Optics Express

Light shift suppression with pulsed light detection in magnetic-state-selected cesium beam clocks

Yuanhao Li, Shaohang Xu, Sifei Chen, Chang Liu, Jiale Wang, Yanhui Wang

Published Oct 26, 2022• 6 citations
Publisher

Abstract

Light detection is widely used in atomic clocks. The simple detecting structure induces the light shift which influences the clock's long-term stability. We introduce a new method to suppress light shift by using pulsed light instead of continuous light to detect atomic states. Under a suitable pulsed sequence, the part of the atoms which do not simultaneously interact with light and microwave field are detected. We demonstrate the validity of our approach in a magnetic-state-selected cesium beam clock. Using a well-tuned sequence, the light shift coefficient is reduced by a factor of about 10, in comparison with the continuous light detection scheme. In a clock stability test with extra light power noise, the result shows good immunity of the method to laser power fluctuations. We also analyze the sources of the clock short-term stability degradation, including the Dick effect and the fact that a reduced number of atoms is detected in the pulsed detection case.

DOI
10.1364/oe.472709

Related papers

Improved long-term stability of pulsed CPT atomic clocks using a modified combined error signal method

Daba A. Radnatarov, Ivan Gromov, Sergey M Kobtsev +2 more

We present an improved technique for suppressing light shift in pulsed CPT atomic clocks by a method of refining the combined error signal (CES). While our earlier implementation successfully eliminated sensitivity to power fluctuations, it failed to improve long-term stability. Through detailed experimental analysis, we identified the key limiting factors and introduced modifications to the pulse sequence, including phase-constrained transitions, composite pulses, and spatial filtering. These advancements enabled us to significantly enhance long-term frequency stability, bringing it close to the theoretical limit. The results confirm the practical feasibility of robust light-shift suppression in miniaturised atomic clocks.

•Oct 10, 2025•0 citations

Frequency shift caused by a magnetic field and light intensity inhomogeneity in an optically detected clock

Yuanhao Li, Chen Liu, Sifei Chen +5 more

We present a novel, to the best of our knowledge, frequency shift mechanism in the optically detected atomic clock. This frequency shift is analogous to the light shift that is associated with a detecting light power. However, this shift arises from the inhomogeneity of the magnetic field (C-field) and the detecting light intensity. We call this shift the "pseudo-light shift" (p-LS). This shift allows the correlation between the clock output frequency and the detecting light power to switch between positive and negative, depending on the magnetic field. The mechanism is described and experimentally validated in our cesium beam clock through two experiments. The study of this frequency shift can enhance the accuracy of light shift assessments in atom-laser interaction systems and suppress long-term stability deterioration caused by the light power fluctuation.

Optics Letters•Oct 21, 2024•0 citations

A new magnetic state selection method in high-performance optically detected compact cesium beam clocks

Sifei Chen, Chen Liu, Lifeng Fan +4 more

We perform a new scheme of magnetic state selection in optically detected compact cesium beam clocks. Unlike the conventional method, we select atoms in the ground state |F = 4, mF ≠ -4⟩ by pointing the atomic collimator to the convex pole of the magnet realizing the two-wire magnetic field and detect atoms in |F = 3⟩ after interacting with the microwave field using a distributed feedback laser. The fluorescence background is greatly reduced as the inherent residual atoms |F = 4, mF = -4⟩ are avoided in this reversed scheme. The velocity distribution is narrowed, and the most probable velocity is decreased, since atomic trajectories are close to the weak-field region. We also investigate the relationship between the position of the atomic collimator and the distributions of the atomic beam, which is consistent with the Monte Carlo-based simulation model. By applying the reversed scheme and setting the deviated position of the collimator to 1.3 mm, the signal contrast is improved from 0.7 to 3, and the short-term frequency stability reaches 3.0 × 10-12 τ-1/2, nearly three times better than that of the high-performance version of Microsemi 5071A.

Review of Scientific Instruments•Apr 1, 2023•5 citations

Reduction of light shifts in a cold-atom CPT clock

Maojie Li, Zhu Ma, Jiatao Wu +5 more

Abstract Light shifts induced during atom–light interactions significantly affect the medium- and long-term frequency stability of atomic clocks. Here, we employ composite laser pulse sequences to mitigate interrogation-induced light shifts in a cold-atom coherent-population-trapping clock. We obtain the anti-symmetry error signal via modulating the local oscillator phase in the free-evolution time of Ramsey interferometry. Utilizing this signal, we employ two feedback loops to simultaneously eliminate light shifts and stabilize the clock frequency using the auto-balanced Ramsey (ABR) spectroscopy scheme. Our experimental results demonstrate that this approach can reduce the clock frequency’s sensitivity to variations in light shifts by implementing four Ramsey sub-sequences. Furthermore, we show that the ABR spectroscopy scheme enhances the long-term frequency stability of the atomic clock when the averaging time τ > 5000 s.

Journal of Physics B Atomic Molecular and Optical Physics•Apr 23, 2024•4 citations

Simple method of light-shift suppression in optical pumping systems

B. H. McGuyer, Yuan‐Yu Jau, W. Happer

We report a simple method to suppress the light shift in optical pumping systems. This method uses only frequency modulation of a radio frequency or microwave source, which is used to excite an atomic resonance, to simultaneously lock the source frequency to the atomic resonance and lock the pumping light frequency to suppress the light shift. We experimentally validate the method in a vapor-cell atomic clock and verify the results through numerical simulation. This technique can be applied to many optical pumping systems that experience light shifts. It is especially useful for atomic frequency standards because it improves long-term performance, reduces the influence of the laser, and requires less equipment than previous methods.

arXiv:1302.4160•Applied Physics Letters•Jun 22, 2009•59 citations

General Methods for Suppressing the Light Shift in Atomic Clocks Using Power Modulation

Valeriy I. Yudin, M. Yu. Basalaev, А. В. Тайченачев +8 more

We show that the light shift in atomic clocks can be suppressed using time variation of the interrogation field intensity. By measuring the clock output at two intensity levels, error signals can be generated that simultaneously stabilize a local oscillator to an atomic transition and correct for the shift of this transition caused by the interrogating optical field. These methods are suitable for optical clocks using one- and two-photon transitions, as well as for microwave clocks based on coherent population trapping or direct interrogation. The proposed methods can be widely used both for high-precision scientific instruments and for a wide range of commercial clocks, including chip-scale atomic clocks.

arXiv:1911.02935•Physical Review Applied•Aug 3, 2020•43 citations
Light detection is widely used in atomic clocks. The simple detecting structure induces the light shift which influences the clock's long-term stability. We introduce a new method to suppress light shift by using pulsed light instead of continuous light to detect atomic states. Under a suitable pulsed sequence, the part of the atoms which do not simultaneously interact with light and microwave field are detected. We demonstrate the validity of our approach in a magnetic-state-selected cesium beam clock. Using a well-tuned sequence, the light shift coefficient is reduced by a factor of about 10, in comparison with the continuous light detection scheme. In a clock stability test with extra light power noise, the result shows good immunity of the method to laser power fluctuations. We also analyze the sources of the clock short-term stability degradation, including the Dick effect and the fact that a reduced number of atoms is detected in the pulsed detection case.
We present an improved technique for suppressing light shift in pulsed CPT atomic clocks by a method of refining the combined error signal (CES). While our earlier implementation successfully eliminated sensitivity to power fluctuations, it failed to improve long-term stability. Through detailed experimental analysis, we identified the key limiting factors and introduced modifications to the pulse sequence, including phase-constrained transitions, composite pulses, and spatial filtering. These advancements enabled us to significantly enhance long-term frequency stability, bringing it close to the theoretical limit. The results confirm the practical feasibility of robust light-shift suppression in miniaturised atomic clocks.
We present a novel, to the best of our knowledge, frequency shift mechanism in the optically detected atomic clock. This frequency shift is analogous to the light shift that is associated with a detecting light power. However, this shift arises from the inhomogeneity of the magnetic field (C-field) and the detecting light intensity. We call this shift the "pseudo-light shift" (p-LS). This shift allows the correlation between the clock output frequency and the detecting light power to switch between positive and negative, depending on the magnetic field. The mechanism is described and experimentally validated in our cesium beam clock through two experiments. The study of this frequency shift can enhance the accuracy of light shift assessments in atom-laser interaction systems and suppress long-term stability deterioration caused by the light power fluctuation.
We perform a new scheme of magnetic state selection in optically detected compact cesium beam clocks. Unlike the conventional method, we select atoms in the ground state |F = 4, mF ≠ -4⟩ by pointing the atomic collimator to the convex pole of the magnet realizing the two-wire magnetic field and detect atoms in |F = 3⟩ after interacting with the microwave field using a distributed feedback laser. The fluorescence background is greatly reduced as the inherent residual atoms |F = 4, mF = -4⟩ are avoided in this reversed scheme. The velocity distribution is narrowed, and the most probable velocity is decreased, since atomic trajectories are close to the weak-field region. We also investigate the relationship between the position of the atomic collimator and the distributions of the atomic beam, which is consistent with the Monte Carlo-based simulation model. By applying the reversed scheme and setting the deviated position of the collimator to 1.3 mm, the signal contrast is improved from 0.7 to 3, and the short-term frequency stability reaches 3.0 × 10-12 τ-1/2, nearly three times better than that of the high-performance version of Microsemi 5071A.
Abstract Light shifts induced during atom–light interactions significantly affect the medium- and long-term frequency stability of atomic clocks. Here, we employ composite laser pulse sequences to mitigate interrogation-induced light shifts in a cold-atom coherent-population-trapping clock. We obtain the anti-symmetry error signal via modulating the local oscillator phase in the free-evolution time of Ramsey interferometry. Utilizing this signal, we employ two feedback loops to simultaneously eliminate light shifts and stabilize the clock frequency using the auto-balanced Ramsey (ABR) spectroscopy scheme. Our experimental results demonstrate that this approach can reduce the clock frequency’s sensitivity to variations in light shifts by implementing four Ramsey sub-sequences. Furthermore, we show that the ABR spectroscopy scheme enhances the long-term frequency stability of the atomic clock when the averaging time τ > 5000 s.
We report a simple method to suppress the light shift in optical pumping systems. This method uses only frequency modulation of a radio frequency or microwave source, which is used to excite an atomic resonance, to simultaneously lock the source frequency to the atomic resonance and lock the pumping light frequency to suppress the light shift. We experimentally validate the method in a vapor-cell atomic clock and verify the results through numerical simulation. This technique can be applied to many optical pumping systems that experience light shifts. It is especially useful for atomic frequency standards because it improves long-term performance, reduces the influence of the laser, and requires less equipment than previous methods.
We show that the light shift in atomic clocks can be suppressed using time variation of the interrogation field intensity. By measuring the clock output at two intensity levels, error signals can be generated that simultaneously stabilize a local oscillator to an atomic transition and correct for the shift of this transition caused by the interrogating optical field. These methods are suitable for optical clocks using one- and two-photon transitions, as well as for microwave clocks based on coherent population trapping or direct interrogation. The proposed methods can be widely used both for high-precision scientific instruments and for a wide range of commercial clocks, including chip-scale atomic clocks.