Optics Letters

High-accuracy CPT-based atomic magnetometer with compact optical and electronic architecture

Ruochen Zhang, Renfeng Dai, Hua Liu

Published Sep 23, 2025• 1 citation
Publisher

Abstract

We present a compact CPT-based atomic magnetometer utilizing a directly modulated VCSEL and phase-sensitive detection. The device achieves a static magnetic field measurement accuracy of 20 pT (1σ) with directional consistency exceeding 99.6%. Calibration using saddle and solenoidal coils yields a linear response with coil coefficients of 708.4 nT/mA and 2466.3 nT/mA, respectively, closely matching an optically pumped Mx-type magnetometer. The results validate the feasibility of portable, high-sensitivity CPT magnetometers for real-time vector magnetic field sensing.

DOI
10.1364/ol.572735

Related papers

Compact, high-sensitivity atomic magnetometer utilizing the light-narrowing effect and in-phase excitation

Yuhao Guo, Shuangai Wan, Xiaoguang Sun +1 more

A high-sensitivity optically pumped atomic magnetometer working in the geomagnetic range utilizing the light-narrowing effect and in-phase excitation is described. The setup is based on a simple pump–probe arrangement built around a Cs vapor cell whose active volume is 64 mm3. The transverse oscillating field is applied parallel to the probe beam to drive Zeeman resonance, and the in-phase component of the resonance signal is measured to determine the field. The sensitivity of the magnetometer is improved by pumping most atoms into the stretched state. Consequently, spin-exchange relaxation is suppressed, and a sensitivity of 0.1 pT/Hz1/2 in the range of 10 μT is achieved. This magnetometer has the advantages of large dynamic range, high performance of low-frequency stabilization, high response speed, and compact size. It can be used for many cutting-edge applications such as detection of magnetic anomalies.

Applied Optics•Jan 17, 2019•29 citations

Coherent population trapping-based dual-wavelength modulation system for VCSEL

Jin Li, Dun Qian, Yifan Wang +2 more

Coherent Population Trapping (CPT)-based atomic magnetometers, as a prominent subclass of alkali-metal vapor-cell magnetometers, achieve ultrahigh magnetic-field sensitivity by exploiting an extremely narrow-linewidth optical resonance. A highly stable laser source is a fundamental prerequisite for realizing such performance. Conventionally, when a Vertical-Cavity Surface-Emitting Laser (VCSEL) is employed as the light source in CPT-based atomic magnetometers, its drive electronics rely on discrete benchtop instruments, resulting in bulky systems with limited flexibility and portability. In this work, we present a compact CPT-based dual-wavelength modulation system for the VCSEL. The design integrates a microwave signal generator with excellent phase-noise performance and a high-precision direct current signal source, enabling the generation of a significantly more stable bichromatic optical field. This highly integrated solution addresses the critical demand for robust, lownoise laser sources in a wide range of applications, including quantum sensing and precision measurement, quantum information and computation, as well as fundamental physics research.

International Conference on Computer Technology, Information Engineering, and Electron Materials (CTIEEM)•Apr 8, 2026•0 citations

Miniature Wide-Range Three-Axis Vector Atomic Magnetometer

Jianjun Li, Deng Yicheng, Xuefeng Wang +2 more

A miniature wide-range three-axis vector atomic magnetometer under spin-exchange relaxation-free regime has been developed. With a cylindrical vapor cell of size 10 mm in diameter and length, we have constructed a single-beam configuration through a polarization-maintaining fiber carrying the laser beam to the sensor and a multimode fiber guiding the transmitted light field to the photodiode. A rotating field on the plane perpendicular to the direction of propagation of the laser and another modulation field in the pump direction, which are generated in the field programmable gate array using direct digital synthesis to measure the three components of the magnetic field simultaneously. The spin-exchange relaxation is suppressed in zero field controlled by a feedback system, thus a wide range and excellent accuracy of three-axis vector atomic magnetometer response is obtained. Consequently, the transverse magnetic field sensitivity of 350 fT/Hz1/2and longitudinal field sensitivity of 3pT/Hz1/2are achieved with a dynamic range of 60000 nT. This sensor with compact size, wide range and high sensitivity is particularly suitable for geomagnetic observatory and space exploration.

IEEE Sensors Journal•Sep 13, 2021•14 citations

Loop-locked coherent population trapping magnetometer based on a fiber electro-optic modulator

Yong Hu, Y. Y. Feng, Chi Xu +2 more

We have set up a coherent population trapping (CPT)-based magnetometer prototype with the D1 line of ⁸⁷Rb atoms. The dichromatic light field is derived from a fiber electro-optic modulator (FEOM) connected to an external cavity laser diode. A CPT resonance signal with a 516 Hz linewidth is observed. By feeding back the derivative of the resonance curve to the FEOM with a proportional integral controller, of which the voltage output is directly converted to the measured magnetic field intensity, the resonance peak is locked to the environmental magnetic field. The measurement data we have achieved are well matched with the data measured by a commercial fluxgate magnetometer within 2 nT, and the sensitivity is better than 8 pT/√Hz in a parallel B field.

Applied Optics•Mar 27, 2014•11 citations

Vector magnetometer based on the effect of coherent population trapping

Valeriy Andryushkov, Daba A. Radnatarov, Sergey M Kobtsev

The method is presented for converting a coherent population trapping (CPT) atomic clock into a CPT vector (compass-) magnetometer without mechanically moving parts through a relatively simple add-on. The system of 3D Helmholtz coils was used for compensation of the external magnetic field, allowing measurement of both strength and direction of a magnetic field at the sensitivity level of s u b − n T / H z 1 / 2 within a 10-Hz bandwidth. Angular resolution of the developed vector magnetometer amounts to about 1 0 − 2 degrees.

Applied Optics•Apr 5, 2022•34 citations

On the Development of an Optical Rubidium Vector Atomic Magnetometer

James McKelvy, Irina V. Novikova, Eugeniy E. Mikhailov +6 more

The precise measurement of magnetic fields is a fundamental tool of remote sensing. However, accurately measuring the direction of magnetic fields is challenging with atomic magnetometers. In this work, we discuss progress on the development of an all-optical vector atomic magnetometer that uses electromagnetically induced transparency (EIT) on87Rb vapor. The magnitude of the magnetic field is evaluated by measuring the separation of the laser transmission peaks of the Zeeman-resolved EIT spectra, and the direction is measured by evaluating the relative peak contrast using a lightweight machine learning algorithm involving principal component analysis (PCA). We have demonstrated a scalar sensitivity of $ < 10pT/\sqrt {Hz} $ in the 1–100 Hz band and an angular accuracy of < 1°. This approach for vector magnetometry does not require an array of sensors or calibration coils, ultimately setting the groundwork for the design of a new magnetometer that is lighter and more accurate than conventional vector magnetometer configurations.

IEEE International Geoscience and Remote Sensing Symposium (IGARSS)•Jul 16, 2023•2 citations
We present a compact CPT-based atomic magnetometer utilizing a directly modulated VCSEL and phase-sensitive detection. The device achieves a static magnetic field measurement accuracy of 20 pT (1σ) with directional consistency exceeding 99.6%. Calibration using saddle and solenoidal coils yields a linear response with coil coefficients of 708.4 nT/mA and 2466.3 nT/mA, respectively, closely matching an optically pumped Mx-type magnetometer. The results validate the feasibility of portable, high-sensitivity CPT magnetometers for real-time vector magnetic field sensing.
A high-sensitivity optically pumped atomic magnetometer working in the geomagnetic range utilizing the light-narrowing effect and in-phase excitation is described. The setup is based on a simple pump–probe arrangement built around a Cs vapor cell whose active volume is 64 mm3. The transverse oscillating field is applied parallel to the probe beam to drive Zeeman resonance, and the in-phase component of the resonance signal is measured to determine the field. The sensitivity of the magnetometer is improved by pumping most atoms into the stretched state. Consequently, spin-exchange relaxation is suppressed, and a sensitivity of 0.1 pT/Hz1/2 in the range of 10 μT is achieved. This magnetometer has the advantages of large dynamic range, high performance of low-frequency stabilization, high response speed, and compact size. It can be used for many cutting-edge applications such as detection of magnetic anomalies.
Coherent Population Trapping (CPT)-based atomic magnetometers, as a prominent subclass of alkali-metal vapor-cell magnetometers, achieve ultrahigh magnetic-field sensitivity by exploiting an extremely narrow-linewidth optical resonance. A highly stable laser source is a fundamental prerequisite for realizing such performance. Conventionally, when a Vertical-Cavity Surface-Emitting Laser (VCSEL) is employed as the light source in CPT-based atomic magnetometers, its drive electronics rely on discrete benchtop instruments, resulting in bulky systems with limited flexibility and portability. In this work, we present a compact CPT-based dual-wavelength modulation system for the VCSEL. The design integrates a microwave signal generator with excellent phase-noise performance and a high-precision direct current signal source, enabling the generation of a significantly more stable bichromatic optical field. This highly integrated solution addresses the critical demand for robust, lownoise laser sources in a wide range of applications, including quantum sensing and precision measurement, quantum information and computation, as well as fundamental physics research.
A miniature wide-range three-axis vector atomic magnetometer under spin-exchange relaxation-free regime has been developed. With a cylindrical vapor cell of size 10 mm in diameter and length, we have constructed a single-beam configuration through a polarization-maintaining fiber carrying the laser beam to the sensor and a multimode fiber guiding the transmitted light field to the photodiode. A rotating field on the plane perpendicular to the direction of propagation of the laser and another modulation field in the pump direction, which are generated in the field programmable gate array using direct digital synthesis to measure the three components of the magnetic field simultaneously. The spin-exchange relaxation is suppressed in zero field controlled by a feedback system, thus a wide range and excellent accuracy of three-axis vector atomic magnetometer response is obtained. Consequently, the transverse magnetic field sensitivity of 350 fT/Hz1/2and longitudinal field sensitivity of 3pT/Hz1/2are achieved with a dynamic range of 60000 nT. This sensor with compact size, wide range and high sensitivity is particularly suitable for geomagnetic observatory and space exploration.
We have set up a coherent population trapping (CPT)-based magnetometer prototype with the D1 line of ⁸⁷Rb atoms. The dichromatic light field is derived from a fiber electro-optic modulator (FEOM) connected to an external cavity laser diode. A CPT resonance signal with a 516 Hz linewidth is observed. By feeding back the derivative of the resonance curve to the FEOM with a proportional integral controller, of which the voltage output is directly converted to the measured magnetic field intensity, the resonance peak is locked to the environmental magnetic field. The measurement data we have achieved are well matched with the data measured by a commercial fluxgate magnetometer within 2 nT, and the sensitivity is better than 8 pT/√Hz in a parallel B field.
The method is presented for converting a coherent population trapping (CPT) atomic clock into a CPT vector (compass-) magnetometer without mechanically moving parts through a relatively simple add-on. The system of 3D Helmholtz coils was used for compensation of the external magnetic field, allowing measurement of both strength and direction of a magnetic field at the sensitivity level of s u b − n T / H z 1 / 2 within a 10-Hz bandwidth. Angular resolution of the developed vector magnetometer amounts to about 1 0 − 2 degrees.
The precise measurement of magnetic fields is a fundamental tool of remote sensing. However, accurately measuring the direction of magnetic fields is challenging with atomic magnetometers. In this work, we discuss progress on the development of an all-optical vector atomic magnetometer that uses electromagnetically induced transparency (EIT) on87Rb vapor. The magnitude of the magnetic field is evaluated by measuring the separation of the laser transmission peaks of the Zeeman-resolved EIT spectra, and the direction is measured by evaluating the relative peak contrast using a lightweight machine learning algorithm involving principal component analysis (PCA). We have demonstrated a scalar sensitivity of $ < 10pT/\sqrt {Hz} $ in the 1–100 Hz band and an angular accuracy of < 1°. This approach for vector magnetometry does not require an array of sensors or calibration coils, ultimately setting the groundwork for the design of a new magnetometer that is lighter and more accurate than conventional vector magnetometer configurations.