Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

ION TRAP SYSTEM TOWARDS 176LU+ 3D2 CLOCK TRANSITION

ZHAO QI

Published Jul 29, 2025• 0 citations
OpenAlex

Related papers

ADVANCES IN ATOMIC CLOCK AND ION TRAP RESEARCHES

朱熙文

Progress in Natural Science Materials International•Jan 1, 1991•0 citations

ABSOLUTE FREQUENCY MEASUREMENT OF THE 40 Ca + 4s 2S1/2 - 3d 2D5/2 CLOCK TRANSITION

Michael Chwalla, Jan Benhelm, K. Kim +12 more

We report on an absolute frequency measurement with a single 40 Ca + ion in a linear Paul trap. A frequency comb referenced to the transportable Cs atomic fountain clock of LNE-SYRTE is used to measure the frequency of a laser exciting the 40 Ca + 4s 2 S 1/2 - 3d 2 D 5/2 electric-quadrupole transition. A transition frequency of ν Ca + = 411 042 129 776 393.2(1.0) Hz was obtained, which corresponds to a fractional uncertainty of 2.4 × 10 -15 .

Symposium on Frequency Standards and Metrology•May 1, 2009•24 citations

Trapped Ion Optical Clocks

Patrick Robert Gill

Bulletin of the American Physical Society•Mar 14, 2006•1 citation

A Multi-Frequency Approach to the Definition of a Frequency Standard Using 176Lu+

K. J. Arnold, R. Kaewuam, Ting Rei Tan +1 more

A definition of a frequency standard that utilizes multiple clock transitions within a single atom is considered. Under experimentally achievable conditions, it is shown that the operating conditions of the system can be constrained by the definition of all available clock frequencies. Systems calibrated to the standard would then provide identical levels of performance, with the exclusion of relativistic effects as these do not influence frequency ratios. This would provide a globally certifiable optical frequency reference. An implementation using three clock transitions in176Lu+is considered.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 1, 2019•0 citations

Trapped Ion Spectroscopy

Frank Schlawin

Springer theses•Sep 10, 2016•3 citations

Lu+ optical frequency references with accuracy verified at the 19th digit

K. J. Arnold, Michael Dao Kang Lee, Qi Zhao +4 more

Optical atomic frequency references1 have far surpassed their microwave frequency predecessors, leading to an anticipated redefinition of the SI (International System of Units) second2. However, as the scientific community seeks consensus on a new standard, and several state-of-the-art optical standards now report evaluated fractional uncertainties below 10−18, verification by same-species comparisons to comparable levels remains an outstanding challenge. Here we report two 176Lu+ single-ion optical frequency references, each with evaluated fractional frequency uncertainty near 1 × 10−19, which are directly compared by correlation spectroscopy and demonstrate agreement, with a measured relative frequency difference of [−0.1 ± (5.7)stat ± (1.0)sys] × 10−19, where ‘stat’ and ‘sys’ indicate the statistical and systematic uncertainty, respectively. Our optical references have been comprehensively assessed with evaluated uncertainties below 10−18, supported by a same-species comparison of independent systems to the 5.7 × 10−19 level. This accuracy, achieved in practical room-temperature systems, will contribute to improving international timekeeping and towards chronometric levelling3,4 at the millimetre scale, as well as tests of fundamental physics5 such as Lorentz invariance6, general relativity7, searches for dark matter8,9 and variation of fundamental constants10,11. Two independent 176Lu+ single-ion optical clocks achieve fractional frequency uncertainties near 10−19 and agree at 5.7 × 10−19, advancing precision timekeeping.

arXiv:2512.07346•Nature•Sep 23, 2026•8 citations
A definition of a frequency standard that utilizes multiple clock transitions within a single atom is considered. Under experimentally achievable conditions, it is shown that the operating conditions of the system can be constrained by the definition of all available clock frequencies. Systems calibrated to the standard would then provide identical levels of performance, with the exclusion of relativistic effects as these do not influence frequency ratios. This would provide a globally certifiable optical frequency reference. An implementation using three clock transitions in176Lu+is considered.
Optical atomic frequency references1 have far surpassed their microwave frequency predecessors, leading to an anticipated redefinition of the SI (International System of Units) second2. However, as the scientific community seeks consensus on a new standard, and several state-of-the-art optical standards now report evaluated fractional uncertainties below 10−18, verification by same-species comparisons to comparable levels remains an outstanding challenge. Here we report two 176Lu+ single-ion optical frequency references, each with evaluated fractional frequency uncertainty near 1 × 10−19, which are directly compared by correlation spectroscopy and demonstrate agreement, with a measured relative frequency difference of [−0.1 ± (5.7)stat ± (1.0)sys] × 10−19, where ‘stat’ and ‘sys’ indicate the statistical and systematic uncertainty, respectively. Our optical references have been comprehensively assessed with evaluated uncertainties below 10−18, supported by a same-species comparison of independent systems to the 5.7 × 10−19 level. This accuracy, achieved in practical room-temperature systems, will contribute to improving international timekeeping and towards chronometric levelling3,4 at the millimetre scale, as well as tests of fundamental physics5 such as Lorentz invariance6, general relativity7, searches for dark matter8,9 and variation of fundamental constants10,11. Two independent 176Lu+ single-ion optical clocks achieve fractional frequency uncertainties near 10−19 and agree at 5.7 × 10−19, advancing precision timekeeping.