Optics Letters

Frequency shift caused by a magnetic field and light intensity inhomogeneity in an optically detected clock

Yuanhao Li, Chen Liu, Sifei Chen, Lifeng Fan, Hangzhe Lyu, Chen Feng, Jian Duan, Yanhui Wang

Published Oct 21, 2024• 0 citations
Publisher

Abstract

We present a novel, to the best of our knowledge, frequency shift mechanism in the optically detected atomic clock. This frequency shift is analogous to the light shift that is associated with a detecting light power. However, this shift arises from the inhomogeneity of the magnetic field (C-field) and the detecting light intensity. We call this shift the "pseudo-light shift" (p-LS). This shift allows the correlation between the clock output frequency and the detecting light power to switch between positive and negative, depending on the magnetic field. The mechanism is described and experimentally validated in our cesium beam clock through two experiments. The study of this frequency shift can enhance the accuracy of light shift assessments in atom-laser interaction systems and suppress long-term stability deterioration caused by the light power fluctuation.

DOI
10.1364/ol.538126

Related papers

Light shift suppression with pulsed light detection in magnetic-state-selected cesium beam clocks

Yuanhao Li, Shaohang Xu, Sifei Chen +3 more

Light detection is widely used in atomic clocks. The simple detecting structure induces the light shift which influences the clock's long-term stability. We introduce a new method to suppress light shift by using pulsed light instead of continuous light to detect atomic states. Under a suitable pulsed sequence, the part of the atoms which do not simultaneously interact with light and microwave field are detected. We demonstrate the validity of our approach in a magnetic-state-selected cesium beam clock. Using a well-tuned sequence, the light shift coefficient is reduced by a factor of about 10, in comparison with the continuous light detection scheme. In a clock stability test with extra light power noise, the result shows good immunity of the method to laser power fluctuations. We also analyze the sources of the clock short-term stability degradation, including the Dick effect and the fact that a reduced number of atoms is detected in the pulsed detection case.

Optics Express•Oct 26, 2022•6 citations

Optical frequency dependence of the light shift effect for vector magnetometry with cesium

Janet W. Lou, Geoffrey A. Cranch

Atomic vapor magnetometers have demonstrated very high sensitivity to the magnitude of the magnetic field. Vector field measurements are possible using bias fields applied to the vapor. For remote operation, the bias field can be generated using the optical light shift (LS) effect created with an optical beam delivered through optical fiber. Here, it is shown that the optical frequency of the LS effect for an optically pumped vapor vector magnetometer causes an angular error in the measured field orientation when it is tuned near the absorption resonances, countering the benefit of higher response. This angle-shifting effect is dependent on the LS beam power. The LS response, normalized to the LS power, is higher for lower powers due to a saturation effect but also shows a dependence on the LS optical frequency. We show that it is necessary to carefully choose the LS optical frequency and power to maximize the LS effect while avoiding potential angular error.

Applied Optics•Jan 28, 2020•2 citations

General Methods for Suppressing the Light Shift in Atomic Clocks Using Power Modulation

Valeriy I. Yudin, M. Yu. Basalaev, А. В. Тайченачев +8 more

We show that the light shift in atomic clocks can be suppressed using time variation of the interrogation field intensity. By measuring the clock output at two intensity levels, error signals can be generated that simultaneously stabilize a local oscillator to an atomic transition and correct for the shift of this transition caused by the interrogating optical field. These methods are suitable for optical clocks using one- and two-photon transitions, as well as for microwave clocks based on coherent population trapping or direct interrogation. The proposed methods can be widely used both for high-precision scientific instruments and for a wide range of commercial clocks, including chip-scale atomic clocks.

arXiv:1911.02935•Physical Review Applied•Aug 3, 2020•43 citations

Optical lattice polarization effects on magnetically induced optical atomic clock transitions

А. В. Тайченачев, Valeriy I. Yudin, Chris W. Oates

We derive the frequency shift for a forbidden optical transition $J=0\ensuremath{\rightarrow}{J}^{\ensuremath{'}}=0$ caused by the simultaneous actions of an elliptically polarized lattice field and a static magnetic field. We find that a simple configuration of lattice and magnetic fields leads to a cancellation of this shift to first order in lattice intensity and magnetic field. In this geometry, the second-order lattice intensity shift can be minimized as well by use of optimal lattice polarization. Suppression of these shifts could considerably enhance the performance of the next generation of atomic clocks.

Physical Review A•Aug 10, 2007•7 citations

A frequency shift compensation method for light shift and vapor-cell temperature shift in atomic clocks

Dou Li, Kangqi Liu, Linzhen Zhao +1 more

Light shift and vapor-cell temperature shift are the two most significant factors dominating the long-term instability of compact atomic clocks. Due to the different physical mechanisms, there is not yet a solution that can effectively suppress the frequency shifts induced by these two effects. Here, we propose a 'resonance-offset' locking approach that compensates for the two physical frequency shifts. In this approach, the additional offset locking shift can effectively counteract the atomic resonance shifts arising from changes in vapor-cell temperature and light power, reducing the net impact on the clock's frequency to nearly zero. We have demonstrated this strategy on the 778 nm Rubidium two-photon optical frequency standard, successfully compensating for light shift and cell-temperature shift, respectively. This general method is particularly appealing for compact vapor-cell microwave and optical atomic clocks designed for the excellent stability rather than accuracy.

arXiv:2405.14281•May 23, 2024•1 citation

1996 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM REDUCING THE LIGHT-SHIFT IN THE DIODE LASER PUMPED RUBIDIUM ATOMIC CLOCK

James C. Camparo

One impediment to achieving the promise of enhanced laser-pumped gas cell clock performance resides with the light-shift effect, a phenomenon whereby diode laser optical frequency fluctuations are mapped onto the atomic clock‘s output frequency. The alternative to tightly stabilizing the diode laser in order to overcome this problem is to develop means of reducing the actual magnitude of the light-shift. Here, we briefly review two strategies for accomplishing this, and introduce a new one based on optical pumping with laser-induced-fluorescence (LIF). The advantage of LIF optical pumping is that the clock‘s output frequency is insensitive to laser frequency fluctuations. Though LIF optical pumping creates a dependence of clock frequency on laser intensity variations, it is to be noted that diode lasers have very low intensity noise. Consequently, with regards to the light-shift effect the LIF strategy takes advantage of an inherent diode laser strength.

•Jan 1, 1996•0 citations
We present a novel, to the best of our knowledge, frequency shift mechanism in the optically detected atomic clock. This frequency shift is analogous to the light shift that is associated with a detecting light power. However, this shift arises from the inhomogeneity of the magnetic field (C-field) and the detecting light intensity. We call this shift the "pseudo-light shift" (p-LS). This shift allows the correlation between the clock output frequency and the detecting light power to switch between positive and negative, depending on the magnetic field. The mechanism is described and experimentally validated in our cesium beam clock through two experiments. The study of this frequency shift can enhance the accuracy of light shift assessments in atom-laser interaction systems and suppress long-term stability deterioration caused by the light power fluctuation.
Light detection is widely used in atomic clocks. The simple detecting structure induces the light shift which influences the clock's long-term stability. We introduce a new method to suppress light shift by using pulsed light instead of continuous light to detect atomic states. Under a suitable pulsed sequence, the part of the atoms which do not simultaneously interact with light and microwave field are detected. We demonstrate the validity of our approach in a magnetic-state-selected cesium beam clock. Using a well-tuned sequence, the light shift coefficient is reduced by a factor of about 10, in comparison with the continuous light detection scheme. In a clock stability test with extra light power noise, the result shows good immunity of the method to laser power fluctuations. We also analyze the sources of the clock short-term stability degradation, including the Dick effect and the fact that a reduced number of atoms is detected in the pulsed detection case.
Atomic vapor magnetometers have demonstrated very high sensitivity to the magnitude of the magnetic field. Vector field measurements are possible using bias fields applied to the vapor. For remote operation, the bias field can be generated using the optical light shift (LS) effect created with an optical beam delivered through optical fiber. Here, it is shown that the optical frequency of the LS effect for an optically pumped vapor vector magnetometer causes an angular error in the measured field orientation when it is tuned near the absorption resonances, countering the benefit of higher response. This angle-shifting effect is dependent on the LS beam power. The LS response, normalized to the LS power, is higher for lower powers due to a saturation effect but also shows a dependence on the LS optical frequency. We show that it is necessary to carefully choose the LS optical frequency and power to maximize the LS effect while avoiding potential angular error.
We show that the light shift in atomic clocks can be suppressed using time variation of the interrogation field intensity. By measuring the clock output at two intensity levels, error signals can be generated that simultaneously stabilize a local oscillator to an atomic transition and correct for the shift of this transition caused by the interrogating optical field. These methods are suitable for optical clocks using one- and two-photon transitions, as well as for microwave clocks based on coherent population trapping or direct interrogation. The proposed methods can be widely used both for high-precision scientific instruments and for a wide range of commercial clocks, including chip-scale atomic clocks.
We derive the frequency shift for a forbidden optical transition $J=0\ensuremath{\rightarrow}{J}^{\ensuremath{'}}=0$ caused by the simultaneous actions of an elliptically polarized lattice field and a static magnetic field. We find that a simple configuration of lattice and magnetic fields leads to a cancellation of this shift to first order in lattice intensity and magnetic field. In this geometry, the second-order lattice intensity shift can be minimized as well by use of optimal lattice polarization. Suppression of these shifts could considerably enhance the performance of the next generation of atomic clocks.
Light shift and vapor-cell temperature shift are the two most significant factors dominating the long-term instability of compact atomic clocks. Due to the different physical mechanisms, there is not yet a solution that can effectively suppress the frequency shifts induced by these two effects. Here, we propose a 'resonance-offset' locking approach that compensates for the two physical frequency shifts. In this approach, the additional offset locking shift can effectively counteract the atomic resonance shifts arising from changes in vapor-cell temperature and light power, reducing the net impact on the clock's frequency to nearly zero. We have demonstrated this strategy on the 778 nm Rubidium two-photon optical frequency standard, successfully compensating for light shift and cell-temperature shift, respectively. This general method is particularly appealing for compact vapor-cell microwave and optical atomic clocks designed for the excellent stability rather than accuracy.
One impediment to achieving the promise of enhanced laser-pumped gas cell clock performance resides with the light-shift effect, a phenomenon whereby diode laser optical frequency fluctuations are mapped onto the atomic clock‘s output frequency. The alternative to tightly stabilizing the diode laser in order to overcome this problem is to develop means of reducing the actual magnitude of the light-shift. Here, we briefly review two strategies for accomplishing this, and introduce a new one based on optical pumping with laser-induced-fluorescence (LIF). The advantage of LIF optical pumping is that the clock‘s output frequency is insensitive to laser frequency fluctuations. Though LIF optical pumping creates a dependence of clock frequency on laser intensity variations, it is to be noted that diode lasers have very low intensity noise. Consequently, with regards to the light-shift effect the LIF strategy takes advantage of an inherent diode laser strength.