Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Communications

Attosecond resolution in birefringence measurement using real weak value

Wenqiang Luo, Yan Wang, Jiawei Liu, Shizhen Chen, Hailu Luo

Published Apr 15, 2025• 1 citation
Publisher
DOI
10.1016/j.optcom.2025.131829

Related papers

Realization of ultra-small stress birefringence detection with weak-value amplification technique

Yongsheng Wang, Shizhen Chen, Shuangchun Wen +1 more

How to realize the detection of tiny birefringence is an important but challenging issue for investigations and applications in optics. In weak measurements, weak-value amplification has been widely applied to the precise estimation of time delay. Here, we show that the linear amplification in weak measurements has the potential to outperform standard weak-value amplification for ultra-small parameter characterization. The higher measurement accuracy in the linear amplification enables us to achieve a measurement of stress-induced birefringence with a high resolution of 5×10−10. Compared with existing methods, the accuracy based on weak measurements for birefringence detection can improve two orders of magnitude. Our method may have important applications in a variety of fields involving the precise measurement of time delay or birefringence.

Applied Physics Letters•Apr 19, 2021•20 citations

Attosecond Measurements via Quantum-Enhanced Interferometry

Spencer J. Johnson, Colin P. Lualdi, Kristina A. Meier +1 more

Bulletin of the American Physical Society•Jun 2, 2021•0 citations

Attosecond resolution

Noriaki Horiuchi

Nature Photonics•Jun 22, 2018•0 citations

Enhancing Interferometry Using Weak Value Amplification with Real Weak Values

Jing-Hui Huang, Kyle M. Jordan, Adetunmise C. Dada +2 more

We introduce an ultrasensitive interferometric protocol that combines weak value amplification (WVA) with traditional interferometry. This protocol WVA+interferometry uses weak value amplification of the relative delay between two paths to enhance interferometric sensitivity. As an example, we demonstrate a proof-of-principle experiment that achieves few-attosecond timing resolution (few nanometer path length resolution) with a double-slit interferometer using only common optical components. Since our example uses only the spatial shift of double-slit interference fringes, its precision is not limited by the timing resolution of the detectors but is instead limited by the fundamental shot noise associated with classical light and the diminished technical noise. We experimentally demonstrate that the signal-to-noise ratio can be improved by one to two orders of magnitude relative to a measurement that does not use WVA. Two key conclusions are drawn: (i) Most conventional interferometric techniques primarily rely on determining the path difference (time delay or longitudinal phase), with their precision constrained by technical noise. Our protocol offers a robust solution for minimizing the technical noise in traditional interferometry, with precision in principle approaching the shot-noise limit. (ii) Although WVA has achieved significant advancements in ultrasensitive longitudinal phase measurement, its applicability is constrained by the need for broad spectral bandwidths and high-resolution spectrometers. Contrary to previous assumptions, we demonstrate that quantum-limited WVA time delay measurements are achievable with narrow band light using real weak values. Thus, the cost-effectiveness and practicality of the proposed WVA+interferometry protocol using narrow band light broaden the scope of WVA applications. This protocol holds potential for broad applications in optical metrology, quantum optics and quantum information, biomedical imaging, and interferometric telescopes for astrophysics.

arXiv:2404.00531•Physical Review Letters•Feb 27, 2025•13 citations

From ultra precise spectroscopy to attosecond physics

Theodor W. Hänsch

•May 16, 2004•0 citations

Differential interference metrology in crystal optics

Rong Wang, Qiang Yang, Xiaohui Ling +1 more

Conventional differential interference contrast (DIC) microscopy is inherently qualitative and lacks metrological capability, whereas high-precision techniques such as weak value amplification impose stringent experimental requirements. Here, we present a compact transmissive differential interferometric measurement system based on a birefringent crystal. By functioning as an interference element, the crystal enables quantitative differential interference measurements in both real space and momentum space. This approach avoids the dependence of weak value amplification on weak coupling and non-orthogonal state selection, while retaining and utilizing the inherent birefringent phase information of the crystal. We propose two modulation strategies and establish a unified theoretical model linking microscopic crystal parameters to macroscopic interferometric observations. Based on this model, the system can achieve an angular resolution on the order of 10−9 rad, which exceeds that of typical commercial polarimeters, and detects displacements as small as 0.35 nm, demonstrating nanometer-scale sensing capability. Owing to its compact design and tunable parameters, this system offers a compact quantitative approach for high-precision applications, including chiral sensing, nanometrology, and quantum material analysis.

Frontiers of Physics•Jan 1, 2026•0 citations
How to realize the detection of tiny birefringence is an important but challenging issue for investigations and applications in optics. In weak measurements, weak-value amplification has been widely applied to the precise estimation of time delay. Here, we show that the linear amplification in weak measurements has the potential to outperform standard weak-value amplification for ultra-small parameter characterization. The higher measurement accuracy in the linear amplification enables us to achieve a measurement of stress-induced birefringence with a high resolution of 5×10−10. Compared with existing methods, the accuracy based on weak measurements for birefringence detection can improve two orders of magnitude. Our method may have important applications in a variety of fields involving the precise measurement of time delay or birefringence.
We introduce an ultrasensitive interferometric protocol that combines weak value amplification (WVA) with traditional interferometry. This protocol WVA+interferometry uses weak value amplification of the relative delay between two paths to enhance interferometric sensitivity. As an example, we demonstrate a proof-of-principle experiment that achieves few-attosecond timing resolution (few nanometer path length resolution) with a double-slit interferometer using only common optical components. Since our example uses only the spatial shift of double-slit interference fringes, its precision is not limited by the timing resolution of the detectors but is instead limited by the fundamental shot noise associated with classical light and the diminished technical noise. We experimentally demonstrate that the signal-to-noise ratio can be improved by one to two orders of magnitude relative to a measurement that does not use WVA. Two key conclusions are drawn: (i) Most conventional interferometric techniques primarily rely on determining the path difference (time delay or longitudinal phase), with their precision constrained by technical noise. Our protocol offers a robust solution for minimizing the technical noise in traditional interferometry, with precision in principle approaching the shot-noise limit. (ii) Although WVA has achieved significant advancements in ultrasensitive longitudinal phase measurement, its applicability is constrained by the need for broad spectral bandwidths and high-resolution spectrometers. Contrary to previous assumptions, we demonstrate that quantum-limited WVA time delay measurements are achievable with narrow band light using real weak values. Thus, the cost-effectiveness and practicality of the proposed WVA+interferometry protocol using narrow band light broaden the scope of WVA applications. This protocol holds potential for broad applications in optical metrology, quantum optics and quantum information, biomedical imaging, and interferometric telescopes for astrophysics.
Conventional differential interference contrast (DIC) microscopy is inherently qualitative and lacks metrological capability, whereas high-precision techniques such as weak value amplification impose stringent experimental requirements. Here, we present a compact transmissive differential interferometric measurement system based on a birefringent crystal. By functioning as an interference element, the crystal enables quantitative differential interference measurements in both real space and momentum space. This approach avoids the dependence of weak value amplification on weak coupling and non-orthogonal state selection, while retaining and utilizing the inherent birefringent phase information of the crystal. We propose two modulation strategies and establish a unified theoretical model linking microscopic crystal parameters to macroscopic interferometric observations. Based on this model, the system can achieve an angular resolution on the order of 10−9 rad, which exceeds that of typical commercial polarimeters, and detects displacements as small as 0.35 nm, demonstrating nanometer-scale sensing capability. Owing to its compact design and tunable parameters, this system offers a compact quantitative approach for high-precision applications, including chiral sensing, nanometrology, and quantum material analysis.