Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Express

Pulsed-CPT Cs-Ne microcell atomic clock with frequency stability below 2 × 10 −12 at 10 5 s

Clément Carlé, Moustafa Abdel Hafiz, Shervin Keshavarzi, Rémy Vicarini, Nicolas Passilly, Rodolphe Boudot

Published Feb 10, 2023• 31 citations
Publisher

Abstract

We report on the mid-term stability progress of a table-top coherent population trapping (CPT) microcell atomic clock, previously limited by light-shift effects and variations of the cell's inner atmosphere. The light-shift contribution is now mitigated through the use of a pulsed symmetric auto-balanced Ramsey (SABR) interrogation technique, combined with setup temperature, laser power, and microwave power stabilization. In addition, Ne buffer gas pressure variations in the cell are now greatly reduced through the use of a micro-fabricated cell built with low permeation alumino-silicate glass (ASG) windows. Combining these approaches, the clock Allan deviation is measured to be 1.4 × 10 −12 at 10 5 s. This stability level at one day is competitive with the best current microwave microcell-based atomic clocks.

DOI
10.1364/oe.483039

Related papers

Symmetric autobalanced Ramsey interrogation for high-performance coherent-population-trapping vapor-cell atomic clock

Moustafa Abdel Hafiz, Grégoire Coget, M. Petersen +4 more

We report a high-performance pulsed coherent population trapping (CPT) Cs cell atomic clock using the implementation of a symmetric auto-balanced Ramsey (SABR) interrogation sequence. The latter method is found to reduce the light-power induced frequency shift by an order of magnitude compared to a previous experiment using a simple auto-balanced Ramsey interrogation. The contribution of this shift to the clock frequency stability is now rejected in the 10−16 range at 104 s averaging time. Additional tricks, including a compensation method to reduce the laser amplitude noise contribution and the generation of novel error signals for local oscillator frequency and phase correction, have been implemented using a FPGA-based digital electronics board in order to improve the clock short-term stability by a of factor 2. The Allan deviation of the SABR-CPT clock, extracted from a selected 3 × 104 s-long dataset, is 2 × 10−13 τ−1∕2 and averages down to the level of 2.5 × 10−15 at 104 s. These results are encouraging to stimulate the development of hot cell CPT-based clocks for industrial, scientific, and instrumentation applications.

Applied Physics Letters•Jun 11, 2018•78 citations

Microcell atomic clock using laser current-actuated power modulation with 10−12 range stability at 1 day

C. M. Rivera-Aguilar, Andrei Mursa, Clément Carlé +5 more

We present a coherent-population trapping (CPT) microcell atomic clock using symmetric auto-balanced Ramsey (SABR) spectroscopy. The pulsed SABR sequence is applied through direct current-based power modulation of the vertical-cavity surface-emitting laser, eliminating the need for an external optical shutter and enabling compatibility with fully-integrated clocks. The sequence is controlled by a single FPGA-based digital electronics board. A key aspect of proper clock operation was the implementation of a real-time tracking of the atomic signal detection window. The clock frequency dependence on laser power, microwave power, laser frequency, and timing of the detection window has been measured, obtaining sensitivity coefficients lower than those obtained with Ramsey-CPT spectroscopy. The Allan deviation of the SABR-CPT clock, based on a microfabricated cell with low-permeation glass windows, is 8 × 10 −10 at 1 s and averages down in the 10 −12 range at 1 day. These results might stimulate the development of chip-scale atomic clocks using Ramsey-based sequences, with reduced light-shift sensitivity, and enhanced long-term stability performances.

arXiv:2503.01681•Scientific Reports•Oct 15, 2025•1 citation

Light-shift mitigation in a microcell-based atomic clock with symmetric auto-balanced Ramsey spectroscopy

Moustafa Abdel Hafiz, Clément Carlé, Nicolas Passilly +3 more

The mid-term fractional frequency stability of miniaturized atomic clocks can be limited by light-shift effects. In this Letter, we demonstrate the implementation of a symmetric auto-balanced Ramsey (SABR) interrogation sequence in a microcell-based atomic clock based on coherent population trapping. Using this advanced protocol, the sensitivity of the clock frequency to laser power, microwave power, and laser frequency variations is reduced, at least by one order of magnitude, in comparison with continuous-wave or Ramsey interrogation schemes. Light-shift mitigation obtained with the SABR sequence benefits greatly to the clock Allan deviation for integration times between 102 and 105 s. These results demonstrate that such interrogation techniques are of interest to enhance the timekeeping performance of chip-scale atomic clocks.

arXiv:2112.07492•Applied Physics Letters•Feb 7, 2022•19 citations

Exploring Ramsey-CPT spectroscopy in a microcell atomic clock

Clément Carlé, Petersen, Michael, Nicolas Passilly +2 more

Chip-scale atomic clocks (CSACs) based on coherent population trapping (CPT) have attracted significant research and development efforts due to their unrivaled size-power-stability budget [1]. In such clocks, the continuous-wave (CW) interaction of atoms with light yields power broadening and a significant sensitivity of the clock frequency to light-shift effects that contribute to the clock mid-term and long-term stability budget. Numerous approaches have been demonstrated in the literature to reduce light-shift effects in CW-CPT clocks [2-6]. In this study, using an external acousto-optic modulator to produce the interrogation sequence, we investigate the use of Ramsey-CPT spectroscopy in a buffer-gas filled microcell atomic clock. Some results are compared with those obtained in the standard CW regime. In the Ramsey-CPT case, the clock frequency dependence to laser power is reduced by a factor of 60 with a dark time T of 450 µs, at the expense of a 3 times higher operation power. The sensitivity to microwave power variations is reduced by a factor higher than 2. The Ramsey-CPT interrogation improves the clock Allan deviation for time scales in the 100-10 4 s range, at the expense of a degraded short-term stability when the dark time T is increased too much. A clock frequency stability of 3.8 × 10 −12 at 10 4 s is obtained with T = 450 µs, in comparison with the level of 8 × 10 −11 obtained in the standard CW case, in similar experimental conditions and the same cell. These results suggest that Ramsey-based interrogation protocols might be an attractive approach for the development of CSACs with enhanced mid-and long-term stability.

•Mar 22, 2021•0 citations

Ramsey-CPT spectroscopy for a microcell atomic clock

Clément Carlé, Petersen, Michael, Nicolas Passilly +3 more

We investigate the use of pulsed Ramsey-CPT spectroscopy in a coherent population trapping (CPT) atomic clock using a microfabricated buffer gas-filled Cs vapor cell. Tests are performed on a table-top setup with an external acousto-optical modulator (AOM) to produce the optical CPT pulse sequence. A relevant reduction of the clock frequency sensitivity to laser power variations by a factor of about 40 is observed, in comparison with the standard continuous-wave (CW) regime, with a free-evolution time T = 450 μs. The dependence to microwave power variations is also reduced in the Ramsey-CPT interrogation case. With the same cell physics package and similar environmental conditions, the clock Allan deviation is clearly improved for time scales higher than 100 s in the Ramsey-CPT case. These results suggest that the use of Ramsey spectroscopy might be an attractive approach in miniature clocks

•Jul 7, 2021•0 citations

Exploring the Use of Ramsey-CPT Spectroscopy for a Microcell-Based Atomic Clock

Clément Carlé, Michael Petersen, Nicolas Passilly +3 more

We investigate the application of Ramsey spectroscopy for the development of a microcell atomic clock based on coherent population trapping (CPT). The dependence of the central Ramsey-CPT fringe properties on key experimental parameters is first studied for optimization of the clock’s short-term frequency stability. The sensitivity of the clock frequency to light-shift effects is then studied. In comparison with the continuous-wave (CW) regime case, the sensitivity of the clock frequency to laser power variations is reduced by a factor up to 14 and 40.3 for dark times of 150 and$450~\mu \text{s}$, respectively, at the expense of intensity 3.75 times higher for short-term stability optimization. The dependence of the clock frequency on the microwave power is also reduced in the Ramsey case. We demonstrate that the Ramsey-CPT interrogation improves the clock Allan deviation for averaging times higher than 100 s. With a dark time of$450~\mu \text{s}$, a clock fractional frequency stability of$3.8 \times 10^{-12}$at 104s is obtained, in comparison with the level of$8\times 10^{-11}$obtained in the standard CW case, in similar environmental conditions. These results demonstrate that Ramsey-based interrogation protocols might be an attractive approach for the development of chip-scale atomic clocks (CSACs) with enhanced mid- and long-term stability.

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control•Jun 2, 2021•18 citations
We report on the mid-term stability progress of a table-top coherent population trapping (CPT) microcell atomic clock, previously limited by light-shift effects and variations of the cell's inner atmosphere. The light-shift contribution is now mitigated through the use of a pulsed symmetric auto-balanced Ramsey (SABR) interrogation technique, combined with setup temperature, laser power, and microwave power stabilization. In addition, Ne buffer gas pressure variations in the cell are now greatly reduced through the use of a micro-fabricated cell built with low permeation alumino-silicate glass (ASG) windows. Combining these approaches, the clock Allan deviation is measured to be 1.4 × 10 −12 at 10 5 s. This stability level at one day is competitive with the best current microwave microcell-based atomic clocks.
We report a high-performance pulsed coherent population trapping (CPT) Cs cell atomic clock using the implementation of a symmetric auto-balanced Ramsey (SABR) interrogation sequence. The latter method is found to reduce the light-power induced frequency shift by an order of magnitude compared to a previous experiment using a simple auto-balanced Ramsey interrogation. The contribution of this shift to the clock frequency stability is now rejected in the 10−16 range at 104 s averaging time. Additional tricks, including a compensation method to reduce the laser amplitude noise contribution and the generation of novel error signals for local oscillator frequency and phase correction, have been implemented using a FPGA-based digital electronics board in order to improve the clock short-term stability by a of factor 2. The Allan deviation of the SABR-CPT clock, extracted from a selected 3 × 104 s-long dataset, is 2 × 10−13 τ−1∕2 and averages down to the level of 2.5 × 10−15 at 104 s. These results are encouraging to stimulate the development of hot cell CPT-based clocks for industrial, scientific, and instrumentation applications.
We present a coherent-population trapping (CPT) microcell atomic clock using symmetric auto-balanced Ramsey (SABR) spectroscopy. The pulsed SABR sequence is applied through direct current-based power modulation of the vertical-cavity surface-emitting laser, eliminating the need for an external optical shutter and enabling compatibility with fully-integrated clocks. The sequence is controlled by a single FPGA-based digital electronics board. A key aspect of proper clock operation was the implementation of a real-time tracking of the atomic signal detection window. The clock frequency dependence on laser power, microwave power, laser frequency, and timing of the detection window has been measured, obtaining sensitivity coefficients lower than those obtained with Ramsey-CPT spectroscopy. The Allan deviation of the SABR-CPT clock, based on a microfabricated cell with low-permeation glass windows, is 8 × 10 −10 at 1 s and averages down in the 10 −12 range at 1 day. These results might stimulate the development of chip-scale atomic clocks using Ramsey-based sequences, with reduced light-shift sensitivity, and enhanced long-term stability performances.
The mid-term fractional frequency stability of miniaturized atomic clocks can be limited by light-shift effects. In this Letter, we demonstrate the implementation of a symmetric auto-balanced Ramsey (SABR) interrogation sequence in a microcell-based atomic clock based on coherent population trapping. Using this advanced protocol, the sensitivity of the clock frequency to laser power, microwave power, and laser frequency variations is reduced, at least by one order of magnitude, in comparison with continuous-wave or Ramsey interrogation schemes. Light-shift mitigation obtained with the SABR sequence benefits greatly to the clock Allan deviation for integration times between 102 and 105 s. These results demonstrate that such interrogation techniques are of interest to enhance the timekeeping performance of chip-scale atomic clocks.
Chip-scale atomic clocks (CSACs) based on coherent population trapping (CPT) have attracted significant research and development efforts due to their unrivaled size-power-stability budget [1]. In such clocks, the continuous-wave (CW) interaction of atoms with light yields power broadening and a significant sensitivity of the clock frequency to light-shift effects that contribute to the clock mid-term and long-term stability budget. Numerous approaches have been demonstrated in the literature to reduce light-shift effects in CW-CPT clocks [2-6]. In this study, using an external acousto-optic modulator to produce the interrogation sequence, we investigate the use of Ramsey-CPT spectroscopy in a buffer-gas filled microcell atomic clock. Some results are compared with those obtained in the standard CW regime. In the Ramsey-CPT case, the clock frequency dependence to laser power is reduced by a factor of 60 with a dark time T of 450 µs, at the expense of a 3 times higher operation power. The sensitivity to microwave power variations is reduced by a factor higher than 2. The Ramsey-CPT interrogation improves the clock Allan deviation for time scales in the 100-10 4 s range, at the expense of a degraded short-term stability when the dark time T is increased too much. A clock frequency stability of 3.8 × 10 −12 at 10 4 s is obtained with T = 450 µs, in comparison with the level of 8 × 10 −11 obtained in the standard CW case, in similar experimental conditions and the same cell. These results suggest that Ramsey-based interrogation protocols might be an attractive approach for the development of CSACs with enhanced mid-and long-term stability.
We investigate the use of pulsed Ramsey-CPT spectroscopy in a coherent population trapping (CPT) atomic clock using a microfabricated buffer gas-filled Cs vapor cell. Tests are performed on a table-top setup with an external acousto-optical modulator (AOM) to produce the optical CPT pulse sequence. A relevant reduction of the clock frequency sensitivity to laser power variations by a factor of about 40 is observed, in comparison with the standard continuous-wave (CW) regime, with a free-evolution time T = 450 μs. The dependence to microwave power variations is also reduced in the Ramsey-CPT interrogation case. With the same cell physics package and similar environmental conditions, the clock Allan deviation is clearly improved for time scales higher than 100 s in the Ramsey-CPT case. These results suggest that the use of Ramsey spectroscopy might be an attractive approach in miniature clocks
We investigate the application of Ramsey spectroscopy for the development of a microcell atomic clock based on coherent population trapping (CPT). The dependence of the central Ramsey-CPT fringe properties on key experimental parameters is first studied for optimization of the clock’s short-term frequency stability. The sensitivity of the clock frequency to light-shift effects is then studied. In comparison with the continuous-wave (CW) regime case, the sensitivity of the clock frequency to laser power variations is reduced by a factor up to 14 and 40.3 for dark times of 150 and450 μs450~\mu \text{s}450 μs, respectively, at the expense of intensity 3.75 times higher for short-term stability optimization. The dependence of the clock frequency on the microwave power is also reduced in the Ramsey case. We demonstrate that the Ramsey-CPT interrogation improves the clock Allan deviation for averaging times higher than 100 s. With a dark time of450 μs450~\mu \text{s}450 μs, a clock fractional frequency stability of3.8×10−123.8 \times 10^{-12}3.8×10−12at 104s is obtained, in comparison with the level of8×10−118\times 10^{-11}8×10−11obtained in the standard CW case, in similar environmental conditions. These results demonstrate that Ramsey-based interrogation protocols might be an attractive approach for the development of chip-scale atomic clocks (CSACs) with enhanced mid- and long-term stability.