Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE

Progress toward a single ytterbium ion optical clock

Paul Taylor, Stephen A. Webster, Matthew Roberts, W. R. C. Rowley, G. P. Barwood, Patrick Robert Gill

Published May 3, 2001• 0 citations
Publisher

Abstract

Forbidden transitions in single trapped ion systems are being considered as references for future optical frequency standards. These standards are expected to have application as highly stable and reproducible optical clocks, realizations of the metre and as optical frequency standards in their own right. This paper prescribes the work carried out at the National Physical Laboratory over recent years to use a highly forbidden 2S1/2 - 2F7/2 467 nm electric octupole transition in a single ion of 171Yb+ as a frequency reference. A review of the previous measurements needed to the locate octupole transition in this 171-isotope is given and a more detailed discussion of recent work is presented. This includes spectroscopy of the octupole transition with kilohertz resolution and a direct measurement of its optical frequency. Measurements of the dynamic Stark and the quadratic Zeeman shifts on the octupole frequency are also discussed.

DOI
10.1117/12.424465

Related papers

A TRAPPED 171 Yb + ION OPTICAL FREQUENCY STANDARD BASED ON THE S 1/2 - F 7/2 TRANSITION

P. GILL, Stephen A. Webster, G. HUANG +7 more

The single cold 171 Yb + ion has two optical clock transitions available. One of these is the 2 S 1/2 - 2 D 3/2 quadrupole (E2) transition at 436 nm. The other is the 2 S 1/2 - 2 F 7/2 octupole (E3) transition at 467 nm, which has an extremely narrow theoretical linewidth on account of the 6-year lifetime of its F 7/2 upper level. This paper reports progress on both these clock transitions at NPL. In particular, the absolute frequency of the observed octupole transition has recently been measured with an uncertainty of 12 Hz (1σ) for an octupole linewidth of < 40 Hz. Contributions from major shifts such as the AC Stark shift and second order Zeeman shift have been measured, and quadrupole and blackbody shifts estimated. The frequency ratio between the 171 Yb + quadrupole and octupole transitions demonstrates one of the largest sensitivities for monitoring possible time variation of the fine structure constant. Ultra-stable probe laser light at 436 nm has recently been generated to interrogate the quadrupole clock transition, in preparation for measuring both clock transitions simultaneously.

Symposium on Frequency Standards and Metrology•May 1, 2009•0 citations

Precision frequency measurement of the 2S1/2 — 2F7/2 electric octupole transition in a single 171Yb+ ion

Stephen A. Webster, Kazumoto Hosaka, Barney Walton +2 more

We report precision laser spectroscopy of the2S1/2(F = 0, mF=0)-2F7/2(F =3, mF= 0) clock transition in a single, trapped, laser cooled ion of171Yb+. The absolute frequency is measured to be 642 121 496 772 656 (12) Hz, a factor of 20 more accurate than previous measurements.

Conference on Precision Electromagnetic Measurements•Jun 1, 2008•5 citations

High-Accuracy Optical Clock Based on the Octupole Transition in Yb+171

Nils Huntemann, Maksim V. Okhapkin, B. Lipphardt +3 more

We experimentally investigate an optical frequency standard based on the 467 nm (642 THz) electric-octupole reference transition (2)S(1/2)(F=0)→(2)F(7/2)(F=3) in a single trapped (171)Yb(+) ion. The extraordinary features of this transition result from the long natural lifetime and from the 4f(13)6s(2) configuration of the upper state. The electric-quadrupole moment of the (2)F(7/2) state is measured as -0.041(5)ea(0)(2), where e is the elementary charge and a(0) the Bohr radius. We also obtain information on the differential scalar and tensorial components of the static polarizability and of the probe-light-induced ac Stark shift of the octupole transition. With a real-time extrapolation scheme that eliminates this shift, the unperturbed transition frequency is realized with a fractional uncertainty of 7.1×10(-17). The frequency is measured as 642 121 496 772 645.15(52) Hz.

arXiv:1111.2446•Physical Review Letters•Feb 29, 2012•252 citations

Trapped ion optical frequency standards

Patrick Robert Gill, G. P. Barwood, Hugh A. Klein +6 more

Optical frequency standards based on narrow absorptions in laser-cooled single trapped ions have recently begun to demonstrate stabilities that are competitive with cold atom fountain microwave standards. This paper presents a short review of the wider state-of-the-art development of these single cold trapped ion frequency standards, coupled with a more detailed account of recent results achieved at National Physical Laboratory in respect of single ion systems based on 88Sr+, 87Sr+ and 171Yb+. Narrow linewidth data for the optical clock quadrupole and octupole transitions respectively at 674 nm in 88Sr+ and 467 nm in 171Yb+, are presented, together with a discussion of current systematics and future projections. The potential for optical clock operation is outlined.

Measurement Science and Technology•Jul 16, 2003•44 citations

Kilohertz-resolution spectroscopy of the 2S1/2−2F7/2 electric octupole transition in a single 171Yb+ ion

Stephen A. Webster, Philip H. Taylor, M. Roberts +2 more

Spectroscopy has been performed on $\mathrm{the}{}^{2}{S}_{1/2}(F=0,{m}_{F}{=0)\ensuremath{-}}^{2}{F}_{7/2}{(F=3,m}_{F}=0)$ electric octupole transition in ${}^{171}{\mathrm{Yb}}^{+}$ with kilohertz resolution. A quantum jump rate of more than one per second has been achieved, a factor of 100 improvement on previous work. Spectra including the sidebands at the trap secular frequency show the ion to be in the Lambe-Dicke regime and hence the Doppler effect has been eliminated to first order. The dynamic Stark shift is a significant perturbation to the frequency because of the high intensity required to drive the octupole transition. It has been measured as ${42}_{\ensuremath{-}10}^{+12} \ensuremath{\mu}\mathrm{Hz}{\mathrm{W}}^{\ensuremath{-}1}{\mathrm{m}}^{2}$ and with further reduction in the probe laser linewidth, it should be possible to reduce the relative uncertainty in this shift to the parts in ${10}^{18}$ level. The transition is free from the Zeeman effect to first order and has a measured second-order shift of $1.9(3) \mathrm{mHz}(\ensuremath{\mu}\mathrm{T}{)}^{\ensuremath{-}2}.$ It should be possible to reduce the relative uncertainty in this shift to below the part in ${10}^{18}$ level. The electric quadrupole shift may be the limiting systematic effect, but cannot yet be observed with the current resolution on the transition.

Physical Review A•Apr 15, 2002•33 citations

Optical frequency standards and clocks based on single trapped ions

Helen S. Margolis, G. P. Barwood, Kazumoto Hosaka +6 more

Forbidden transitions in single laser-cooled trapped ions provide highly stable and accurate references for optical frequency standards. This paper describes recent progress on strontium and ytterbium ion optical frequency standards under development at NPL.

Conference on Lasers and Electro-Optics•Jan 1, 2006•0 citations
Forbidden transitions in single trapped ion systems are being considered as references for future optical frequency standards. These standards are expected to have application as highly stable and reproducible optical clocks, realizations of the metre and as optical frequency standards in their own right. This paper prescribes the work carried out at the National Physical Laboratory over recent years to use a highly forbidden 2S1/2 - 2F7/2 467 nm electric octupole transition in a single ion of 171Yb+ as a frequency reference. A review of the previous measurements needed to the locate octupole transition in this 171-isotope is given and a more detailed discussion of recent work is presented. This includes spectroscopy of the octupole transition with kilohertz resolution and a direct measurement of its optical frequency. Measurements of the dynamic Stark and the quadratic Zeeman shifts on the octupole frequency are also discussed.
The single cold 171 Yb + ion has two optical clock transitions available. One of these is the 2 S 1/2 - 2 D 3/2 quadrupole (E2) transition at 436 nm. The other is the 2 S 1/2 - 2 F 7/2 octupole (E3) transition at 467 nm, which has an extremely narrow theoretical linewidth on account of the 6-year lifetime of its F 7/2 upper level. This paper reports progress on both these clock transitions at NPL. In particular, the absolute frequency of the observed octupole transition has recently been measured with an uncertainty of 12 Hz (1σ) for an octupole linewidth of < 40 Hz. Contributions from major shifts such as the AC Stark shift and second order Zeeman shift have been measured, and quadrupole and blackbody shifts estimated. The frequency ratio between the 171 Yb + quadrupole and octupole transitions demonstrates one of the largest sensitivities for monitoring possible time variation of the fine structure constant. Ultra-stable probe laser light at 436 nm has recently been generated to interrogate the quadrupole clock transition, in preparation for measuring both clock transitions simultaneously.
We experimentally investigate an optical frequency standard based on the 467 nm (642 THz) electric-octupole reference transition (2)S(1/2)(F=0)→(2)F(7/2)(F=3) in a single trapped (171)Yb(+) ion. The extraordinary features of this transition result from the long natural lifetime and from the 4f(13)6s(2) configuration of the upper state. The electric-quadrupole moment of the (2)F(7/2) state is measured as -0.041(5)ea(0)(2), where e is the elementary charge and a(0) the Bohr radius. We also obtain information on the differential scalar and tensorial components of the static polarizability and of the probe-light-induced ac Stark shift of the octupole transition. With a real-time extrapolation scheme that eliminates this shift, the unperturbed transition frequency is realized with a fractional uncertainty of 7.1×10(-17). The frequency is measured as 642 121 496 772 645.15(52) Hz.
Optical frequency standards based on narrow absorptions in laser-cooled single trapped ions have recently begun to demonstrate stabilities that are competitive with cold atom fountain microwave standards. This paper presents a short review of the wider state-of-the-art development of these single cold trapped ion frequency standards, coupled with a more detailed account of recent results achieved at National Physical Laboratory in respect of single ion systems based on 88Sr+, 87Sr+ and 171Yb+. Narrow linewidth data for the optical clock quadrupole and octupole transitions respectively at 674 nm in 88Sr+ and 467 nm in 171Yb+, are presented, together with a discussion of current systematics and future projections. The potential for optical clock operation is outlined.
Spectroscopy has been performed on $\mathrm{the}{}^{2}{S}_{1/2}(F=0,{m}_{F}{=0)\ensuremath{-}}^{2}{F}_{7/2}{(F=3,m}_{F}=0)$ electric octupole transition in 171Yb+{}^{171}{\mathrm{Yb}}^{+}171Yb+ with kilohertz resolution. A quantum jump rate of more than one per second has been achieved, a factor of 100 improvement on previous work. Spectra including the sidebands at the trap secular frequency show the ion to be in the Lambe-Dicke regime and hence the Doppler effect has been eliminated to first order. The dynamic Stark shift is a significant perturbation to the frequency because of the high intensity required to drive the octupole transition. It has been measured as ${42}_{\ensuremath{-}10}^{+12} \ensuremath{\mu}\mathrm{Hz}{\mathrm{W}}^{\ensuremath{-}1}{\mathrm{m}}^{2}$ and with further reduction in the probe laser linewidth, it should be possible to reduce the relative uncertainty in this shift to the parts in 1018{10}^{18}1018 level. The transition is free from the Zeeman effect to first order and has a measured second-order shift of $1.9(3) \mathrm{mHz}(\ensuremath{\mu}\mathrm{T}{)}^{\ensuremath{-}2}.$ It should be possible to reduce the relative uncertainty in this shift to below the part in 1018{10}^{18}1018 level. The electric quadrupole shift may be the limiting systematic effect, but cannot yet be observed with the current resolution on the transition.