Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Enabling Measurements of Qubit Errors at NEXUS

Alexander Novara, Sami Lewis, D. Bowring

Published Jan 1, 2021• 0 citations
Publisher

Abstract

MotivationAs qubit technology progresses, one intriguing application involves their use as low noise single photon detectors.By measuring how the readout frequency of a resonator coupled to the qubit shifts in the presence of a photon, faint signals can be distinguished from mK-scale thermal noise.With this sensitivity, phenomena such as axion conversion to photons may be detectable.Axion conversion to photon: ongoing and future experiments will explore regions of axion parameter space that correspond to axion-dominated dark matter.Though they have long been viewed a promising dark matter candidate, some DMplausible axion mass values have thus far been difficult to probe via conventional photon counting techniques due to weak signal strength relative to noise.Recent scholarship suggests that ionizing radiation may cause major issues in qubits, namely decoherence and 'catastrophic' correlated errors across time and space.Compromised coherence constrains all qubit applications, while such multi-qubit errors break current error-correction algorithms.We are using NEXUS-Northwestern EXperimental Underground Site at Fermilab-to measure the impact of a low-radiation environment on qubit experiments.If a material difference in coherence time and/or error rate is detected, future qubit applications may need to be designed with such conclusions in mind.

DOI
10.2172/1838493

Related papers

Searching for Dark Matter with a Superconducting Qubit

Akash V. Dixit, Srivatsan Chakram, Kevin T. He +4 more

Detection mechanisms for low mass bosonic dark matter candidates, such as the axion or hidden photon, leverage potential interactions with electromagnetic fields, whereby the dark matter (of unknown mass) on rare occasion converts into a single photon. Current dark matter searches operating at microwave frequencies use a resonant cavity to coherently accumulate the field sourced by the dark matter and a near standard quantum limited (SQL) linear amplifier to read out the cavity signal. To further increase sensitivity to the dark matter signal, sub-SQL detection techniques are required. Here we report the development of a novel microwave photon counting technique and a new exclusion limit on hidden photon dark matter. We operate a superconducting qubit to make repeated quantum nondemolition measurements of cavity photons and apply a hidden Markov model analysis to reduce the noise to 15.7 dB below the quantum limit, with overall detector performance limited by a residual background of real photons. With the present device, we perform a hidden photon search and constrain the kinetic mixing angle to ε≤1.68×10^{-15} in a band around 6.011 GHz (24.86 μeV) with an integration time of 8.33 s. This demonstrated noise reduction technique enables future dark matter searches to be sped up by a factor of 1,300. By coupling a qubit to an arbitrary quantum sensor, more general sub-SQL metrology is possible with the techniques presented in this Letter.

arXiv:2008.12231•Physical Review Letters•Apr 8, 2021•218 citations

Accelerating dark-matter axion searches with quantum measurement technology

Huaixiu Zheng, Matti Silveri, Richard Brierley +2 more

The axion particle, a consequence of an elegant hypothesis that resolves the strong-CP problem of quantum chromodynamics, is a plausible origin for cosmological dark matter. In searches for axionic dark matter that detect the conversion of axions to microwave photons, the quantum noise associated with microwave vacuum fluctuations will soon limit the rate at which parameter space is searched. Here we show that this noise can be partially overcome either by squeezing the quantum vacuum using recently developed Josephson parametric devices, or by using superconducting qubits to count microwave photons. The recently demonstrated ability of superconducting qubits to make QND measurements of microwave photons offers great advantages over destructive photon counting methods such as those using Rydberg atoms.

arXiv:1607.02529•Jul 8, 2016•67 citations

Boosting Axion Searches with Quantum Sensing

Claudio D. Gatti

The axion, a pseudoscalar particle originally introduced by Peccei, Quinn, Weinberg, and Wilczek to solve the "strong CP problem", is a well motivated dark-matter candidate with a mass lying in a broad range from peV to few meV. The last decade witnessed an increasing interest in axions and axion-like particles with many theoretical works published and many new experimental proposals. A major challenge for cosmological-axion discovery is the detection of the faint signal expected in detectors with power as low as a fraction of yoctowatt corresponding to a single microwave photon per minute. Early experiments used GaAs field-effect-transistors as well as pioneering technology such as Rydberg-atom single-photon detection. In the attempt of reducing the noise temperature superconductive devices were soon introduced. Microstrip SQUID Amplifiers allowed SQUIDs to operate at frequencies of a few GHz with a noise temperature reaching the standard quantum limit. Josephson Parametric Amplifiers have been recently employed extending the search to higher frequency while boradband Traveling Wave Parametric Amplifiers are now under study. The ultimate sensitivity, beyond the quantum limit, is however expected from single microwave-photon detectors. Solutions for quantum sensing include quantum non-demolition measurements and switching detectors based on superconducting qubits and hot-electron detectors. A further improvement in signal sensitivity and noise reduction is expected exploiting arrays of superconducting qubits as proposed by the SUPERGALAX project.

IEEE Workshop on Low Temperature Electronics (WOLTE)•Apr 12, 2021•1 citation

Evaluating Radiation Impact on Transmon Qubits in Above and Underground Facilities

Tanay Roy, Francesco De Dominicis, Ambra Mariani +17 more

Superconducting qubits can be sensitive to abrupt energy deposits caused by cosmic rays and ambient radioactivity. Previous studies have focused on understanding possible correlated effects over time and distance due to cosmic rays. In this study, for the first time, we directly compare the response of a transmon qubit measured initially at the Fermilab SQMS above-ground facilities and then at the deep underground Gran Sasso Laboratory (INFN-LNGS, Italy). We observe same average qubit lifetime T$_1$ of roughly 80 microseconds at above and underground facilities. We then apply a fast decay detection protocol and investigate the time structure, sensitivity and relative rates of triggered events due to radiation versus intrinsic noise, comparing above and underground performance of several high-coherence qubits. Using gamma sources of variable activity we calibrate the response of the qubit to different levels of radiation in an environment with minimal background radiation. Results indicate that qubits respond to a strong gamma source and it is possible to detect particle impacts. However, when comparing above and underground results, we do not observe a difference in radiation induced-like events for these sapphire and niobium-based transmon qubits. We conclude that the majority of these events are not radiation related and to be attributed to other noise sources which by far dominate single qubit errors in modern transmon qubits.

arXiv:2405.18355•Aug 6, 2024•13 citations

Dark matter detection with superconducting qubit in RADES experiment

Yikun Gu

In dark matter detection especially for ultra light dark matter such as axion or axion-like particles, the output signals are easily buried in noise, making it challenging to reach the expected sensitivity. Recently, various detection concepts incorporating quantum technology are being explored to overcome this limitation. One of the most exciting one is with superconducting qubits as a single photon counter. In this talk we will discuss the ongoing work to develop quantum sensing with superconducting qubit in the RADES experiment.

General Meeting and Training School of the COST Action COSMIC WISPers (COSMICWISPers)•Feb 5, 2025•1 citation

Searching for Dark Matter with Superconducting Qubits

Akash V. Dixit

Dark matter is an enduring mystery in our quest to understand the fundamental constituents of our universe. Low mass bosons, such the axion or hidden photon, are compelling dark matter candidates. We leverage their potential interactions with electromagnetic fields, whereby the dark matter (of unknown mass) on rare occasion converts into a single photon, to devise a method of detecting these candidates. Current dark matter searches operating at microwave frequencies use a resonant cavity to coherently accumulate the field sourced by the dark matter and a near standard quantum limited (SQL) linear amplifier to read out the cavity signal. To further increase sensitivity to the dark matter signal and enable future searches, sub-SQL detection techniques are required. In this thesis, I report the development of a novel microwave photon counting technique and a new exclusion limit on hidden photon dark matter. We operate a superconducting qubit to make repeated quantum non-demolition measurements of cavity photons and apply a hidden Markov model analysis to reduce the noise to 15.7 dB below the quantum limit, with overall detector performance limited by a residual background of real photons. With the present device, we perform a hidden photon search and constrain the kinetic mixing angle to less than 1.68 X 10^{-15} in a band around 6.011 GHz (24.86 micro-eV) with an integration time of 8.33 s. This demonstrated noise reduction technique enables future dark matter searches to be sped up by a factor of 1300. By coupling a qubit to an arbitrary quantum sensor, more general sub-SQL metrology is possible with the techniques presented in this work.

•Jun 1, 2021•0 citations
MotivationAs qubit technology progresses, one intriguing application involves their use as low noise single photon detectors.By measuring how the readout frequency of a resonator coupled to the qubit shifts in the presence of a photon, faint signals can be distinguished from mK-scale thermal noise.With this sensitivity, phenomena such as axion conversion to photons may be detectable.Axion conversion to photon: ongoing and future experiments will explore regions of axion parameter space that correspond to axion-dominated dark matter.Though they have long been viewed a promising dark matter candidate, some DMplausible axion mass values have thus far been difficult to probe via conventional photon counting techniques due to weak signal strength relative to noise.Recent scholarship suggests that ionizing radiation may cause major issues in qubits, namely decoherence and 'catastrophic' correlated errors across time and space.Compromised coherence constrains all qubit applications, while such multi-qubit errors break current error-correction algorithms.We are using NEXUS-Northwestern EXperimental Underground Site at Fermilab-to measure the impact of a low-radiation environment on qubit experiments.If a material difference in coherence time and/or error rate is detected, future qubit applications may need to be designed with such conclusions in mind.
Detection mechanisms for low mass bosonic dark matter candidates, such as the axion or hidden photon, leverage potential interactions with electromagnetic fields, whereby the dark matter (of unknown mass) on rare occasion converts into a single photon. Current dark matter searches operating at microwave frequencies use a resonant cavity to coherently accumulate the field sourced by the dark matter and a near standard quantum limited (SQL) linear amplifier to read out the cavity signal. To further increase sensitivity to the dark matter signal, sub-SQL detection techniques are required. Here we report the development of a novel microwave photon counting technique and a new exclusion limit on hidden photon dark matter. We operate a superconducting qubit to make repeated quantum nondemolition measurements of cavity photons and apply a hidden Markov model analysis to reduce the noise to 15.7 dB below the quantum limit, with overall detector performance limited by a residual background of real photons. With the present device, we perform a hidden photon search and constrain the kinetic mixing angle to ε≤1.68×10^{-15} in a band around 6.011 GHz (24.86 μeV) with an integration time of 8.33 s. This demonstrated noise reduction technique enables future dark matter searches to be sped up by a factor of 1,300. By coupling a qubit to an arbitrary quantum sensor, more general sub-SQL metrology is possible with the techniques presented in this Letter.
The axion particle, a consequence of an elegant hypothesis that resolves the strong-CP problem of quantum chromodynamics, is a plausible origin for cosmological dark matter. In searches for axionic dark matter that detect the conversion of axions to microwave photons, the quantum noise associated with microwave vacuum fluctuations will soon limit the rate at which parameter space is searched. Here we show that this noise can be partially overcome either by squeezing the quantum vacuum using recently developed Josephson parametric devices, or by using superconducting qubits to count microwave photons. The recently demonstrated ability of superconducting qubits to make QND measurements of microwave photons offers great advantages over destructive photon counting methods such as those using Rydberg atoms.
The axion, a pseudoscalar particle originally introduced by Peccei, Quinn, Weinberg, and Wilczek to solve the "strong CP problem", is a well motivated dark-matter candidate with a mass lying in a broad range from peV to few meV. The last decade witnessed an increasing interest in axions and axion-like particles with many theoretical works published and many new experimental proposals. A major challenge for cosmological-axion discovery is the detection of the faint signal expected in detectors with power as low as a fraction of yoctowatt corresponding to a single microwave photon per minute. Early experiments used GaAs field-effect-transistors as well as pioneering technology such as Rydberg-atom single-photon detection. In the attempt of reducing the noise temperature superconductive devices were soon introduced. Microstrip SQUID Amplifiers allowed SQUIDs to operate at frequencies of a few GHz with a noise temperature reaching the standard quantum limit. Josephson Parametric Amplifiers have been recently employed extending the search to higher frequency while boradband Traveling Wave Parametric Amplifiers are now under study. The ultimate sensitivity, beyond the quantum limit, is however expected from single microwave-photon detectors. Solutions for quantum sensing include quantum non-demolition measurements and switching detectors based on superconducting qubits and hot-electron detectors. A further improvement in signal sensitivity and noise reduction is expected exploiting arrays of superconducting qubits as proposed by the SUPERGALAX project.
Superconducting qubits can be sensitive to abrupt energy deposits caused by cosmic rays and ambient radioactivity. Previous studies have focused on understanding possible correlated effects over time and distance due to cosmic rays. In this study, for the first time, we directly compare the response of a transmon qubit measured initially at the Fermilab SQMS above-ground facilities and then at the deep underground Gran Sasso Laboratory (INFN-LNGS, Italy). We observe same average qubit lifetime T1_11​ of roughly 80 microseconds at above and underground facilities. We then apply a fast decay detection protocol and investigate the time structure, sensitivity and relative rates of triggered events due to radiation versus intrinsic noise, comparing above and underground performance of several high-coherence qubits. Using gamma sources of variable activity we calibrate the response of the qubit to different levels of radiation in an environment with minimal background radiation. Results indicate that qubits respond to a strong gamma source and it is possible to detect particle impacts. However, when comparing above and underground results, we do not observe a difference in radiation induced-like events for these sapphire and niobium-based transmon qubits. We conclude that the majority of these events are not radiation related and to be attributed to other noise sources which by far dominate single qubit errors in modern transmon qubits.
In dark matter detection especially for ultra light dark matter such as axion or axion-like particles, the output signals are easily buried in noise, making it challenging to reach the expected sensitivity. Recently, various detection concepts incorporating quantum technology are being explored to overcome this limitation. One of the most exciting one is with superconducting qubits as a single photon counter. In this talk we will discuss the ongoing work to develop quantum sensing with superconducting qubit in the RADES experiment.
Dark matter is an enduring mystery in our quest to understand the fundamental constituents of our universe. Low mass bosons, such the axion or hidden photon, are compelling dark matter candidates. We leverage their potential interactions with electromagnetic fields, whereby the dark matter (of unknown mass) on rare occasion converts into a single photon, to devise a method of detecting these candidates. Current dark matter searches operating at microwave frequencies use a resonant cavity to coherently accumulate the field sourced by the dark matter and a near standard quantum limited (SQL) linear amplifier to read out the cavity signal. To further increase sensitivity to the dark matter signal and enable future searches, sub-SQL detection techniques are required. In this thesis, I report the development of a novel microwave photon counting technique and a new exclusion limit on hidden photon dark matter. We operate a superconducting qubit to make repeated quantum non-demolition measurements of cavity photons and apply a hidden Markov model analysis to reduce the noise to 15.7 dB below the quantum limit, with overall detector performance limited by a residual background of real photons. With the present device, we perform a hidden photon search and constrain the kinetic mixing angle to less than 1.68 X 10^{-15} in a band around 6.011 GHz (24.86 micro-eV) with an integration time of 8.33 s. This demonstrated noise reduction technique enables future dark matter searches to be sped up by a factor of 1300. By coupling a qubit to an arbitrary quantum sensor, more general sub-SQL metrology is possible with the techniques presented in this work.