Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Nature Photonics

Attosecond resolution

Noriaki Horiuchi

Published Jun 22, 2018• 0 citations
Publisher
DOI
10.1038/s41566-018-0210-8

Related papers

Attosecond resolution in birefringence measurement using real weak value

Wenqiang Luo, Yan Wang, Jiawei Liu +2 more

Optics Communications•Apr 15, 2025•1 citation

Attosecond splits in atoms

Tony Scully

Nature Middle East•Jul 26, 2010•0 citations

Driven Atoms and Molecules as Coherent Attosecond Waveform Processors

Asaf Farhi

Advancing temporal resolution in computation, signal modulation, and quantum measurement is fundamentally constrained in optical resonator platforms by a trade-off between operation time and temporal resolution. We show that driven atomic and molecular systems perform temporal integration of resonant pulses via passive coherent absorption or stimulated emission, enabling attosecond resolution together with long operation time. We derive an analytic description of this mechanism through Bloch equations and time-dependent Schrodinger equation, finding quantitative agreement. We further identify feasible atomic transitions and excitation schemes accessible with current technology, and describe implementations for temporal differentiation and waveform generation at attosecond resolution. These results establish driven quantum transitions as a framework for attosecond-scale waveform processing beyond conventional resonator approaches, with potential applications in computation, optical switching, system control, and data transfer.

arXiv:2506.03482•Jun 4, 2025•0 citations

Applications of Attosecond Pulses

Zenghu Chang

CRC Press eBooks•Apr 19, 2016•0 citations

Photoionization study using few attosecond pulses and coincidence imaging techniques

Lisa Rämisch

Photoionization is one of the most fundamental photoreactions that leads to the ejection of an electron and the formation of an ion. With the help of modern 3D momentum imaging spectrometers, the interplay between the time and frequency domain upon ionization is studied. In this work, single photoionization of helium is investigated in the few-cycle pulse regime of the driving infrared laser pulses with ultrashort attosecond pulses in a dressing infrared field. By varying the carrier-to-envelope phase of the infrared field to modify the spectro-temporal structure of the attosecond pulses, we analyze how the infrared field impacts the measured angularly-resolved photoelectron energy distribution. To this end, a newly built coincidence 3D momentum spectrometer was used. A thorough understanding of the experiment is achieved by using simulations within the strong field approximation. This analysis allows us to separate our observation into two scenarios, one at two attosecond pulses when the carrier-to-envelope phase is $\pi/2$ and the second one at three attosecond pulses when the carrier-to-envelope phase is 0 or $\pi$. When the dressing infrared field is added, the photoelectron spectrum changes in comparison to photoionization with attosecond pulses only. While two attosecond pulses in the dressing infrared field modify the photoelectron spectrum in a continuous way, we observe sidebands appearing in the spectrum generated by three pulses in the dressing infrared field. Finally, the resolution of the spectrometer is studied before and after an upgrade of the spectrometer was performed in the context of this work. This study allows us to understand the limiting factors of the energy resolution. In particular, it shows that the resolution is essentially limited by the source volume of the emitted particles, while the magnetic field does not limit the resolution as it was expected.

•Jan 1, 2019•0 citations

Attosecond control of electron dynamics

Matthias F. Kling

Bulletin of the American Physical Society•Jun 6, 2007•0 citations
Advancing temporal resolution in computation, signal modulation, and quantum measurement is fundamentally constrained in optical resonator platforms by a trade-off between operation time and temporal resolution. We show that driven atomic and molecular systems perform temporal integration of resonant pulses via passive coherent absorption or stimulated emission, enabling attosecond resolution together with long operation time. We derive an analytic description of this mechanism through Bloch equations and time-dependent Schrodinger equation, finding quantitative agreement. We further identify feasible atomic transitions and excitation schemes accessible with current technology, and describe implementations for temporal differentiation and waveform generation at attosecond resolution. These results establish driven quantum transitions as a framework for attosecond-scale waveform processing beyond conventional resonator approaches, with potential applications in computation, optical switching, system control, and data transfer.
Photoionization is one of the most fundamental photoreactions that leads to the ejection of an electron and the formation of an ion. With the help of modern 3D momentum imaging spectrometers, the interplay between the time and frequency domain upon ionization is studied. In this work, single photoionization of helium is investigated in the few-cycle pulse regime of the driving infrared laser pulses with ultrashort attosecond pulses in a dressing infrared field. By varying the carrier-to-envelope phase of the infrared field to modify the spectro-temporal structure of the attosecond pulses, we analyze how the infrared field impacts the measured angularly-resolved photoelectron energy distribution. To this end, a newly built coincidence 3D momentum spectrometer was used. A thorough understanding of the experiment is achieved by using simulations within the strong field approximation. This analysis allows us to separate our observation into two scenarios, one at two attosecond pulses when the carrier-to-envelope phase is π/2\pi/2π/2 and the second one at three attosecond pulses when the carrier-to-envelope phase is 0 or π\piπ. When the dressing infrared field is added, the photoelectron spectrum changes in comparison to photoionization with attosecond pulses only. While two attosecond pulses in the dressing infrared field modify the photoelectron spectrum in a continuous way, we observe sidebands appearing in the spectrum generated by three pulses in the dressing infrared field. Finally, the resolution of the spectrometer is studied before and after an upgrade of the spectrometer was performed in the context of this work. This study allows us to understand the limiting factors of the energy resolution. In particular, it shows that the resolution is essentially limited by the source volume of the emitted particles, while the magnetic field does not limit the resolution as it was expected.