Results in Physics

Single-light-source three-axis atomic magnetometer based on orthogonal and non-overlapping dual-pump beams

Lin Li, Junjian Tang, Binbin Zhao, Yueyang Zhai

Published Jul 13, 2023• 7 citations
Publisher

Abstract

In this paper, we propose a three-axis atomic magnetometer (AM), in which one light beam is divided into two orthogonal spatially separated pump beams by a lateral displacement polarized beam splitter and reflector mirrors; this scheme suppresses the three-axis crosstalk caused by the interaction between the two beams and atoms in the cell. When the AM operates in the direct-current (DC) mode, the three-axis crosstalk is significant. To solve this problem, three modulation fields with the same amplitudes, frequencies, and different phases are applied, which allow the AM operated in modulation mode to perform a highly sensitive synchronous and independent measurement of the three-axis magnetic field with low crosstalk. The experimental results showed that the three-axis crosstalk was less than 2%. In the modulation mode, the sensitivities were 22, 23, and 26 fT/Hz1/2 on the x-, y-, and z-axes, respectively. The 3-dB bandwidths of the three axes were 126, 124, and 112 Hz. In addition, we demonstrated a three-axis in-situ magnetic compensation method with a magnetic compensation accuracy of the pT level in the DC mode. The proposed triaxial AM can be easily miniaturised and used in biomedical applications, such as in magnetocardiography and magnetoencephalography.

DOI
10.1016/j.rinp.2023.106728

Related papers

High-sensitivity operation of a single-beam atomic magnetometer for three-axis magnetic field measurement

Junjian Tang, Yueyang Zhai, Cao Li +6 more

We demonstrate a single-beam atomic magnetometer (AM) capable of measuring a three-axis magnetic field with high-sensitivity, achieved by applying a small DC offset field and a high frequency modulation field. To satisfy the miniaturization demand of AMs, an elliptically polarized light detuned by 50 GHz from the resonance transition center is employed. The circularly polarized component is used to polarize the alkali-metal atoms, while the linearly polarized light is used to detect the dynamics of the polarized spin under a magnetic field. Based on theoretical analysis, parameters that significantly affect the performance are optimized, and a sensitivity of 20 fT/Hz 1/2 in x -axis, 25 fT/Hz 1/2 in y -axis, 30 fT/Hz 1/2 in z -axis is achieved with a miniature 4 × 4 × 4 mm 87 Rb vapor cell. Moreover, we also verify that the operation principle of AMs can be used to null background magnetic fields in-situ with isotropic compensation resolution of 6.7 pT, which provides an effectively precise method for zeroing ambient magnetic field. The high-sensitivity operating of an elliptically-polarized-laser-based magnetometer provides prospective futures for constructing a compact, low-cost AM, which is particularly applicable for non-invasive bio-magnetic imaging such as array-based magnetoencephalography (MEG) and magnetocardiography (MCG).

Optics Express•May 3, 2021•125 citations

Pulsed-Modulation Single-Beam Three-Axis Atomic Magnetometer

Shushan Gao, Xiaoyu Li, Jianwei Sheng +5 more

The three-axis spin-exchange relaxation-free (SERF) atomic magnetometer (AM) enables full-vector magnetic field measurements with high sensitivity, offering significant potential for improving the accuracy of magnetic source reconstruction. However, most existing three-axis schemes rely on multiple continuous high-frequency modulation fields, which reintroduce spin-exchange relaxation and induce interaxis crosstalk. Here, we propose a three-axis magnetic field measurement method based on pulsed magnetic field modulation. By applying a transverse rotating pulsed field and a longitudinal pulsed field, the three-axis components of the vector magnetic field can be extracted from the longitudinal transmitted optical signal. The pulsed magnetic field reduces the continuous interaction time of the modulation field via its duty cycle, thereby suppressing spin-exchange relaxation. The designed synchronized time-division three-axis pulsed fields avoid the coupling effect of multiaxis modulation on spin polarization in the overlap region, thus effectively minimizing interaxis crosstalk while enabling real-time three-axis measurement. Experimental results demonstrate that the proposed method reduces the modulation-induced spin-exchange relaxation rate by approximately 40 %, achieving transverse dual-axis sensitivity of 13 fT/Hz${}^{\text {1/2}}$for the$x$- and$y$-axes, and a longitudinal sensitivity of 70 fT/Hz${}^{\text {1/2}}$for the$z$-axis in a$4\times 4\times 4$mm${}^{\text {3 87}}$Rb vapor cell. The interaxis crosstalk is suppressed to less than 1 % over the 1–100-Hz bandwidth. The proposed scheme provides new insights for constructing compact and low-cost single-beam three-axis SERF AMs.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2026•0 citations

Single-beam triaxial spin-exchange relaxation-free atomic magnetometer utilizing transverse modulation fields

Lin Li, Junjian Tang, Binbin Zhao +3 more

Abstract We display a single-beam triaxial spin-exchange relaxation-free (SERF) atomic magnetometer by utilizing two orthogonal transverse modulation fields perpendicular to the light. The magnetic field’s three-axis vector components can be extracted simultaneously and independently from the transmitted light by lock-in amplifiers with reference to the different demodulated frequencies. We find that the residual magnetic field is a significant factor that could affect triaxial coupling, and specially the influence of the z -axis remanence on xy -axis coupling is studied in detail. Under the optimal parameters, the three-axis sensitivities are 20 fT Hz − 1 / 2 in the x - and y - axis, and 230 fT Hz − 1 / 2 in the z -axis. Meanwhile, the three-axis bandwidths are 110 Hz, 138 Hz and 211 Hz in the x -, y - and z -axis, respectively. The proposed single-beam triaxial SERF atomic magnetometer could be used to construct a compact and low-cost atomic sensor that is particularly suitable for the vector measurement of the biomagnetic such as magnetoencephalography and magnetocardiography.

Journal of Physics D Applied Physics•Oct 24, 2022•23 citations

A high-sensitivity single-light-dource triaxial atomic magnetometer with double-cell and orthogonally pumped structure

Zinan Wu, Jialong Zhang, Mengyang He +7 more

We first report a single-light-source orthogonally pumped triaxial atomic magnetometer with a double-cell structure. By using a beam splitter to equally allocate the pump beam, the proposed triaxial atomic magnetometer is responsive to magnetic fields in all three directions, and without sacrificing system sensitivity. The experimental results indicate that, the magnetometer achieves a sensitivity of 22 fT/Hz 1/2 in x-direction with a 3-dB bandwidth of 22 Hz, a sensitivity of 23 fT/Hz 1/2 in y-direction with a 3-dB bandwidth of 23 Hz, and a sensitivity of 21 fT/Hz 1/2 in z-direction with a 3-dB bandwidth of 25 Hz. This magnetometer is useful for the applications that require the measurements of the three components of the magnetic field.

Optics Express•Feb 24, 2023•13 citations

A High-Sensitivity Single-Beam Triaxial Atomic Magnetometer Based on Optical Fiber Transmission

Zinan Wu, Jialong Zhang, Mengyang He +6 more

The SERF atomic magnetometer is nowadays the most sensitive equipment for magnetic field measurement. As used in triaxial magnetic field measurements, however, the weak interaction of the polarized atoms with the magnetic field in the pump light direction results in low sensitivity in that direction. To solve this issue, a single-beam orthogonal pumping triaxial atomic magnetometer based on a double-cell structure is demonstrated. In this paper, we use a beam-splitter to split the pumping light beam equally, so that the proposed triaxial atomic magnetometer can respond to magnetic fields in all three axes simultaneously, and with no sacrifice in sensitivity. The experiments have shown that the magnetometer has a sensitivity of 46fT/Hz1/2on the x-axis, 32fT/Hz1/2on the y-axis, and 40fT/Hz1/2on the z-axis. This magnetometer has great potential for applications where the three components of the magnetic field need to be measured.

IEEE Conference on Telecommunications, Optics and Computer Science (TOCS)•Dec 11, 2022•0 citations

Dual-Axis Measurement and Suppression Method for Light Shift Based on a Single-Beam Compact SERF Atomic Magnetometer

Kexuan Miao, Tao Hu, Yan Chang +2 more

The light shift in a spin-exchange relaxation-free (SERF) atomic magnetometer (AM) generated by detuning of circularly polarized pump light, results in deviations of orthogonality measurement and attenuation of magnetometer response. In this paper, we propose and systematically investigate a dual-axis method to suppress light shift based on a self-developed single-beam compact SERF AM capable of measuring magnetic field components along two orthogonal sensitive axes. By sequentially observing the non-sensitive axis response and applying a magnetic field along the pump light direction, the virtual magnetic field induced by light shift is compensated and is rigorously demonstrated as a dominant component in this direction. Experimental results show a significant reduction in crosstalk between the dual sensitive axes, improving accuracy in resonant frequency determination of87Rb atoms and orthogonality evaluation of triaxial coils. Furthermore, the performance of dual-axis measurement in the SERF AM is tested, showing a more notable enhancement than that of single-axis measurement.

IEEE Sensors Journal•Jan 7, 2025•3 citations
In this paper, we propose a three-axis atomic magnetometer (AM), in which one light beam is divided into two orthogonal spatially separated pump beams by a lateral displacement polarized beam splitter and reflector mirrors; this scheme suppresses the three-axis crosstalk caused by the interaction between the two beams and atoms in the cell. When the AM operates in the direct-current (DC) mode, the three-axis crosstalk is significant. To solve this problem, three modulation fields with the same amplitudes, frequencies, and different phases are applied, which allow the AM operated in modulation mode to perform a highly sensitive synchronous and independent measurement of the three-axis magnetic field with low crosstalk. The experimental results showed that the three-axis crosstalk was less than 2%. In the modulation mode, the sensitivities were 22, 23, and 26 fT/Hz1/2 on the x-, y-, and z-axes, respectively. The 3-dB bandwidths of the three axes were 126, 124, and 112 Hz. In addition, we demonstrated a three-axis in-situ magnetic compensation method with a magnetic compensation accuracy of the pT level in the DC mode. The proposed triaxial AM can be easily miniaturised and used in biomedical applications, such as in magnetocardiography and magnetoencephalography.
We demonstrate a single-beam atomic magnetometer (AM) capable of measuring a three-axis magnetic field with high-sensitivity, achieved by applying a small DC offset field and a high frequency modulation field. To satisfy the miniaturization demand of AMs, an elliptically polarized light detuned by 50 GHz from the resonance transition center is employed. The circularly polarized component is used to polarize the alkali-metal atoms, while the linearly polarized light is used to detect the dynamics of the polarized spin under a magnetic field. Based on theoretical analysis, parameters that significantly affect the performance are optimized, and a sensitivity of 20 fT/Hz 1/2 in x -axis, 25 fT/Hz 1/2 in y -axis, 30 fT/Hz 1/2 in z -axis is achieved with a miniature 4 × 4 × 4 mm 87 Rb vapor cell. Moreover, we also verify that the operation principle of AMs can be used to null background magnetic fields in-situ with isotropic compensation resolution of 6.7 pT, which provides an effectively precise method for zeroing ambient magnetic field. The high-sensitivity operating of an elliptically-polarized-laser-based magnetometer provides prospective futures for constructing a compact, low-cost AM, which is particularly applicable for non-invasive bio-magnetic imaging such as array-based magnetoencephalography (MEG) and magnetocardiography (MCG).
The three-axis spin-exchange relaxation-free (SERF) atomic magnetometer (AM) enables full-vector magnetic field measurements with high sensitivity, offering significant potential for improving the accuracy of magnetic source reconstruction. However, most existing three-axis schemes rely on multiple continuous high-frequency modulation fields, which reintroduce spin-exchange relaxation and induce interaxis crosstalk. Here, we propose a three-axis magnetic field measurement method based on pulsed magnetic field modulation. By applying a transverse rotating pulsed field and a longitudinal pulsed field, the three-axis components of the vector magnetic field can be extracted from the longitudinal transmitted optical signal. The pulsed magnetic field reduces the continuous interaction time of the modulation field via its duty cycle, thereby suppressing spin-exchange relaxation. The designed synchronized time-division three-axis pulsed fields avoid the coupling effect of multiaxis modulation on spin polarization in the overlap region, thus effectively minimizing interaxis crosstalk while enabling real-time three-axis measurement. Experimental results demonstrate that the proposed method reduces the modulation-induced spin-exchange relaxation rate by approximately 40 %, achieving transverse dual-axis sensitivity of 13 fT/Hz1/2{}^{\text {1/2}}1/2for thexxx- andyyy-axes, and a longitudinal sensitivity of 70 fT/Hz1/2{}^{\text {1/2}}1/2for thezzz-axis in a4×4×44\times 4\times 44×4×4mm3 87{}^{\text {3 87}}3 87Rb vapor cell. The interaxis crosstalk is suppressed to less than 1 % over the 1–100-Hz bandwidth. The proposed scheme provides new insights for constructing compact and low-cost single-beam three-axis SERF AMs.
Abstract We display a single-beam triaxial spin-exchange relaxation-free (SERF) atomic magnetometer by utilizing two orthogonal transverse modulation fields perpendicular to the light. The magnetic field’s three-axis vector components can be extracted simultaneously and independently from the transmitted light by lock-in amplifiers with reference to the different demodulated frequencies. We find that the residual magnetic field is a significant factor that could affect triaxial coupling, and specially the influence of the z -axis remanence on xy -axis coupling is studied in detail. Under the optimal parameters, the three-axis sensitivities are 20 fT Hz − 1 / 2 in the x - and y - axis, and 230 fT Hz − 1 / 2 in the z -axis. Meanwhile, the three-axis bandwidths are 110 Hz, 138 Hz and 211 Hz in the x -, y - and z -axis, respectively. The proposed single-beam triaxial SERF atomic magnetometer could be used to construct a compact and low-cost atomic sensor that is particularly suitable for the vector measurement of the biomagnetic such as magnetoencephalography and magnetocardiography.
We first report a single-light-source orthogonally pumped triaxial atomic magnetometer with a double-cell structure. By using a beam splitter to equally allocate the pump beam, the proposed triaxial atomic magnetometer is responsive to magnetic fields in all three directions, and without sacrificing system sensitivity. The experimental results indicate that, the magnetometer achieves a sensitivity of 22 fT/Hz 1/2 in x-direction with a 3-dB bandwidth of 22 Hz, a sensitivity of 23 fT/Hz 1/2 in y-direction with a 3-dB bandwidth of 23 Hz, and a sensitivity of 21 fT/Hz 1/2 in z-direction with a 3-dB bandwidth of 25 Hz. This magnetometer is useful for the applications that require the measurements of the three components of the magnetic field.
The SERF atomic magnetometer is nowadays the most sensitive equipment for magnetic field measurement. As used in triaxial magnetic field measurements, however, the weak interaction of the polarized atoms with the magnetic field in the pump light direction results in low sensitivity in that direction. To solve this issue, a single-beam orthogonal pumping triaxial atomic magnetometer based on a double-cell structure is demonstrated. In this paper, we use a beam-splitter to split the pumping light beam equally, so that the proposed triaxial atomic magnetometer can respond to magnetic fields in all three axes simultaneously, and with no sacrifice in sensitivity. The experiments have shown that the magnetometer has a sensitivity of 46fT/Hz1/2on the x-axis, 32fT/Hz1/2on the y-axis, and 40fT/Hz1/2on the z-axis. This magnetometer has great potential for applications where the three components of the magnetic field need to be measured.
The light shift in a spin-exchange relaxation-free (SERF) atomic magnetometer (AM) generated by detuning of circularly polarized pump light, results in deviations of orthogonality measurement and attenuation of magnetometer response. In this paper, we propose and systematically investigate a dual-axis method to suppress light shift based on a self-developed single-beam compact SERF AM capable of measuring magnetic field components along two orthogonal sensitive axes. By sequentially observing the non-sensitive axis response and applying a magnetic field along the pump light direction, the virtual magnetic field induced by light shift is compensated and is rigorously demonstrated as a dominant component in this direction. Experimental results show a significant reduction in crosstalk between the dual sensitive axes, improving accuracy in resonant frequency determination of87Rb atoms and orthogonality evaluation of triaxial coils. Furthermore, the performance of dual-axis measurement in the SERF AM is tested, showing a more notable enhancement than that of single-axis measurement.