Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

High-sensitivity cold-atom gyroscope with real-time vibration compensation

Matteo Altorio, Denis Savoie, Bess Fang, Rémi Geiger, Arnaud Landragin

Published Sep 26, 2017• 0 citations
OpenAlex

Abstract

Our cold-atom gyroscope is based on a four-pulse configuration with a very large Sagnac area. Its short-term stability is limited by aliasing effects of the inertial forces (acceleration and rotation). We will show how continuous measurements and real-time compensation of the vibration during the interferometer sequence overcome this limit.

Related papers

High-sensitivity cold-atom gyroscope with real-time vibration compensation

Denis Savoie, Matteo Altorio, Bess Fang +2 more

Our cold-atom gyroscope is based on a four-pulse configuration with a very large Sagnac area. Its short-term stability is limited by aliasing effects of the inertial forces (acceleration and rotation). We will show how continuous measurements and real-time compensation of the vibration during the interferometer sequence overcome this limit.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 1, 2017•0 citations

High-performance gyroscope for rotational seismology.

Nathan Marliere, Mohamed Guessoum, Rémi Geiger +1 more

The Sagnac effect is at the heart of the modern precision inertial sensors. An interferometer with a physical area, when spun, exhibits a phase shift atits output. Measuring this phase-shift leads to a direct measurement of the rotation rate.The SYRTE dual-axis cold-atom gyroscope represents the state-of-art of atomic gyroscopes. With its large physical area (11cm2) and a long interrogation time of 800 ms, it offers both the sensitivity and stability 3 × 10^10 rad.s−1 to push the Sagnac measurement to an unprecedented accuracy level. Demonstrating such performance required the control and characterization of the experimental parameters and systematic effects and the precise knowledge of the scale factor. The cold-atom gyroscope experiment is based on atomic interferometry, where cooled Cesium-atoms (2μK) are launched vertically (∼ 5m/s) to be interrogated with a sequence of four Raman pulses (allowing an internal and external control over atomic states). The pulses play the role of atomic optics by splitting and guiding the matter-waves along the arms of the interferometer. By the end, transition probability measurement gives access to the phase-shift induced by rotation.I will present our recent work done to develop new methods that will improve the gyroscope sensitivity. The Double diffraction, atom diffraction inboth ±¯h⃗keff directions, should enables a measurement setup with no dead time based on the use of two correlated interleaved interferometers. Thus, the vibration and rotation noises that limits the sensitivity should average to achieve the detection noise, targeting the standard quantum projection noise.

•Sep 5, 2023•0 citations

Limits on the sensitivity of a cold atom interferometry gyroscope

Wenjie Xu, Lele Chen, Ming-Jie Nie +2 more

We present a precision atom interferometry gyroscope with a Sagnac area of 6.0 cm 2 . To drive the cold atom interferometry gyroscope, we utilize two sets of Raman beams with a pulse sequence of π /2- π - π - π /2. We present a procedure for aligning the two sets of Raman beams at the microradian level by making use of the atom interferometer itself in different configurations. Additionally, we measured the atomic cloud trajectory and implemented a spatial symmetry alignment for the atom interferometer. With these improvements, we construct a sensitive atom gyroscope with a stability of 1 nrad/s at an integration time of 10000 s. We analyzed the influence of Raman beams and the limitations of the system, and present the technical limits to the sensitivity and long-term stability. Finally, we point out the primary sources of noise in the atom interferometry gyroscope, clearing the way for the construction of further large-area atom gyroscopes.

Optics Express•Oct 28, 2024•7 citations

Characterization and limits of a cold-atom Sagnac interferometer

A. Gauguet, B. Canuel, Thomas Lévèque +2 more

We present the full evaluation of a cold-atom gyroscope based on atom interferometry. We have performed extensive studies to determine the systematic errors, scale factor and sensitivity. We demonstrate that the acceleration noise can be efficiently removed from the rotation signal, allowing us to reach the fundamental limit of the quantum projection noise for short term measurements. The technical limits to the long term sensitivity and accuracy have been identified, clearing the way for the next generation of ultrasensitive atom gyroscopes.

arXiv:0907.2580•Physical Review A•Dec 1, 2009•220 citations

Continuous cold atom inertial sensor with 1 nrad.s^-1 rotation stability (Conference Presentation)

Rémi Geiger, Indranil Dutta, Denis Savoie +4 more

We report the first operation of a cold atom inertial sensor without dead time. Dead times in conventional cold atom interferometers originate from the preparation of a cold atom source prior to its injection in the interferometer and where information on inertial signals is lost. We use a sequence where we simultaneously prepare a cold atom source and operate a light pulse atom interferometer to circumvent the dead time limitation. Therefore the sensor continuously captures all the dynamics with respect to an inertial frame. We show that the continuous operation does not degrade the sensitivity and stability of the atom interferometer, by demonstrating a rotation sensitivity level of less than 1 nrad/s after 10 000 s of integration time. Such a sensitivity level improves previous results by more than an order of magnitude and opens applications of cold atom gyroscopes in inertial navigation and geophysics.

•Aug 3, 2016•1 citation

Rotation rate measurements with a large area cold atom interferometer

Arnaud Landragin, Matteo Altorio, Romain Gautier +2 more

We present a cold atom gyroscope based on the Sagnac effect for matter-wave with very large area of 11 cm2 with record sensitivity and preliminary study of the scaling factor.

Conference on Lasers and Electro-Optics•Jan 1, 2020•0 citations
Our cold-atom gyroscope is based on a four-pulse configuration with a very large Sagnac area. Its short-term stability is limited by aliasing effects of the inertial forces (acceleration and rotation). We will show how continuous measurements and real-time compensation of the vibration during the interferometer sequence overcome this limit.
The Sagnac effect is at the heart of the modern precision inertial sensors. An interferometer with a physical area, when spun, exhibits a phase shift atits output. Measuring this phase-shift leads to a direct measurement of the rotation rate.The SYRTE dual-axis cold-atom gyroscope represents the state-of-art of atomic gyroscopes. With its large physical area (11cm2) and a long interrogation time of 800 ms, it offers both the sensitivity and stability 3 × 10^10 rad.s−1 to push the Sagnac measurement to an unprecedented accuracy level. Demonstrating such performance required the control and characterization of the experimental parameters and systematic effects and the precise knowledge of the scale factor. The cold-atom gyroscope experiment is based on atomic interferometry, where cooled Cesium-atoms (2μK) are launched vertically (∼ 5m/s) to be interrogated with a sequence of four Raman pulses (allowing an internal and external control over atomic states). The pulses play the role of atomic optics by splitting and guiding the matter-waves along the arms of the interferometer. By the end, transition probability measurement gives access to the phase-shift induced by rotation.I will present our recent work done to develop new methods that will improve the gyroscope sensitivity. The Double diffraction, atom diffraction inboth ±¯h⃗keff directions, should enables a measurement setup with no dead time based on the use of two correlated interleaved interferometers. Thus, the vibration and rotation noises that limits the sensitivity should average to achieve the detection noise, targeting the standard quantum projection noise.
We present a precision atom interferometry gyroscope with a Sagnac area of 6.0 cm 2 . To drive the cold atom interferometry gyroscope, we utilize two sets of Raman beams with a pulse sequence of π /2- π - π - π /2. We present a procedure for aligning the two sets of Raman beams at the microradian level by making use of the atom interferometer itself in different configurations. Additionally, we measured the atomic cloud trajectory and implemented a spatial symmetry alignment for the atom interferometer. With these improvements, we construct a sensitive atom gyroscope with a stability of 1 nrad/s at an integration time of 10000 s. We analyzed the influence of Raman beams and the limitations of the system, and present the technical limits to the sensitivity and long-term stability. Finally, we point out the primary sources of noise in the atom interferometry gyroscope, clearing the way for the construction of further large-area atom gyroscopes.
We present the full evaluation of a cold-atom gyroscope based on atom interferometry. We have performed extensive studies to determine the systematic errors, scale factor and sensitivity. We demonstrate that the acceleration noise can be efficiently removed from the rotation signal, allowing us to reach the fundamental limit of the quantum projection noise for short term measurements. The technical limits to the long term sensitivity and accuracy have been identified, clearing the way for the next generation of ultrasensitive atom gyroscopes.
We report the first operation of a cold atom inertial sensor without dead time. Dead times in conventional cold atom interferometers originate from the preparation of a cold atom source prior to its injection in the interferometer and where information on inertial signals is lost. We use a sequence where we simultaneously prepare a cold atom source and operate a light pulse atom interferometer to circumvent the dead time limitation. Therefore the sensor continuously captures all the dynamics with respect to an inertial frame. We show that the continuous operation does not degrade the sensitivity and stability of the atom interferometer, by demonstrating a rotation sensitivity level of less than 1 nrad/s after 10 000 s of integration time. Such a sensitivity level improves previous results by more than an order of magnitude and opens applications of cold atom gyroscopes in inertial navigation and geophysics.