Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Radiophysics and Quantum Electronics

INJECTION LOCKING FOR SPECTRAL FILTERING OF ADDRESSING LASER FOR OPTICAL QUBITS IN $^{171}$Yb$^+$ IONS

Kristina P. Galstyan, Ilia V. Zalivako, D. S. Kryuchkov, N. Kolachevsky

Published Jan 1, 2024• 0 citations
Publisher
DOI
10.52452/00213462_2024_67_1_15

Related papers

INJECTION LOCKING FOR SPECTRAL FILTERING OF ADDRESSING LASER FOR OPTICAL QUBITS IN $^{171}$Yb$^+$ IONS

Kristina P. Galstyan, Ilia V. Zalivako, D. S. Kryuchkov +1 more

Radiophysics and Quantum Electronics•Jan 1, 2024•1 citation

SUB-QUADRATIC TOKEN MIXING VIA SPECTRAL FILTERING AND POLYNOMIAL FUNCTIONAL CALCULUS

Shafiq Hussain,Muhammad Usman Ahmad,Muhammad Arman,Farhan Majeed,Tauqir Ahmad,Tahreem Fatima,Aleena Jamil,Adeen Amjad,Waqar Ahmad,Arslan Ali Mansab,Muhammad Hamza,Muhammad Waqas

•Jun 26, 2025•0 citations

Injection Locking for Spectral Filtering of the Addressing Laser for Optical Qubits in 171Yb+ Ions

Kristina P. Galstyan, Ilia V. Zalivako, D. S. Kryuchkov +1 more

Radiophysics and Quantum Electronics•Jun 1, 2024•7 citations

An injection-locked 1762 nm laser for trapped barium ion qubits

Tarun Dutta

Applied Physics B•Jun 30, 2022•4 citations

INVESTIGATION OF THE MAGNETO-OPTICAL PROPERTIES OF RARE-EARTH IONS

Anvar Karimovich Muxammadiyev, Nafisa Ineoyatovna Jurayeva

Scientific Bulletin of Namangan State University•Jan 1, 2019•0 citations

A MICROWAVE FREQUENCY STANDARD BASED ON LASER-COOLED 171 Yb + IONS

Richard B. Warrington, Peter Fisk, Michael J. Wouters +1 more

We report the first operation of a microwave frequency standard based on the 12.6 GHz ground-state hyperfine transition in a cloud of laser-cooled 171 Yb + ions, with a preliminary measurement of the transition frequency. We obtain 12 642 812 118.468 5(7)(6) Hz, where the first uncertainty combines statistical uncertainty and the uncertainty of the systematic shifts in the transition frequency due to the trap environment, and the second is that of a comparison between a reference hydrogen maser and the SI second. This value is in agreement with earlier measurements obtained for buffer gas-cooled ions where the second-order Doppler shift is 180 times larger. A full evaluation of systematic shifts is still pending, but the dominant effects are discussed. Motional second-order Doppler shifts are determined within an uncertainty of 1–2 parts in 10 15 from measurements of the ion temperature. Our progress to date indicates no serious obstacle to realising a combined fractional frequency uncertainty of 4 × 10 -15 or smaller and a projected stability of approximately 5 × 10 -14 τ -1/2 for a 10 s Ramsey time. The performance of the 171 Yb + microwave standard can therefore be comparable to that of a cesium fountain.

Symposium on Frequency Standards and Metrology•May 1, 2002•11 citations
INJECTION LOCKING FOR SPECTRAL FILTERING OF ADDRESSING LASER FOR OPTICAL QUBITS IN 171^{171}171Yb+^++ IONS
INJECTION LOCKING FOR SPECTRAL FILTERING OF ADDRESSING LASER FOR OPTICAL QUBITS IN 171^{171}171Yb+^++ IONS
We report the first operation of a microwave frequency standard based on the 12.6 GHz ground-state hyperfine transition in a cloud of laser-cooled 171 Yb + ions, with a preliminary measurement of the transition frequency. We obtain 12 642 812 118.468 5(7)(6) Hz, where the first uncertainty combines statistical uncertainty and the uncertainty of the systematic shifts in the transition frequency due to the trap environment, and the second is that of a comparison between a reference hydrogen maser and the SI second. This value is in agreement with earlier measurements obtained for buffer gas-cooled ions where the second-order Doppler shift is 180 times larger. A full evaluation of systematic shifts is still pending, but the dominant effects are discussed. Motional second-order Doppler shifts are determined within an uncertainty of 1–2 parts in 10 15 from measurements of the ion temperature. Our progress to date indicates no serious obstacle to realising a combined fractional frequency uncertainty of 4 × 10 -15 or smaller and a projected stability of approximately 5 × 10 -14 τ -1/2 for a 10 s Ramsey time. The performance of the 171 Yb + microwave standard can therefore be comparable to that of a cesium fountain.