© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Symposium on Frequency Standards and Metrology

ABSOLUTE FREQUENCY MEASUREMENT OF THE 40 Ca + 4s 2S1/2 - 3d 2D5/2 CLOCK TRANSITION

Michael Chwalla, Jan Benhelm, K. Kim, Gerhard Kirchmair, Thomas Monz, Mark Riebe, Philipp Schindler, Alessandro S. Villar, W. Hänsel, Christian F. Roos, R. Blatt, Michel Abgrall, Giorgio Santarelli, Daniele Rovera, Philippe Laurent

Published May 1, 2009• 24 citations
Publisher

Abstract

We report on an absolute frequency measurement with a single 40 Ca + ion in a linear Paul trap. A frequency comb referenced to the transportable Cs atomic fountain clock of LNE-SYRTE is used to measure the frequency of a laser exciting the 40 Ca + 4s 2 S 1/2 - 3d 2 D 5/2 electric-quadrupole transition. A transition frequency of ν Ca + = 411 042 129 776 393.2(1.0) Hz was obtained, which corresponds to a fractional uncertainty of 2.4 × 10 -15 .

DOI
10.1142/9789812838223_0010

Related papers

Hertz-level measurement of the 40 Ca + 4s 2S1/2 – 3d 2D5/2 clock transition frequency with respect to the SI second through the Global Positioning System

Yao Huang, Jian Zhong Cao, P. Liu +6 more

We have measured the absolute frequency of a clock transition at the 10${}^{\ensuremath{-}15}$ level with a single, trapped, laser-cooled ${}^{40}$Ca${}^{+}$ ion in a miniature Paul trap. In our measurement, an optical frequency comb is referenced to a hydrogen maser, which is calibrated to the SI second through the Global Positioning System (GPS). By analyzing the experimental data obtained within 32 days of a total averaging time $>$2 $\ifmmode\times\else\texttimes\fi{}$ 10${}^{6}$ s, the absolute frequency of the ${}^{40}$Ca${}^{+}$ 4$s$ ${}^{2}\phantom{\rule{-0.16em}{0ex}}{S}_{1/2}$--3$d$ ${}^{2}\phantom{\rule{-0.16em}{0ex}}{D}_{5/2}$ clock transition is measured as 411 042 129 776 393.0 (1.6) Hz with a fractional uncertainty of 3.9 $\ifmmode\times\else\texttimes\fi{}$ 10${}^{\ensuremath{-}15}$.

arXiv:1111.5174•Physical Review A•Mar 23, 2012•61 citations

Frequency Measurement of the Electric Quadrupole Transition in a Single Laser-Cooled 40 Ca +

Qu Liu, Yao Huang, Jian Zhong Cao +5 more

The optical frequency of the 4s 2 S 1/2 -3d 2 D 5/2 transition in a single trapped and laser-cooled 40 Ca + ion is measured with an optical frequency comb system referenced to a hydrogen maser. A 729-nm laser can be locked to the clock transition about ten hours and the Allan deviation is better than 2 × 10 −14 /1000 s.

Chinese Physics Letters•Jan 1, 2011•13 citations

Optical frequency standard based on a single 40Ca+

Kelin Gao

Research on the development of the optical frequency standard based on trapped and cold 40 Ca + with the 4s 2 S 1/2 -3d 2 D 5/2 clock transition at 729 nm is reported. A single calcium ion was trapped and laser cooled in the Paul trap and stay in trap for more than 15 days. The linewidth of a 729 nm laser was reduced to less than 10 Hz by locking to a cavity for longer than 50 hours uninterruptedly. The overall systematic uncertainty of the clock transition has been characterized to be better than 6.5×10 −16 . The absolute frequency of the clock transition was measured at 10 −15 level using an optical frequency comb referenced to a Hydrogen maser, which was calibrated to the SI second through the global positioning system (GPS). The frequency value was 411042129776393.0(1.6) Hz after the correction of the systematic shifts.

Chinese Science Bulletin•Mar 1, 2013•9 citations

Frequency measurement of the40Ca+clock transition using a LD-based clock laser and UTC(NICT)

K. Matsubara, Y. Li, Shigeo Nagano +6 more

We developed an optical frequency standard with the 4 2S1/2-3 2D5/2 electric quadrupole transition of 40Ca+ ions. Its absolute transition frequency is 411 042 129 776 390(±7) Hz. The accuracy is limited by the electric quadrupole shift and the ambient magnetic field fluctuation. To determine the absolute transition frequency with a better accuracy, we have observed two pairs of the symmetrically-splitting Zeeman components and measured the transition frequency corrected for the electric quadrupole shift. In addition, we are developing a magnetic-shielded ion-trap chamber to suppress the transition-line broadening caused by the magnetic field fluctuation.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Aug 20, 2009•0 citations

SPECTROSCOPY AND PRECISION FREQUENCY MEASUREMENT OF THE 435.5 nm CLOCK TRANSITION OF 171 Yb +

Chr. Tamm, T. Schneider, E. Peik

We describe experimental investigations on an optical frequency standard based on a single laser cooled 171 Yb + ion confined in a radiofrequency Paul trap. The electric-quadrupole transition from the 2 S 1/2 ( F = 0) ground state to the 2 D 3/2 ( F = 2) state is used as the reference transition. Its wavelength is 435.5 nm and its natural linewidth is 3.1 Hz. The transition is probed using a diode laser system whose short-term frequency stability is derived from an environmentally isolated ULE cavity. The transition is resolved with a Fourier-limited full halfwidth of approximately 30 Hz. The absolute optical transition frequency was determined using a femtosecond frequency comb generator and a Cs fountain clock as the frequency reference. The measured frequency value is 688 358 979 309 312 Hz at an ambient blackbody radiation field of 300 K. The 1σ fractional uncertainty of this frequency measurement is 1 · 10 -14 .

Symposium on Frequency Standards and Metrology•May 1, 2002•3 citations

Hertz-Level Measurement of the Optical Clock Frequency in a Single 88 Sr + Ion

Helen S. Margolis, G. P. Barwood, Guozheng Huang +4 more

The frequency of the 5s 2S(1/2)-4d 2D(5/2) electric quadrupole clock transition in a single, trapped, laser-cooled 88Sr+ ion has been measured by using an optical frequency comb referenced to a cesium fountain primary frequency standard. The frequency of the transition is measured as 444,779,044,095,484.6 (1.5) hertz, with a fractional uncertainty within a factor of 3 of that of the cesium standard. Improvements required to obtain a cesium-limited frequency measurement are described and are expected to lead to a 88Sr+ optical clock with stability and reproducibility exceeding that of the primary cesium standard.

Science•Nov 18, 2004•301 citations
We report on an absolute frequency measurement with a single 40 Ca + ion in a linear Paul trap. A frequency comb referenced to the transportable Cs atomic fountain clock of LNE-SYRTE is used to measure the frequency of a laser exciting the 40 Ca + 4s 2 S 1/2 - 3d 2 D 5/2 electric-quadrupole transition. A transition frequency of ν Ca + = 411 042 129 776 393.2(1.0) Hz was obtained, which corresponds to a fractional uncertainty of 2.4 × 10 -15 .
We have measured the absolute frequency of a clock transition at the 10${}^{\ensuremath{-}15}$ level with a single, trapped, laser-cooled 40{}^{40}40Ca+{}^{+}+ ion in a miniature Paul trap. In our measurement, an optical frequency comb is referenced to a hydrogen maser, which is calibrated to the SI second through the Global Positioning System (GPS). By analyzing the experimental data obtained within 32 days of a total averaging time $>$2 $\ifmmode\times\else\texttimes\fi{}$ 106{}^{6}6 s, the absolute frequency of the 40{}^{40}40Ca+{}^{+}+ 4sss 2S1/2{}^{2}\phantom{\rule{-0.16em}{0ex}}{S}_{1/2}2S1/2​--3ddd 2D5/2{}^{2}\phantom{\rule{-0.16em}{0ex}}{D}_{5/2}2D5/2​ clock transition is measured as 411 042 129 776 393.0 (1.6) Hz with a fractional uncertainty of 3.9 $\ifmmode\times\else\texttimes\fi{}$ 10${}^{\ensuremath{-}15}$.
Research on the development of the optical frequency standard based on trapped and cold 40 Ca + with the 4s 2 S 1/2 -3d 2 D 5/2 clock transition at 729 nm is reported. A single calcium ion was trapped and laser cooled in the Paul trap and stay in trap for more than 15 days. The linewidth of a 729 nm laser was reduced to less than 10 Hz by locking to a cavity for longer than 50 hours uninterruptedly. The overall systematic uncertainty of the clock transition has been characterized to be better than 6.5×10 −16 . The absolute frequency of the clock transition was measured at 10 −15 level using an optical frequency comb referenced to a Hydrogen maser, which was calibrated to the SI second through the global positioning system (GPS). The frequency value was 411042129776393.0(1.6) Hz after the correction of the systematic shifts.
We developed an optical frequency standard with the 4 2S1/2-3 2D5/2 electric quadrupole transition of 40Ca+ ions. Its absolute transition frequency is 411 042 129 776 390(±7) Hz. The accuracy is limited by the electric quadrupole shift and the ambient magnetic field fluctuation. To determine the absolute transition frequency with a better accuracy, we have observed two pairs of the symmetrically-splitting Zeeman components and measured the transition frequency corrected for the electric quadrupole shift. In addition, we are developing a magnetic-shielded ion-trap chamber to suppress the transition-line broadening caused by the magnetic field fluctuation.
We describe experimental investigations on an optical frequency standard based on a single laser cooled 171 Yb + ion confined in a radiofrequency Paul trap. The electric-quadrupole transition from the 2 S 1/2 ( F = 0) ground state to the 2 D 3/2 ( F = 2) state is used as the reference transition. Its wavelength is 435.5 nm and its natural linewidth is 3.1 Hz. The transition is probed using a diode laser system whose short-term frequency stability is derived from an environmentally isolated ULE cavity. The transition is resolved with a Fourier-limited full halfwidth of approximately 30 Hz. The absolute optical transition frequency was determined using a femtosecond frequency comb generator and a Cs fountain clock as the frequency reference. The measured frequency value is 688 358 979 309 312 Hz at an ambient blackbody radiation field of 300 K. The 1σ fractional uncertainty of this frequency measurement is 1 · 10 -14 .
The frequency of the 5s 2S(1/2)-4d 2D(5/2) electric quadrupole clock transition in a single, trapped, laser-cooled 88Sr+ ion has been measured by using an optical frequency comb referenced to a cesium fountain primary frequency standard. The frequency of the transition is measured as 444,779,044,095,484.6 (1.5) hertz, with a fractional uncertainty within a factor of 3 of that of the cesium standard. Improvements required to obtain a cesium-limited frequency measurement are described and are expected to lead to a 88Sr+ optical clock with stability and reproducibility exceeding that of the primary cesium standard.