Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Cryogenic Platforms at Fermilab: Recent Results and Outlook

Dylan J. Temples

Published Sep 10, 2024• 0 citations
Publisher

Abstract

The Cosmic Quantum group at Fermilab operates three cryogenic facilities dedicated to the development and calibration of superconducting low-threshold detectors and qubits. One of which (LOUD) is located at the surface, while the other two (NEXUS and QUIET) are located 100 m underground enabling low-background device characterization and rare event searches. Recently, we have demonstrated world-leading resolution in the quasiparticle channel for kinetic inductance phonon-mediated detectors as well as the lowest rate of spatially- and temporally- correlated errors ( charge jumps ) in superconducting qubit chips. We have additionally made significant progress in expanding the suite of tools for simulating signal production and readout of these devices. In this talk, I will review these recent results, discuss some nascent projects focused on enhancing sensitivity of these detectors to sub-GeV dark matter, and highlight activities in these facilities over the next year.

DOI
10.2172/2440228

Related papers

Cryogenic optical beam steering for characterization of quantum sensors

Kelly Stifter

Currently, there is a critical need for localized, position-dependent calibration of quantum device response to characterize the fundamental sensing mechanism of many superconducting detectors. For example, qubit decoherence has been found to be associated with the generation of electron-hole pairs and phonons through the scattering of radiation in the qubit substrate. Novel particle physics applications seek to use these events as indicators of energy deposition, allowing quantum devices to serve as particle detectors. The low energy threshold of these proposed detectors makes them particularly well-suited for a next-generation dark matter search. We have developed a cryogenic optical beam steering system that delivers monochromatic photons in the range of 250nm - 20um across the surface of any cryogenic quantum device. In this talk, I will present the design overview and specifications of this calibration unit, along with current status and plans of the testing program.

Optical and Quantum Sensing and Precision Metrology II•Mar 8, 2023•0 citations

Enabling Measurements of Qubit Errors at NEXUS

Alexander Novara, Sami Lewis, D. Bowring

MotivationAs qubit technology progresses, one intriguing application involves their use as low noise single photon detectors.By measuring how the readout frequency of a resonator coupled to the qubit shifts in the presence of a photon, faint signals can be distinguished from mK-scale thermal noise.With this sensitivity, phenomena such as axion conversion to photons may be detectable.Axion conversion to photon: ongoing and future experiments will explore regions of axion parameter space that correspond to axion-dominated dark matter.Though they have long been viewed a promising dark matter candidate, some DMplausible axion mass values have thus far been difficult to probe via conventional photon counting techniques due to weak signal strength relative to noise.Recent scholarship suggests that ionizing radiation may cause major issues in qubits, namely decoherence and 'catastrophic' correlated errors across time and space.Compromised coherence constrains all qubit applications, while such multi-qubit errors break current error-correction algorithms.We are using NEXUS-Northwestern EXperimental Underground Site at Fermilab-to measure the impact of a low-radiation environment on qubit experiments.If a material difference in coherence time and/or error rate is detected, future qubit applications may need to be designed with such conclusions in mind.

•Jan 1, 2021•0 citations

Quantum parity detectors: A qubit-based particle-detection scheme with meV thresholds for rare-event searches

Karthik Ramanathan, Brandon J. Sandoval, J. E. Parker +5 more

The next generation of rare-event searches, such as those aimed at determining the nature of particle dark matter or measuring fundamental neutrino properties, will benefit from particle detectors with thresholds at the meV scale, 100 – 1000 × lower than currently available. Quantum parity detectors (QPDs) are a class of proposed quantum devices, extending recent work on superconducting qubit sensors, that exploit the fingerprints of single quasiparticle tunneling across a coherent weak link as their detection concept. As envisioned, phonons generated by particle interactions within a crystalline substrate cause an eventual quasiparticle cascade within a surface-patterned superconducting qubit element. This process alters the fundamental charge parity of the device in a binary manner, which can be used to deduce the initial properties of the energy deposition. This work lays out multiple resonator-coupled readout schemes depending on qubit architecture, provides an analytic formulation for reconstructing sensor energies, and details strategies for multiplexing large arrays of sensors. We further compute the sensitivity of QPDs and detail an R&D pathway to demonstrating sub-eV energy deposit thresholds.

arXiv:2405.17192•APS Open Science•Apr 30, 2026•21 citations

Measurement of correlated charge noise in superconducting qubits at an underground facility

G. Bratrud, Samantha M. Lewis, K. Anyang +35 more

Abstract The charge environment of superconducting qubits may be studied through the introduction of controlled, quantified amounts of ionizing radiation. We measure space- and time-correlated charge jumps on a four-qubit device, operating 107 meters below the Earth’s surface in a low-radiation, cryogenic facility designed for the characterization of low-threshold particle detectors. The rock overburden of this facility reduces the cosmic ray muon flux by over 99% compared to laboratories at sea level. Combined with 4 π coverage of a movable lead shield, this facility enables quantifiable control over the flux of ionizing radiation on the qubit device. Long-time-series charge tomography measurements on these weakly charge-sensitive qubits capture discontinuous jumps in the induced charge on the qubit islands, corresponding to the interaction of ionizing radiation with the qubit substrate. The rate of these charge jumps scales with the flux of ionizing radiation on the qubit package, as characterized by a series of independent measurements on another energy-resolving detector operating simultaneously in the same cryostat with the qubits. Using lead shielding, we achieve a minimum charge jump rate of $$0.1{9}_{-0.03}^{+0.04}$$ 0.1 9 − 0.03 + 0.04 mHz, almost an order of magnitude lower than that measured in surface tests, but a factor of roughly seven higher than expected based on reduction of ambient gammas alone. We operate four qubits for over 22 consecutive hours with zero correlated charge jumps at length scales above three millimeters.

arXiv:2405.04642•Nature Communications•Nov 11, 2025•18 citations

Evaluating Radiation Impact on Superconducting Transmon Qubits in Above and Underground Facilities

Tanay Roy, Francesco De Dominicis, Ambra Mariani +18 more

Superconducting qubits can be sensitive to sudden energy deposits into the substrate from cosmic rays and ambient radioactivity. While previous studies have primarily focused on exploring correlated effects over time and distance due to cosmic rays, this study uniquely offers a direct comparison of a transmon qubit's response at Fermilab SQMS above-ground facilities and the deep-underground Gran Sasso Laboratory (INFN-LNGS, Italy). Despite the vastly different radiation environments, we observe a similar average qubit lifetime (T1) of approximately 80 microseconds at both sites. We then employ a fast decay detection protocol and investigate the time structure, sensitivity, and relative rates of triggered events due to radiation versus intrinsic noise. We compare the above and underground performance of several high-coherence qubits with similar designs. Our findings reveal no significant difference in events with radiation-like signatures between above-ground and underground conditions for these sapphire and niobium-based transmon qubits. This suggests that most such events are likely due to other noise sources, which predominantly contribute to single-qubit errors in contemporary transmon qubits. By exposing the qubits to gamma sources with varying activity levels, we further evaluate their response to radiation in a low-background environment. The results show that qubits can indeed detect particle impacts; however, this capability is only realized by substantially reducing other noise sources, which in turn affects detection efficiency [1].

•Sep 20, 2024•0 citations

Evaluating Radiation Impact on Transmon Qubits in Above and Underground Facilities

Tanay Roy, Francesco De Dominicis, Ambra Mariani +17 more

Superconducting qubits can be sensitive to abrupt energy deposits caused by cosmic rays and ambient radioactivity. Previous studies have focused on understanding possible correlated effects over time and distance due to cosmic rays. In this study, for the first time, we directly compare the response of a transmon qubit measured initially at the Fermilab SQMS above-ground facilities and then at the deep underground Gran Sasso Laboratory (INFN-LNGS, Italy). We observe same average qubit lifetime T$_1$ of roughly 80 microseconds at above and underground facilities. We then apply a fast decay detection protocol and investigate the time structure, sensitivity and relative rates of triggered events due to radiation versus intrinsic noise, comparing above and underground performance of several high-coherence qubits. Using gamma sources of variable activity we calibrate the response of the qubit to different levels of radiation in an environment with minimal background radiation. Results indicate that qubits respond to a strong gamma source and it is possible to detect particle impacts. However, when comparing above and underground results, we do not observe a difference in radiation induced-like events for these sapphire and niobium-based transmon qubits. We conclude that the majority of these events are not radiation related and to be attributed to other noise sources which by far dominate single qubit errors in modern transmon qubits.

arXiv:2405.18355•Aug 6, 2024•13 citations
The Cosmic Quantum group at Fermilab operates three cryogenic facilities dedicated to the development and calibration of superconducting low-threshold detectors and qubits. One of which (LOUD) is located at the surface, while the other two (NEXUS and QUIET) are located 100 m underground enabling low-background device characterization and rare event searches. Recently, we have demonstrated world-leading resolution in the quasiparticle channel for kinetic inductance phonon-mediated detectors as well as the lowest rate of spatially- and temporally- correlated errors ( charge jumps ) in superconducting qubit chips. We have additionally made significant progress in expanding the suite of tools for simulating signal production and readout of these devices. In this talk, I will review these recent results, discuss some nascent projects focused on enhancing sensitivity of these detectors to sub-GeV dark matter, and highlight activities in these facilities over the next year.
Currently, there is a critical need for localized, position-dependent calibration of quantum device response to characterize the fundamental sensing mechanism of many superconducting detectors. For example, qubit decoherence has been found to be associated with the generation of electron-hole pairs and phonons through the scattering of radiation in the qubit substrate. Novel particle physics applications seek to use these events as indicators of energy deposition, allowing quantum devices to serve as particle detectors. The low energy threshold of these proposed detectors makes them particularly well-suited for a next-generation dark matter search. We have developed a cryogenic optical beam steering system that delivers monochromatic photons in the range of 250nm - 20um across the surface of any cryogenic quantum device. In this talk, I will present the design overview and specifications of this calibration unit, along with current status and plans of the testing program.
MotivationAs qubit technology progresses, one intriguing application involves their use as low noise single photon detectors.By measuring how the readout frequency of a resonator coupled to the qubit shifts in the presence of a photon, faint signals can be distinguished from mK-scale thermal noise.With this sensitivity, phenomena such as axion conversion to photons may be detectable.Axion conversion to photon: ongoing and future experiments will explore regions of axion parameter space that correspond to axion-dominated dark matter.Though they have long been viewed a promising dark matter candidate, some DMplausible axion mass values have thus far been difficult to probe via conventional photon counting techniques due to weak signal strength relative to noise.Recent scholarship suggests that ionizing radiation may cause major issues in qubits, namely decoherence and 'catastrophic' correlated errors across time and space.Compromised coherence constrains all qubit applications, while such multi-qubit errors break current error-correction algorithms.We are using NEXUS-Northwestern EXperimental Underground Site at Fermilab-to measure the impact of a low-radiation environment on qubit experiments.If a material difference in coherence time and/or error rate is detected, future qubit applications may need to be designed with such conclusions in mind.
The next generation of rare-event searches, such as those aimed at determining the nature of particle dark matter or measuring fundamental neutrino properties, will benefit from particle detectors with thresholds at the meV scale, 100 – 1000 × lower than currently available. Quantum parity detectors (QPDs) are a class of proposed quantum devices, extending recent work on superconducting qubit sensors, that exploit the fingerprints of single quasiparticle tunneling across a coherent weak link as their detection concept. As envisioned, phonons generated by particle interactions within a crystalline substrate cause an eventual quasiparticle cascade within a surface-patterned superconducting qubit element. This process alters the fundamental charge parity of the device in a binary manner, which can be used to deduce the initial properties of the energy deposition. This work lays out multiple resonator-coupled readout schemes depending on qubit architecture, provides an analytic formulation for reconstructing sensor energies, and details strategies for multiplexing large arrays of sensors. We further compute the sensitivity of QPDs and detail an R&D pathway to demonstrating sub-eV energy deposit thresholds.
Abstract The charge environment of superconducting qubits may be studied through the introduction of controlled, quantified amounts of ionizing radiation. We measure space- and time-correlated charge jumps on a four-qubit device, operating 107 meters below the Earth’s surface in a low-radiation, cryogenic facility designed for the characterization of low-threshold particle detectors. The rock overburden of this facility reduces the cosmic ray muon flux by over 99% compared to laboratories at sea level. Combined with 4 π coverage of a movable lead shield, this facility enables quantifiable control over the flux of ionizing radiation on the qubit device. Long-time-series charge tomography measurements on these weakly charge-sensitive qubits capture discontinuous jumps in the induced charge on the qubit islands, corresponding to the interaction of ionizing radiation with the qubit substrate. The rate of these charge jumps scales with the flux of ionizing radiation on the qubit package, as characterized by a series of independent measurements on another energy-resolving detector operating simultaneously in the same cryostat with the qubits. Using lead shielding, we achieve a minimum charge jump rate of 0.19−0.03+0.040.1{9}_{-0.03}^{+0.04}0.19−0.03+0.04​ 0.1 9 − 0.03 + 0.04 mHz, almost an order of magnitude lower than that measured in surface tests, but a factor of roughly seven higher than expected based on reduction of ambient gammas alone. We operate four qubits for over 22 consecutive hours with zero correlated charge jumps at length scales above three millimeters.
Superconducting qubits can be sensitive to sudden energy deposits into the substrate from cosmic rays and ambient radioactivity. While previous studies have primarily focused on exploring correlated effects over time and distance due to cosmic rays, this study uniquely offers a direct comparison of a transmon qubit's response at Fermilab SQMS above-ground facilities and the deep-underground Gran Sasso Laboratory (INFN-LNGS, Italy). Despite the vastly different radiation environments, we observe a similar average qubit lifetime (T1) of approximately 80 microseconds at both sites. We then employ a fast decay detection protocol and investigate the time structure, sensitivity, and relative rates of triggered events due to radiation versus intrinsic noise. We compare the above and underground performance of several high-coherence qubits with similar designs. Our findings reveal no significant difference in events with radiation-like signatures between above-ground and underground conditions for these sapphire and niobium-based transmon qubits. This suggests that most such events are likely due to other noise sources, which predominantly contribute to single-qubit errors in contemporary transmon qubits. By exposing the qubits to gamma sources with varying activity levels, we further evaluate their response to radiation in a low-background environment. The results show that qubits can indeed detect particle impacts; however, this capability is only realized by substantially reducing other noise sources, which in turn affects detection efficiency [1].
Superconducting qubits can be sensitive to abrupt energy deposits caused by cosmic rays and ambient radioactivity. Previous studies have focused on understanding possible correlated effects over time and distance due to cosmic rays. In this study, for the first time, we directly compare the response of a transmon qubit measured initially at the Fermilab SQMS above-ground facilities and then at the deep underground Gran Sasso Laboratory (INFN-LNGS, Italy). We observe same average qubit lifetime T1_11​ of roughly 80 microseconds at above and underground facilities. We then apply a fast decay detection protocol and investigate the time structure, sensitivity and relative rates of triggered events due to radiation versus intrinsic noise, comparing above and underground performance of several high-coherence qubits. Using gamma sources of variable activity we calibrate the response of the qubit to different levels of radiation in an environment with minimal background radiation. Results indicate that qubits respond to a strong gamma source and it is possible to detect particle impacts. However, when comparing above and underground results, we do not observe a difference in radiation induced-like events for these sapphire and niobium-based transmon qubits. We conclude that the majority of these events are not radiation related and to be attributed to other noise sources which by far dominate single qubit errors in modern transmon qubits.