Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

On-Wafer Penetration Depth Measurements of Superconducting Films

Michael E. Cyberey, Robert M. Weikle, Arthur W. Lichtenberger

Published Mar 1, 2010• 1 citation
OpenAlex

Abstract

An on-wafer measurement technique allowing measurement of a superconducting film's penetration depth without post device-fabrication separation of the chips has been investigated. Coplanar waveguide (CPW) probes and a CPW to microstrip transition are utilized, allowing the use of commercially available LakeShore® CPX-1.5K cryogenic CPW probing station capable of microwave measurements to 50 GHz. The use of CPW probes allows for rapid prototyping and is nondestructive to the device wafers, and hence compatible with many device fabrication technologies. Measurement techniques utilizing resonant microwave circuits have been reported (1),(2), but require mounting to custom-made test fixtures and are not performed on-wafer, but instead on individual diced devices. However, such a dicing requirement is incompatible with our ultra-thin Si, Au beam-lead chip architecture (3). In addition to a traditional resonant circuit measurement technique, a technique that uses on-wafer calibration standards is discussed. The on-wafer calibration eliminates possible effects introduced by the testing setup and potentially offers additional advantages such as a size reduction and a direct measurement of RF loss. The designs and results for both measurement techniques are reported for NbTiN films.

Related papers

Interlaboratory Study of Cryogenic On-Wafer S-Parameter Measurements of CPW Microwave Devices

Lewis Manning, Daniel Stokes, Andrin Bagus +7 more

Cryogenic microwave on-wafer measurements underpin the development and validation of planar circuits used in quantum computing systems. This paper reports an interlaboratory comparison of cryogenic on-wafer S-parameter measurements performed on three coplanar waveguide (CPW) devices: a transmission line, a Beatty line, and a weakly coupled resonator. Measurements were carried out by three laboratories of the same devices on the same wafer over the frequency range 100 MHz to 14 GHz at indicated chuck temperatures below 6 K. The measured results and corresponding standard deviations are compared and discussed. The study provides useful insights into the reproducibility of cryogenic on-wafer S-parameter measurements and may serve as a reference for other laboratories developing similar capabilities.

European Microwave Conference (EuMC)•Oct 1, 2026•0 citations

Absolute measurement of penetration depth of superconducting thin films using microwave stripline resonators

Arghya Dutta, Ajeet Salunke, Mahesh Poojary +3 more

Superconducting microstrip resonators, which leverage kinetic inductance to probe electrodynamics, are sensitive tools for studying superconducting thin films at microwave frequencies. However, extracting the absolute superconducting penetration depth from these measurements remains challenging. In this work, we present a hybrid method to determine the absolute value of penetration depth over a wide temperature range by combining resonator measurements with finite-element electromagnetic simulations in COMSOL Multiphysics. We demonstrate this approach by extracting the penetration depth of NbN films by fabricating resonators from films of various thicknesses. Furthermore, we extend the technique to materials with lower critical temperatures by employing a flip-film geometry. By placing a sample above a NbN resonator, separated by a thin Mylar dielectric, we create a coupled structure where changes in the sample's penetration depth shift the resonant frequency. This non-destructive method provides a reliable, high-sensitivity platform for characterizing the penetration depth of diverse superconducting thin films.

arXiv:2605.28759•May 27, 2026•0 citations

Broadband RF Characterization and Modeling of Superconducting Coplanar Waveguides

Corentin Beilvert, Norman Vivien, Candice Thomas +4 more

We present the RF characterization of 2-µm-wide superconducting coplanar waveguides made of 100-nm-thick niobium (Nb) or niobium nitride (NbN) films fabricated on 200 mm silicon wafers. Measurements of the two-ports S-parameters up to 25 GHz in a 4.7K–14 K temperature range with an added direct current up to 115 mA were done using a cryogenic probe station. With proper RF calibration and de-embedding procedure, both temperature and dc current dependence of the RF superconducting properties are analyzed. We report a kinetic inductance of 0.15 pH/$\square$, a critical current density of 50 MA/cm$^{2}$, and a critical temperature of 8.9 K for Nb as well as 4.27 pH/$\square$, 3 MA/cm$^{2}$, and 13.8 K for NbN. A telegraphist transmission line model taking into account the BCS theory has been developed and the comparison with the measurements is discussed.

IEEE Transactions on Applied Superconductivity•Dec 13, 2024•0 citations

Broadband four-channel cryogenic wafer probing system for automated coplanar on-chip measurements

G. J. Höfer, F. Jäger, H. A. Kratz

An automated measurement system for cryogenic wafer probing is described. The system has been designed for up to four simultaneous broadband on-chip measurements in the temperature range from 4 to 300 K. Special requirements for superconducting samples have been taken into consideration. Most of the measurements needed for characterization of superconducting thin films and circuits can be done with a high degree of precision in the low- and high-frequency region. Details of the design are presented and the system performance is discussed.

Review of Scientific Instruments•Mar 1, 1993•3 citations

Cryogenic On-Chip In Situ S -Parameter Calibration Using Superconducting Coplanar Waveguides

Jeremy N. Thomas, Johannes Paul Hoffmann, Nathan E. Flowers-Jacobs +5 more

This article presents a new multiimpedance-state line (MISL) in situ scattering parameter (S-parameter) calibration technique using on-chip superconducting transmission lines at 4 K that enables cryogenic calibration in a fixed signal path without the need for cryogenic switches or a cryogenic probe station. The method uses coplanar waveguide (CPW) models based on various impedance states of niobium (Nb), which has zero dc resistance below 9 K and a monotonically increasing resistance from 10 K to room temperature. The different impedance states are accessed by heating the 4 K stage of a cryostat and injecting up to 245 mA of current into the line. Using these states, we solve for the unknowns in an eight-term error model through a least-squares analysis. We first validate the MISL calibration technique by comparing it with short-open-load-reciprocal (SOLR) calibrated measurements in a cryogenic probe station, finding transmission agreement within 0.2 dB and uncertainty overlap for nearly all frequencies up to 26.5 GHz. We then apply the method to calibrate Nb CPWs with and without embedded Josephson junctions (JJs), using a fixed wire bonded connection, and without the use of cryogenic switches or movable probes. Strong agreement with the CPW models is demonstrated, with uncertainty overlap and differences below 0.1 dB up to 4.6 GHz without JJs and up to 2.4 GHz with JJs; resonances cause interruptions beyond these frequencies.

IEEE Transactions on Microwave Theory and Techniques•Jul 16, 2025•2 citations

Effects of the thin-film thickness on superconducting NbTi microwave resonators for on-chip cryogenic thermometry

André Chatel, Roberto Russo, Luca Mazzone +5 more

Abstract Superconducting microwave resonators have recently gained a primary importance in the development of cryogenic applications, such as circuit quantum electrodynamics, electron spin resonance spectroscopy and particles detection for high-energy physics and astrophysics. In this work, we investigate the influence of the film thickness on the temperature response of microfabricated Nb 50 Ti 50 superconducting resonators. S-shaped split ring resonators (S-SRRs), approximately 20 nm to 150 nm thick, are designed to be electromagnetically coupled with standard Cu coplanar waveguides (CPWs) and their microwave properties are characterised at temperatures below 10 K . The combined contributions of the kinetic inductance L K ( T ) increase and the decreasing loaded quality factor Q L , for thinner films, induce an optimum condition on the temperature sensitivity and resolution of the resonators. A noise equivalent temperature as low as ( 0.53 ± 0.09 ) μ K Hz − 1 / 2 , at 1 Hz , is reported for 100 nm thick resonators at 4.2 K . We also asses the possibility of implementing a multiplexed frequency readout, allowing for the simultaneous temperature tracking of several sensors along a single CPW. Such results demonstrate the possibility to perform a distributed cryogenic temperature monitoring, with a sub- μ K resolution. Thus, the application of superconducting S-SRRs, eventually benefiting from an even higher

arXiv:2503.20416•Superconductor Science and Technology•Dec 1, 2025•1 citation
An on-wafer measurement technique allowing measurement of a superconducting film's penetration depth without post device-fabrication separation of the chips has been investigated. Coplanar waveguide (CPW) probes and a CPW to microstrip transition are utilized, allowing the use of commercially available LakeShore® CPX-1.5K cryogenic CPW probing station capable of microwave measurements to 50 GHz. The use of CPW probes allows for rapid prototyping and is nondestructive to the device wafers, and hence compatible with many device fabrication technologies. Measurement techniques utilizing resonant microwave circuits have been reported (1),(2), but require mounting to custom-made test fixtures and are not performed on-wafer, but instead on individual diced devices. However, such a dicing requirement is incompatible with our ultra-thin Si, Au beam-lead chip architecture (3). In addition to a traditional resonant circuit measurement technique, a technique that uses on-wafer calibration standards is discussed. The on-wafer calibration eliminates possible effects introduced by the testing setup and potentially offers additional advantages such as a size reduction and a direct measurement of RF loss. The designs and results for both measurement techniques are reported for NbTiN films.
Cryogenic microwave on-wafer measurements underpin the development and validation of planar circuits used in quantum computing systems. This paper reports an interlaboratory comparison of cryogenic on-wafer S-parameter measurements performed on three coplanar waveguide (CPW) devices: a transmission line, a Beatty line, and a weakly coupled resonator. Measurements were carried out by three laboratories of the same devices on the same wafer over the frequency range 100 MHz to 14 GHz at indicated chuck temperatures below 6 K. The measured results and corresponding standard deviations are compared and discussed. The study provides useful insights into the reproducibility of cryogenic on-wafer S-parameter measurements and may serve as a reference for other laboratories developing similar capabilities.
Superconducting microstrip resonators, which leverage kinetic inductance to probe electrodynamics, are sensitive tools for studying superconducting thin films at microwave frequencies. However, extracting the absolute superconducting penetration depth from these measurements remains challenging. In this work, we present a hybrid method to determine the absolute value of penetration depth over a wide temperature range by combining resonator measurements with finite-element electromagnetic simulations in COMSOL Multiphysics. We demonstrate this approach by extracting the penetration depth of NbN films by fabricating resonators from films of various thicknesses. Furthermore, we extend the technique to materials with lower critical temperatures by employing a flip-film geometry. By placing a sample above a NbN resonator, separated by a thin Mylar dielectric, we create a coupled structure where changes in the sample's penetration depth shift the resonant frequency. This non-destructive method provides a reliable, high-sensitivity platform for characterizing the penetration depth of diverse superconducting thin films.
We present the RF characterization of 2-µm-wide superconducting coplanar waveguides made of 100-nm-thick niobium (Nb) or niobium nitride (NbN) films fabricated on 200 mm silicon wafers. Measurements of the two-ports S-parameters up to 25 GHz in a 4.7K–14 K temperature range with an added direct current up to 115 mA were done using a cryogenic probe station. With proper RF calibration and de-embedding procedure, both temperature and dc current dependence of the RF superconducting properties are analyzed. We report a kinetic inductance of 0.15 pH/□\square□, a critical current density of 50 MA/cm2^{2}2, and a critical temperature of 8.9 K for Nb as well as 4.27 pH/□\square□, 3 MA/cm2^{2}2, and 13.8 K for NbN. A telegraphist transmission line model taking into account the BCS theory has been developed and the comparison with the measurements is discussed.
An automated measurement system for cryogenic wafer probing is described. The system has been designed for up to four simultaneous broadband on-chip measurements in the temperature range from 4 to 300 K. Special requirements for superconducting samples have been taken into consideration. Most of the measurements needed for characterization of superconducting thin films and circuits can be done with a high degree of precision in the low- and high-frequency region. Details of the design are presented and the system performance is discussed.
This article presents a new multiimpedance-state line (MISL) in situ scattering parameter (S-parameter) calibration technique using on-chip superconducting transmission lines at 4 K that enables cryogenic calibration in a fixed signal path without the need for cryogenic switches or a cryogenic probe station. The method uses coplanar waveguide (CPW) models based on various impedance states of niobium (Nb), which has zero dc resistance below 9 K and a monotonically increasing resistance from 10 K to room temperature. The different impedance states are accessed by heating the 4 K stage of a cryostat and injecting up to 245 mA of current into the line. Using these states, we solve for the unknowns in an eight-term error model through a least-squares analysis. We first validate the MISL calibration technique by comparing it with short-open-load-reciprocal (SOLR) calibrated measurements in a cryogenic probe station, finding transmission agreement within 0.2 dB and uncertainty overlap for nearly all frequencies up to 26.5 GHz. We then apply the method to calibrate Nb CPWs with and without embedded Josephson junctions (JJs), using a fixed wire bonded connection, and without the use of cryogenic switches or movable probes. Strong agreement with the CPW models is demonstrated, with uncertainty overlap and differences below 0.1 dB up to 4.6 GHz without JJs and up to 2.4 GHz with JJs; resonances cause interruptions beyond these frequencies.
Abstract Superconducting microwave resonators have recently gained a primary importance in the development of cryogenic applications, such as circuit quantum electrodynamics, electron spin resonance spectroscopy and particles detection for high-energy physics and astrophysics. In this work, we investigate the influence of the film thickness on the temperature response of microfabricated Nb 50 Ti 50 superconducting resonators. S-shaped split ring resonators (S-SRRs), approximately 20 nm to 150 nm thick, are designed to be electromagnetically coupled with standard Cu coplanar waveguides (CPWs) and their microwave properties are characterised at temperatures below 10 K . The combined contributions of the kinetic inductance L K ( T ) increase and the decreasing loaded quality factor Q L , for thinner films, induce an optimum condition on the temperature sensitivity and resolution of the resonators. A noise equivalent temperature as low as ( 0.53 ± 0.09 ) μ K Hz − 1 / 2 , at 1 Hz , is reported for 100 nm thick resonators at 4.2 K . We also asses the possibility of implementing a multiplexed frequency readout, allowing for the simultaneous temperature tracking of several sensors along a single CPW. Such results demonstrate the possibility to perform a distributed cryogenic temperature monitoring, with a sub- μ K resolution. Thus, the application of superconducting S-SRRs, eventually benefiting from an even higher