Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Express

Efficient phase-sensitive compensation in lossy interferometry using optical amplification

Tingting Jiang, Jie Zhao, Feiyu Yao, Xinyun Liang, Zeliang Wu, Wenfeng Huang, Yuan Wu, L. Q. Chen

Published Apr 2, 2025• 2 citations
Publisher

Abstract

Optical interferometers, as precision measurement tools, inevitably experience optical path losses in practical applications, which introduce unavoidable vacuum noise and reduce the sensitivity in the phase estimation. To mitigate the effects of losses on sensitivity, we propose an enhanced interferometer scheme that integrates a Raman amplifier. This amplifier is strategically positioned within the lossy interference arm to counteract the reduction in phase sensitivity caused by losses. Our research highlights the crucial role of amplifier positioning, revealing that pre-amplification (PRA, placing the amplifier before the lossy section) significantly outperforms post-amplification (POA, placing the amplifier after the lossy section). PRA effectively enhances sensitivity by increasing the number of phase-sensitive particles and minimizing noise amplification. As the loss increases, the superiority of PRA in mitigating loss effects becomes increasingly evident. To validate our approach, we conducted experimental demonstrations. When the losses reach 90%, PRA experimentally achieves a sensitivity improvement of 4.6 dB compared with the case of only loss without the amplifier, equivalent to increasing the input laser power by over 8 times. PRA can effectively improve the robustness against losses for the practical application solely through the use of a coherent amplifier, with a simple technical implementation yet remarkable enhancement effects. We believe that current PRA-enhanced interferometry facilitates the practical implementation of phase measurement in environments characterized by significant loss.

DOI
10.1364/oe.554274

Related papers

Coherent Amplifier-Empowered Quantum Interferometer: Preserving Sensitivity and Quantum Advantage under High Loss

Jie Zhao, Zeliang Wu, Haoran Liu +6 more

Quantum interferometers offer phase measurement capabilities that surpass the standard quantum limit (SQL), with phase sensitivity and quantum enhancement factor serving as key performance metrics. However, practical implementations face severe degradation of both metrics due to unavoidable losses, representing the foremost challenge in advancing quantum interferometry toward real-world applications. To address this challenge, we propose a coherent-amplifier-empowered quantum interferometer. The coherent amplifier dramatically suppresses the decay of both sensitivity and quantum enhancement under high-loss conditions, maintaining phase sensitivity beyond the original SQL even for losses exceeding 90%. Using an injected 4.2 dB squeezed-vacuum state in experimental demonstration, our scheme reduces the quantum enhancement degradation under 90% loss from 3.7 dB in a conventional quantum interferometer (CQI) to only 1.5 dB. More importantly, the phase sensitivity degradation under the same loss is limited to 4.0 dB, markedly outperforming the 11.2 dB degradation observed in a CQI. This improvement is enabled by the coherent amplifier's phase-sensitive photon amplification and its protection of the quantum state. This breakthrough in amplifier-empowered quantum interferometry overcomes the critical barrier to practical deployment, enabling robust quantum-enhanced measurements in lossy environments.

quant-pharXiv:2601.17876•Jan 27, 2026•0 citations

Mitigating unbalanced loss in entanglement assisted absorptive measurements with a phase-sensitive amplifier

Wei Du, Shidong Bao, Peiyu Yang +5 more

Correlated interferometry offers various advantages in precision measurements, such as sub-shot noise sensitivity, high resolution, and prevention of detector saturation benefiting from dark output. In certain practical scenarios, e.g. absorptive measurement, there is usually unbalanced loss between the probe and reference beams, which destroys the correlation and remains a significant obstacle in the efficient application of entanglements. Here, we study the performance of a nonlinear interferometer whose arms experience unbalanced loss and demonstrate the use of a phase-sensitive amplifier in the sensing or reference arms to amplify or squeeze the light field, which can both reduce the degradation of quantum enhancement from unbalanced absorption in a lossy environment. We find that the loss after amplification, i.e. from imperfect interferometry and detection, can be mitigated when the phase-sensitive amplifier is placed at the sensing arm and functions as a noiseless amplifier. Our approach may be helpful to the practical application of quantum-enhanced absorptive measurement.

Optics Express•Nov 15, 2024•0 citations

Phase-sensitive optomechanical amplifier for quantum noise reduction in laser interferometers

Yuntao Bai, G. Venugopalan, Kevin A. Kuns +5 more

The sensitivity of future gravitational wave interferometers is expected to be limited throughout the detection band by quantum vacuum fluctuations, which can be reduced by applying quantum optics techniques such as squeezed vacuum injection. However, decoherence caused by optical losses in the readout chain will severely limit the effectiveness of such schemes. It was proposed that effect of losses in the final stage of detection can be mitigated by a phase-sensitive amplifier placed in between the output port of the interferometer and the photodetector. In this paper we propose to implement such amplification using an optomechanical device, study some of its practical limitations, and discuss its applicability to next-generation gravitational-wave detectors.

arXiv:1909.02264•Physical Review A•Aug 5, 2020•9 citations

Enhanced resolution in lossy phase estimation by optical parametric amplification

Nicolò Spagnolo, Chiara Vitelli, Lorenzo Toffoli +2 more

In the optical sensing context one of the main challenge is to design and implement novel techniques of sensing optimized to work in a lossy scenario, in which effects of environmental disturbances can destroy the benefits deriving from the adoption of quantum resources. Here we describe the experimental implementation of a protocol based on the process of optical parametric amplification to boost interferometry sensitivity in the presence of losses in a minimally invasive scenario. By performing the amplification process on a microscopic probe after the interaction with the sample, we can beat the losses detrimental effect on the phase measurement which affects the single photon state after its interaction with the sample, and thus improve the achievable sensitivity.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Apr 30, 2011•0 citations

Enhancement of the phase-measurement sensitivity beyond the standard quantum limit by a nonlinear interferometer

Z. Y. Ou

A nonlinear interferometer uses nonlinear elements as beam splitters to split and to recombine optical waves for interference. As a result, the interference fringe size has a nonlinear dependence on the intensity of the field for phase sensing and leads to an enhanced phase signal. In this paper, a practical scheme of nonlinear interferometry for precision phase measurement is analyzed with parametric amplifiers as the nonlinear beam splitters. It is found that the signal due to phase shift is enhanced by a factor of the amplification gain as compared to a linear interferometer with the same phase-sensing light intensity while the quantum noise is kept at the vacuum level, thus, effectively increasing the signal-to-noise ratio (SNR) beyond the standard quantum limit. Furthermore, the scheme is not as sensitive to the detection loss as the linear scheme with a squeezed state for noise reduction. However, losses inside the interferometer limit the enhancement factor in SNR. We apply the concept to a Michelson interferometer but with parametric amplifiers involved for gravitational-wave detection. We find that effective power is increased by the gain of the amplifiers without actually increasing the cycling power inside the interferometer. Furthermore, the full benefits with squeezed input and variational output or the combination of a quantum nondemolition interferometer for sensitivity beyond the standard quantum limit apply here with even better results. Such a nonlinear interferometer will find wide applications in precision measurements.

Physical Review A•Feb 14, 2012•191 citations

Loss-insensitive quantum noise reduction in a Raman amplifier with coherent feedback

Jianmin Wang, Rong Zhu, Z. Y. Ou

A quantum amplifier usually adds extra noise inevitably through coupling to internal degrees of freedom while amplifying the signal. The introduction of quantum correlations can effectively suppress this extra noise. In this work, we utilize the established quantum correlation between the Stokes field and atomic spin waves in the Raman amplification process to feedback a portion of the Stokes field into the amplifier. This leads to a reduction in quantum noise that is independent of the feedback loss at high gain. A maximum of 6 dB noise reduction is observed. The single-path feedback amplifier is found to be sensitive to the feedback phase, a property that expands its potential for applications in quantum precision measurement, and the general concept can be extended to integrated optics and fiber optic systems.

quant-pharXiv:2602.22567•Feb 27, 2026•1 citation
Optical interferometers, as precision measurement tools, inevitably experience optical path losses in practical applications, which introduce unavoidable vacuum noise and reduce the sensitivity in the phase estimation. To mitigate the effects of losses on sensitivity, we propose an enhanced interferometer scheme that integrates a Raman amplifier. This amplifier is strategically positioned within the lossy interference arm to counteract the reduction in phase sensitivity caused by losses. Our research highlights the crucial role of amplifier positioning, revealing that pre-amplification (PRA, placing the amplifier before the lossy section) significantly outperforms post-amplification (POA, placing the amplifier after the lossy section). PRA effectively enhances sensitivity by increasing the number of phase-sensitive particles and minimizing noise amplification. As the loss increases, the superiority of PRA in mitigating loss effects becomes increasingly evident. To validate our approach, we conducted experimental demonstrations. When the losses reach 90%, PRA experimentally achieves a sensitivity improvement of 4.6 dB compared with the case of only loss without the amplifier, equivalent to increasing the input laser power by over 8 times. PRA can effectively improve the robustness against losses for the practical application solely through the use of a coherent amplifier, with a simple technical implementation yet remarkable enhancement effects. We believe that current PRA-enhanced interferometry facilitates the practical implementation of phase measurement in environments characterized by significant loss.
Quantum interferometers offer phase measurement capabilities that surpass the standard quantum limit (SQL), with phase sensitivity and quantum enhancement factor serving as key performance metrics. However, practical implementations face severe degradation of both metrics due to unavoidable losses, representing the foremost challenge in advancing quantum interferometry toward real-world applications. To address this challenge, we propose a coherent-amplifier-empowered quantum interferometer. The coherent amplifier dramatically suppresses the decay of both sensitivity and quantum enhancement under high-loss conditions, maintaining phase sensitivity beyond the original SQL even for losses exceeding 90%. Using an injected 4.2 dB squeezed-vacuum state in experimental demonstration, our scheme reduces the quantum enhancement degradation under 90% loss from 3.7 dB in a conventional quantum interferometer (CQI) to only 1.5 dB. More importantly, the phase sensitivity degradation under the same loss is limited to 4.0 dB, markedly outperforming the 11.2 dB degradation observed in a CQI. This improvement is enabled by the coherent amplifier's phase-sensitive photon amplification and its protection of the quantum state. This breakthrough in amplifier-empowered quantum interferometry overcomes the critical barrier to practical deployment, enabling robust quantum-enhanced measurements in lossy environments.
Correlated interferometry offers various advantages in precision measurements, such as sub-shot noise sensitivity, high resolution, and prevention of detector saturation benefiting from dark output. In certain practical scenarios, e.g. absorptive measurement, there is usually unbalanced loss between the probe and reference beams, which destroys the correlation and remains a significant obstacle in the efficient application of entanglements. Here, we study the performance of a nonlinear interferometer whose arms experience unbalanced loss and demonstrate the use of a phase-sensitive amplifier in the sensing or reference arms to amplify or squeeze the light field, which can both reduce the degradation of quantum enhancement from unbalanced absorption in a lossy environment. We find that the loss after amplification, i.e. from imperfect interferometry and detection, can be mitigated when the phase-sensitive amplifier is placed at the sensing arm and functions as a noiseless amplifier. Our approach may be helpful to the practical application of quantum-enhanced absorptive measurement.
The sensitivity of future gravitational wave interferometers is expected to be limited throughout the detection band by quantum vacuum fluctuations, which can be reduced by applying quantum optics techniques such as squeezed vacuum injection. However, decoherence caused by optical losses in the readout chain will severely limit the effectiveness of such schemes. It was proposed that effect of losses in the final stage of detection can be mitigated by a phase-sensitive amplifier placed in between the output port of the interferometer and the photodetector. In this paper we propose to implement such amplification using an optomechanical device, study some of its practical limitations, and discuss its applicability to next-generation gravitational-wave detectors.
In the optical sensing context one of the main challenge is to design and implement novel techniques of sensing optimized to work in a lossy scenario, in which effects of environmental disturbances can destroy the benefits deriving from the adoption of quantum resources. Here we describe the experimental implementation of a protocol based on the process of optical parametric amplification to boost interferometry sensitivity in the presence of losses in a minimally invasive scenario. By performing the amplification process on a microscopic probe after the interaction with the sample, we can beat the losses detrimental effect on the phase measurement which affects the single photon state after its interaction with the sample, and thus improve the achievable sensitivity.
A nonlinear interferometer uses nonlinear elements as beam splitters to split and to recombine optical waves for interference. As a result, the interference fringe size has a nonlinear dependence on the intensity of the field for phase sensing and leads to an enhanced phase signal. In this paper, a practical scheme of nonlinear interferometry for precision phase measurement is analyzed with parametric amplifiers as the nonlinear beam splitters. It is found that the signal due to phase shift is enhanced by a factor of the amplification gain as compared to a linear interferometer with the same phase-sensing light intensity while the quantum noise is kept at the vacuum level, thus, effectively increasing the signal-to-noise ratio (SNR) beyond the standard quantum limit. Furthermore, the scheme is not as sensitive to the detection loss as the linear scheme with a squeezed state for noise reduction. However, losses inside the interferometer limit the enhancement factor in SNR. We apply the concept to a Michelson interferometer but with parametric amplifiers involved for gravitational-wave detection. We find that effective power is increased by the gain of the amplifiers without actually increasing the cycling power inside the interferometer. Furthermore, the full benefits with squeezed input and variational output or the combination of a quantum nondemolition interferometer for sensitivity beyond the standard quantum limit apply here with even better results. Such a nonlinear interferometer will find wide applications in precision measurements.
A quantum amplifier usually adds extra noise inevitably through coupling to internal degrees of freedom while amplifying the signal. The introduction of quantum correlations can effectively suppress this extra noise. In this work, we utilize the established quantum correlation between the Stokes field and atomic spin waves in the Raman amplification process to feedback a portion of the Stokes field into the amplifier. This leads to a reduction in quantum noise that is independent of the feedback loss at high gain. A maximum of 6 dB noise reduction is observed. The single-path feedback amplifier is found to be sensitive to the feedback phase, a property that expands its potential for applications in quantum precision measurement, and the general concept can be extended to integrated optics and fiber optic systems.