Nitrogen vacancy (NV) diamonds are promising room temperature quantum sensors. As the technology moves towards application, efficient use of energy and cost become critical for miniaturization. This work focuses on microwave-based spin control using the short-circuited end of a slot line, analyzed by finite element method (FEM) for magnetic field amplitude and uniformity. A microstrip-to-slot-line converter with a −10 dB bandwidth of 3.2 GHz was implemented. Rabi oscillation measurements with an NV microdiamond on a glass fiber show uniform excitation over 1.5 MHz across the slot, allowing spin manipulation within the coherence time of the NV center.
Nitrogen vacancy (NV) diamonds are promising room temperature quantum sensors. As the technology moves towards application, efficient use of energy and cost become critical for miniaturization. This work focuses on microwave-based spin control using the short-circuited end of a slot line, analyzed by finite element method (FEM) for magnetic field amplitude and uniformity. A microstrip-to-slot-line converter with a −10 dB bandwidth of 3.2 GHz was implemented. Rabi oscillation measurements with an NV microdiamond on a glass fiber show uniform excitation over 1.5 MHz across the slot, allowing spin manipulation within the coherence time of the NV center.
Individual nitrogen vacancy (NV) color centers in diamond are versatile, spin-based quantum sensors. Coherently controlling the spin of NV centers using microwaves in a typical frequency range between 2.5 and 3.5 GHz is necessary for sensing applications. In this work, we present a stripline-based, planar, Ω-shaped microwave antenna that enables one to reliably manipulate NV spins. We found an optimal antenna design using finite integral simulations. We fabricated our antennas on low-cost, transparent glass substrate. We created highly uniform microwave fields in areas of roughly 400 × 400 μm2 while realizing high Rabi frequencies of up to 10 MHz in an ensemble of NV centers.
For quantum sensing based on nitrogen-vacancies (NV) ensembles, microwave antennas can couple the microwave field to the NV center, which leads it to becoming the core of spin manipulation and can directly affect the sensitivity of quantum sensing. The double split-ring resonator is a widely used microwave device for NV ensembles due to the advantages of high radiation efficiency and uniform magnetic field in millimeter-scale areas. But the bandwidth (30 MHz) is quite narrow which limits the application in quantum sensing with NV ensembles. Here, we experimentally achieve continuous tuning of the resonant frequency of the double split-ring resonator by changing the copper sheet position on the edge of the outer ring. The frequency tuning range can reach 80 MHz, up to 2-3 times the bandwidth, which can cover the transition of the electron spin under different magnetic field conditions. The performance of the tunable antenna in the quantum operation of NV centers is verified by optically detected magnetic resonance and Rabi oscillation. This tunable antenna is promising in the fabrication of integrated and arrayed quantum sensors based on NV ensembles.
Quantum sensors based on nitrogen-vacancy (NV) centers in diamond are expected to demonstrate a wide variety of applications. For high-sensitivity quantum sensors with NV center ensembles, uniform manipulation of the electron spins of the NV centers in large volumes is required. In addition, a broad microwave frequency bandwidth for manipulating the NV centers' electron spin is necessary for vector magnetometry and measurement under a finite static magnetic field. Here, we demonstrate a broadband microwave antenna for uniform manipulation of millimeter-scale volumes of diamond quantum sensors. The simulation shows that the current is distributed at both edges of the loop coil of a single copper plate due to the skin effect. The loop coil acts like a Helmholtz coil, which realizes uniformity in the z-direction of the microwave magnetic field (B1). The plate structure has a higher mechanical stability, durability, and a larger heat capacity than the Helmholtz coil, due to its large volume. The antenna achieves a higher performance than previously reported antennae, with a maximal B1 of 4.5 G, a broad bandwidth of 287 ± 6 MHz, and a peak-to-peak variation of 9.2% over a 3.1 mm3 cylinder volume. These performances show that the presented antenna is suitable for manipulating solid-state spin ensembles for high-sensitivity quantum sensors.
Nitrogen-Vacancy (NV) centers in diamond are attractive tools for sensing and quantum information. Realization of this potential requires effective tools for controlling the spin degree of freedom by microwave (mw) magnetic fields. In this work, we present a planar microwave resonator optimized for microwave-optical double resonance experiments on single NV centers in diamond. It consists of a piece of wide microstrip line, which is symmetrically connected to two 50 Ω microstrip feed lines. In the center of the resonator, an Ω-shaped loop focuses the current and the mw magnetic field. It generates a relatively homogeneous magnetic field over a volume of 0.07 × 0.1 mm3. It can be operated at 2.9 GHz in both transmission and reflection modes with bandwidths of 1000 and 400 MHz, respectively. The high power-to-magnetic field conversion efficiency allows us to produce π-pulses with a duration of 50 ns with only about 200 and 50 mW microwave power in transmission and reflection, respectively. The transmission mode also offers capability for efficient radio frequency excitation. The resonance frequency can be tuned between 1.3 and 6 GHz by adjusting the length of the resonator. This will be useful for experiments on NV-centers at higher external magnetic fields and on different types of optically active spin centers.
An integrated quantum probe for magnetic field imaging is proposed, where the nitrogen–vacancy (NV) center fixed at the fiber tip is located on the periphery of flexible ring resonator. Using flexible polyimide (PI) as the substrate medium, we design a circular microstrip antenna, which can achieve a bandwidth of 140 MHz at Zeeman splitting frequency of 2.87 GHz, specifically suitable for NV center experiments. Subsequently, this antenna is seamlessly fixed at a three-dimensional-printed cylindrical support, allowing the optical fiber tip to extend out of a dedicated aperture. To mitigate errors originating from processing, precise tuning within a narrow range can be achieved by adjusting the conformal amplitude. Finally, we image the microwave magnetic field around the integrated probe with high resolution, and determine the suitable area for placing the fiber tip (SAP).
This thesis investigates the theoretical foundations, material properties, and experimental realization of quantum sensors based on the Nitrogen-Vacancy (NV) centers in diamond, a solid-state system that combines quantum coherence with room-temperature operability. The first chapter introduces the principles of quantum sensing, outlining the fundamental definitions, operating protocols, and physical processes underlying the quantum measurement paradigm. Emphasis is placed on the quantum sensing Hamiltonian and the distinction between various classes of quantum sensors. The second chapter focuses on diamond as a host material and on the NV center as a quantum defect. The electronic structure, optical transitions, and spin properties of the NV center are analyzed in detail. Several techniques of NV-based magnetometry are presented, including continuouswave and pulsed optically detected magnetic resonance (ODMR). The discussion also addresses coherence times (T1, T2, and T∗2 ) and methods of diamond synthesis together with NV-center generation through irradiation and annealing. Chapter three develops the physical theory describing the NV center. The Hamiltonian formalism includes spin-spin, hyperfine, and quadrupolar interactions, as well as couplings to external magnetic fields. The chapter further introduces the Bloch sphere representation, magnetic resonance phenomena, and models of lightmatter interaction, ranging from the semiclassical to the fully quantum Rabi framework. A seven-level rate-equation model is proposed to capture the spin dynamics and optical cycling processes of the NV center. The fourth chapter reports the experimental results. After describing materials and methods, several ODMR-based vector magnetometry experiments are presented, highlighting different spectral regimes and the dependence of resonance features on the external magnetic field geometry. Additional studies demonstrate temperature sensing and microwave-free magnetometry techniques for mapping magnetic field distributions. Sensitivity analysis and calibration procedures are also discussed.