Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Symposium on Frequency Standards and Metrology

A MICROWAVE FREQUENCY STANDARD BASED ON LASER-COOLED 171 Yb + IONS

Richard B. Warrington, Peter Fisk, Michael J. Wouters, M.A. Lawn

Published May 1, 2002• 11 citations
Publisher

Abstract

We report the first operation of a microwave frequency standard based on the 12.6 GHz ground-state hyperfine transition in a cloud of laser-cooled 171 Yb + ions, with a preliminary measurement of the transition frequency. We obtain 12 642 812 118.468 5(7)(6) Hz, where the first uncertainty combines statistical uncertainty and the uncertainty of the systematic shifts in the transition frequency due to the trap environment, and the second is that of a comparison between a reference hydrogen maser and the SI second. This value is in agreement with earlier measurements obtained for buffer gas-cooled ions where the second-order Doppler shift is 180 times larger. A full evaluation of systematic shifts is still pending, but the dominant effects are discussed. Motional second-order Doppler shifts are determined within an uncertainty of 1–2 parts in 10 15 from measurements of the ion temperature. Our progress to date indicates no serious obstacle to realising a combined fractional frequency uncertainty of 4 × 10 -15 or smaller and a projected stability of approximately 5 × 10 -14 τ -1/2 for a 10 s Ramsey time. The performance of the 171 Yb + microwave standard can therefore be comparable to that of a cesium fountain.

DOI
10.1142/9789812777713_0033

Related papers

A microwave frequency standard based on laser-cooled /sup 171/Yb/sup +/ ions

Richard B. Warrington, Peter Fisk, Michael J. Wouters +1 more

We report operation of a microwave frequency standard based on the 12.6 GHz ground-state hyperfine transition in a cloud of laser-cooled /sup 171/Yb/sup +/ ions. The projected performance of this standard (frequency uncertainty /spl les/ 4 /spl times/ 10/sup -15/ and stability 5 /spl times/ 10/sup -14/ /spl tau//sup -1/2/ for a 10 s Ramsey time) is comparable to that of a cesium fountain.

Conference on Precision Electromagnetic Measurements•Jun 25, 2003•0 citations

Progress at CSIRO Australia towards a microwave frequency standard based on trapped, laser-cooled /sup 171/Yb/sup +/ ions

Peter Fisk, M.A. Lawn, C. Coles

The authors report preliminary results of precision microwave-optical double resonance spectroscopy on buffer gas cooled /sup 171/Yb/sup +/ ions confined in a linear Paul trap as a microwave frequency standard at 12.6 GHz. They also report laser cooling of trapped /sup 171/Yb/sup +/ ions. Temperatures below 1 K have been achieved, and evidence for a phase transition to a crystal-like state has been found. This temperature is sufficiently low to reduce the fractional second-order Doppler shift of the microwave resonance to below 10/sup -14/.>

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Dec 30, 2002•1 citation

High-accuracy frequency standards using laser-cooled Hg+ ions

Dana J. Berkeland, J.D. Miller, Brent C. Young +3 more

We discuss frequency standards based on laser-cooled 199Hg+ ions confined in cryogenic rf traps. In one experiment, the frequency of a microwave source is served to the ions' ground-state hyperfine transition at 40.5 GHz. For seven ions and a Ramsey free precession time of 100 s, the fractional frequency stability is 3.3 (2) X 10-13 (tau) -1/2 for measurement times (tau) < 2 h. The ground-state hyperfine interval is measured to be 40 507 347 996.841 59 (14) (41) Hz, where the first number in parentheses is the uncertainty due to statistics and systematic errors, and the second is the uncertainty in the frequency of the time scale to which the standard is compared. In a second experiment under development, a strong-binding cryogenic trap will confine a single ion used for an optical frequency standard based on a narrow electric quadrupole transition at 282 nm. The bandwidth of the laser used to drive this transition is less than 10 Hz at 563 nm.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•May 15, 1998•1 citation

Laser-cooled 171 Yb + microwave clock with a systematic uncertainty of 7.8×10 −15

Yong Chen, Y. Zheng, S. N. Miao +4 more

We present a transportable laser-cooled ion microwave clock based on the ground-state hyperfine splitting of 171 Yb + . The system achieves a systematic uncertainty of 7.8×10 −15 and a short-term frequency stability of 9.5×10 −13 / τ . Enhancements to the magnetic-field system suppress the decoherence process in the multi-body ion ensemble and reduce the second-order Zeeman frequency shift by a factor of two. The absolute microwave frequency is measured to be 12 642 812 118.468 6(3) Hz, consistent with the previous measurements and demonstrating twice the precision of the current state-of-the-art.

Optics Letters•Aug 28, 2025•2 citations

Microwave-optical double resonance on a single laser-cooled 171 Yb + ion

V. Enclers, Ph. W. Courteille, R. Huesmann +4 more

The ground-state hyperfine transitions of trapped clouds of 9Be+, 201Hg+, and 171Yb ions have been made control microwave oscillators.1-5 The frequency stability of these atomic clocks exceeds that of a primary Cs frequency standard in the short-term regime and that of a hydrogen maser for long times. Systematic perturbations derive from the members of the cloud being placed in an inhomogeneous field and showing residual motion. A single cold ion kept in the field node of an electrodynamic trap lacks these perturbations. The precise control of a standard frequency requires a narrow and weak transition whose resonance can be hardly detected by observation of the fluorescence on this line.

•May 8, 1994•1 citation

A Microwave Clock Based on Laser-Cooled 171 Yb + Ions

N. C. Xin, Jianwei Zhang, S. N. Miao +5 more

A microwave frequency standard based on laser-cooled171Yb+ions at Tsinghua University has been investigated. More than 105171Yb+ions were stably trapped for over 40 hours. The ground-state hyperfine splitting frequency of171Yb+was determined to be 12642812118.4672(8) Hz with a fractional frequency uncertainty of 6.33×10−14. Our work is in a continuous line with that of other scholars.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 24, 2022•2 citations
We report the first operation of a microwave frequency standard based on the 12.6 GHz ground-state hyperfine transition in a cloud of laser-cooled 171 Yb + ions, with a preliminary measurement of the transition frequency. We obtain 12 642 812 118.468 5(7)(6) Hz, where the first uncertainty combines statistical uncertainty and the uncertainty of the systematic shifts in the transition frequency due to the trap environment, and the second is that of a comparison between a reference hydrogen maser and the SI second. This value is in agreement with earlier measurements obtained for buffer gas-cooled ions where the second-order Doppler shift is 180 times larger. A full evaluation of systematic shifts is still pending, but the dominant effects are discussed. Motional second-order Doppler shifts are determined within an uncertainty of 1–2 parts in 10 15 from measurements of the ion temperature. Our progress to date indicates no serious obstacle to realising a combined fractional frequency uncertainty of 4 × 10 -15 or smaller and a projected stability of approximately 5 × 10 -14 τ -1/2 for a 10 s Ramsey time. The performance of the 171 Yb + microwave standard can therefore be comparable to that of a cesium fountain.
The authors report preliminary results of precision microwave-optical double resonance spectroscopy on buffer gas cooled /sup 171/Yb/sup +/ ions confined in a linear Paul trap as a microwave frequency standard at 12.6 GHz. They also report laser cooling of trapped /sup 171/Yb/sup +/ ions. Temperatures below 1 K have been achieved, and evidence for a phase transition to a crystal-like state has been found. This temperature is sufficiently low to reduce the fractional second-order Doppler shift of the microwave resonance to below 10/sup -14/.>
We discuss frequency standards based on laser-cooled 199Hg+ ions confined in cryogenic rf traps. In one experiment, the frequency of a microwave source is served to the ions' ground-state hyperfine transition at 40.5 GHz. For seven ions and a Ramsey free precession time of 100 s, the fractional frequency stability is 3.3 (2) X 10-13 (tau) -1/2 for measurement times (tau) < 2 h. The ground-state hyperfine interval is measured to be 40 507 347 996.841 59 (14) (41) Hz, where the first number in parentheses is the uncertainty due to statistics and systematic errors, and the second is the uncertainty in the frequency of the time scale to which the standard is compared. In a second experiment under development, a strong-binding cryogenic trap will confine a single ion used for an optical frequency standard based on a narrow electric quadrupole transition at 282 nm. The bandwidth of the laser used to drive this transition is less than 10 Hz at 563 nm.
We present a transportable laser-cooled ion microwave clock based on the ground-state hyperfine splitting of 171 Yb + . The system achieves a systematic uncertainty of 7.8×10 −15 and a short-term frequency stability of 9.5×10 −13 / τ . Enhancements to the magnetic-field system suppress the decoherence process in the multi-body ion ensemble and reduce the second-order Zeeman frequency shift by a factor of two. The absolute microwave frequency is measured to be 12 642 812 118.468 6(3) Hz, consistent with the previous measurements and demonstrating twice the precision of the current state-of-the-art.
The ground-state hyperfine transitions of trapped clouds of 9Be+, 201Hg+, and 171Yb ions have been made control microwave oscillators.1-5 The frequency stability of these atomic clocks exceeds that of a primary Cs frequency standard in the short-term regime and that of a hydrogen maser for long times. Systematic perturbations derive from the members of the cloud being placed in an inhomogeneous field and showing residual motion. A single cold ion kept in the field node of an electrodynamic trap lacks these perturbations. The precise control of a standard frequency requires a narrow and weak transition whose resonance can be hardly detected by observation of the fluorescence on this line.