the wave impedance of coaxial cables and the signal source. The active part of the matching circuit consists of a varactor diode array. Its capacitance depends on the DC voltage applied from outside the cryostat. We present measurements of the power reflection, the Q-factor, and higher harmonic signals resulting from the nonlinearity of the varactor diodes. The RF resonator is tested in a cryostat at room temperature and cryogenic temperatures, down to 4.3 K. A superior impedance matching for different ion traps can be achieved with this type of resonator.

Review of Scientific Instruments•Sep 1, 2022•3 citations
Dissipative sensors typically use linear resonators with impedance matching to achieve maximal signal and fast operation. The impedance matching, however, sets an upper limit to the bandwidth of the readout. In this paper, we present a nonlinear resonator performing the readout of a double quantum dot charge state via a charge-sensing quantum dot. We show that by driving the resonator in the nonlinear regime, we achieve a near-unity signal for a dissipative sensor. This despite not satisfying the sensor impedance matching requirements necessary for such large signals in the linear regime. Our experiments, supported by numerical calculations, demonstrate that the signal increase stems from the sensor dissipation shifting the onset of the nonlinear resonator response. By lifting the matching requirement, we open up an avenue to ultra-fast charge detectors as the resonator input-output coupling - setting the detector bandwidth - does not have to match to the typically much slower sensor dissipation rate.
A combination of direct current (DC) fields and high amplitude radio frequency (RF) fields is necessary to trap ions in a Paul trap. Such high electric RF fields are usually reached with the help of a resonator in close proximity to the ion trap. Ion trap based quantum computers profit from good vacuum conditions and low heating rates that cryogenic environments provide. However, an impedance matching network between the resonator and its RF source is necessary, as an unmatched resonator would require higher input power due to power reflection. The reflected power would not contribute to the RF trapping potential, and the losses in the cable induce additional heat into the system. The electrical properties of the matching network components change during cooling, and a cryogenic setup usually prohibits physical access to integrated components while the experiment is running. This circumstance leads to either several cooling cycles to improve the matching at cryogenic temperatures or the operation of poorly matched resonators. In this work, we demonstrate an RF resonator that is actively matched to the wave impedance of coaxial cables and the signal source. The active part of the matching circuit consists of a varactor diode array. Its capacitance depends on the DC voltage applied from outside the cryostat. We present measurements of the power reflection, the Q-factor, and higher harmonic signals resulting from the nonlinearity of the varactor diodes. The RF resonator is tested in a cryostat at room temperature and cryogenic temperatures, down to 4.3 K. A superior impedance matching for different ion traps can be achieved with this type of resonator.