Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Conference on Precision Electromagnetic Measurements

Vectorial Operation of a Bell-Bloom Atomic Magnetometer Assisted by Artificial Neural Network

Zhiyuan Jiang, Jianan Qin, Pengbo Jiang, Jinxin Xu, Jifeng Qu

Published Jul 8, 2024• 0 citations
Publisher

Abstract

This paper reports an all-optical vectorial operation method of a Bell-Bloom magnetometer. The spin projections in x and y axes are detected simultaneously by the dual probing beams configuration. And the vector information can be extracted from the phases of spin projection signals. By introducing an artificial neural network (ANN) to establish the relationship between signals and field direction, the phase errors are corrected automatically. With the assistance of ANN, the accuracy of the system has been greatly improved and dead zones have been eliminated basically.

DOI
10.1109/cpem61406.2024.10645974

Related papers

Enhanced all-optical vector atomic magnetometer enabled by artificial neural network

Jianan Qin, Jinxin Xu, Zhiyuan Jiang +1 more

This paper reports an all-optical vector magnetometer enhanced by a machine learning model. Using a dual probing beam setup, spin projections in both probe directions are simultaneously detected. Vector information is directly obtained from the measured phases of spin projection signals. To enhance the measurement accuracy and mitigate the dead zone effect, we introduce an artificial neural network (ANN) to link the phase signals to the field direction. With the addition of amplitude information to the ANN input, the average angle error is reduced to less than 0.3° within a hemisphere. Furthermore, this configuration demonstrates a field angle sensitivity of better than 30 μ rad/Hz1/2.

Applied Physics Letters•Sep 2, 2024•5 citations

Herriott-cavity-assisted all-optical atomic vector magnetometer

B. Cai, Chongyan Hao, Zheru Qiu +3 more

We report an all-optical atomic vector magnetometer using dual Bell-Bloom optical pumping beams in a Rb vapor cell. This vector magnetometer consists of two orthogonal optical pumping beams, with amplitude modulations at $^{85}\mathrm{Rb}$ and $^{87}\mathrm{Rb}$ Larmor frequencies, respectively. We simultaneously detect atomic signals excited by these two pumping beams using a single probe beam in the third direction, and extract the field orientation information using the phase delays between the modulated atomic signals and the driving beams. By adding a Herriott cavity inside the vapor cell, we improve the magnetometer sensitivity. We study the performance of this vector magnetometer in a magnetic field ranging from 100 mG to 500 mG, and demonstrate a field angle sensitivity better than 10 $\ensuremath{\mu}\mathrm{rad}/{\mathrm{Hz}}^{1/2}$ above 10 Hz.

arXiv:2005.11196•Physical Review A•May 28, 2020•35 citations

Bell–Bloom magnetometer based on square optical path

Weipeng Li, Yue Chang, Xiaonan Zhang +3 more

We present a single-beam Bell-Bloom magnetometer using a compact, square optical path in a vapor cell with intensity modulation of the light beam. This design achieves dead-zone-free three-axis magnetic field measurements and, additionally, can determine the magnitude and direction of the magnetic field gradient. Experimental results demonstrate the dead-zone-free operation, with sensitivity in each axis scaling with the effective optical path length along that direction. Strong magnetic field gradients induce distinct resonance peak splitting, whereby the splitting width is proportional to the gradient magnitude. By applying a reference gradient, the system can infer the direction of an external gradient, effectively functioning as a dual-axis gradiometer. Rotating the vapor cell allows optimization of the optical path to minimize gradient-induced measurement distortions by aligning it perpendicular to the gradient direction.

Optics Express•Jul 18, 2025•1 citation

Machine learning assisted vector atomic magnetometry

Xin Meng, Youwei Zhang, Xichang Zhang +6 more

Multiparameter sensing such as vector magnetometry often involves complex setups due to various external fields needed in explicitly connecting one measured signal to one parameter. Here, we propose a paradigm of indirect encoding for vector atomic magnetometry based on machine learning. We encode the three-dimensional magnetic-field information in the set of four simultaneously acquired signals associated with the optical rotation of a laser beam traversing the atomic sample. The map between the recorded signals and the vectorial field information is established through a pre-trained deep neural network. We demonstrate experimentally a single-shot all optical vector atomic magnetometer, with a simple scalar-magnetometer design employing only one elliptically-polarized laser beam and no additional coils. Magnetic field amplitude sensitivities of about 100 [Formula: see text] and angular sensitivities of about [Formula: see text] (for a magnetic field of around 140 nT) are derived from the neural network. Our approach can reduce the complexity of the architecture of vector magnetometers, and may shed light on the general design of multiparameter sensing.

arXiv:2301.05707•Nature Communications•Sep 29, 2023•50 citations

Vector measurements using all optical scalar atomic magnetometers

Rui Zhang, Rahul R. Mhaskar, Ken A. Smith +2 more

Vector field measurement is demonstrated with an all-optical scalar atomic magnetometer using intrinsic parameters related to its scalar operation. The Bell-Bloom type atomic magnetometer measures the Larmor precession of cesium atoms through on-resonant absorption of a probe beam. While the AC component of the probe signal is used for the field magnitude measurement, the probe DC signal contains information about the polar angle, defined as the angle between the magnetic field and the probe beam. Additional polar angle information is obtained from the light-shift-induced magnetic field caused by the frequency modulation of the probe beam. With a measurement time of 100 ms, better than 0.02° sensitivity has been achieved using a commercial miniaturized sensor at the optimal sensor orientation. The angle measurement accuracy is checked against an optical encoder over the entire polar angle range of 0°–180°. Better than 1° error is recorded over most set polar angles. Azimuthal angle measurement is also exhibited with two orthogonally oriented sensors.

arXiv:2011.08943•Journal of Applied Physics•Jan 28, 2021•17 citations

A dead-zone free 4He atomic magnetometer with intensity-modulated linearly polarized light and a liquid crystal polarization rotator

Teng Wu, Xiang Peng, Zaisheng Lin +1 more

We demonstrate an all-optical (4)He atomic magnetometer experimental scheme based on an original Bell-Bloom configuration. A single intensity-modulated linearly polarized laser beam is used both for generating spin polarization within a single (4)He vapor and probing the spin precessing under a static magnetic field. The transmitted light signal from the vapor is then phase-sensitively detected at the modulation frequency and its harmonics, which lead to the atomic magnetic resonance signals. Based on this structure, a liquid crystal is added in our magnetometer system and constitutes a polarization rotator. By controlling the voltage applied on the liquid crystal, the light linear polarization vector can be kept perpendicular with the ambient magnetic field direction, which in turn provides the maximum resonance signal amplitude. Moreover, the system exhibits a magnetic-field noise floor of about 2pT/√Hz, which is not degraded due to the presence of the liquid crystal and varying magnetic field direction. The experiment results prove that our method can eliminate the dead-zone effect, improve the system spatial isotropy, and thus be suitable in mobile applications.

Review of Scientific Instruments•Oct 1, 2015•25 citations
This paper reports an all-optical vectorial operation method of a Bell-Bloom magnetometer. The spin projections in x and y axes are detected simultaneously by the dual probing beams configuration. And the vector information can be extracted from the phases of spin projection signals. By introducing an artificial neural network (ANN) to establish the relationship between signals and field direction, the phase errors are corrected automatically. With the assistance of ANN, the accuracy of the system has been greatly improved and dead zones have been eliminated basically.
This paper reports an all-optical vector magnetometer enhanced by a machine learning model. Using a dual probing beam setup, spin projections in both probe directions are simultaneously detected. Vector information is directly obtained from the measured phases of spin projection signals. To enhance the measurement accuracy and mitigate the dead zone effect, we introduce an artificial neural network (ANN) to link the phase signals to the field direction. With the addition of amplitude information to the ANN input, the average angle error is reduced to less than 0.3° within a hemisphere. Furthermore, this configuration demonstrates a field angle sensitivity of better than 30 μ rad/Hz1/2.
We report an all-optical atomic vector magnetometer using dual Bell-Bloom optical pumping beams in a Rb vapor cell. This vector magnetometer consists of two orthogonal optical pumping beams, with amplitude modulations at 85Rb^{85}\mathrm{Rb}85Rb and 87Rb^{87}\mathrm{Rb}87Rb Larmor frequencies, respectively. We simultaneously detect atomic signals excited by these two pumping beams using a single probe beam in the third direction, and extract the field orientation information using the phase delays between the modulated atomic signals and the driving beams. By adding a Herriott cavity inside the vapor cell, we improve the magnetometer sensitivity. We study the performance of this vector magnetometer in a magnetic field ranging from 100 mG to 500 mG, and demonstrate a field angle sensitivity better than 10 $\ensuremath{\mu}\mathrm{rad}/{\mathrm{Hz}}^{1/2}$ above 10 Hz.
We present a single-beam Bell-Bloom magnetometer using a compact, square optical path in a vapor cell with intensity modulation of the light beam. This design achieves dead-zone-free three-axis magnetic field measurements and, additionally, can determine the magnitude and direction of the magnetic field gradient. Experimental results demonstrate the dead-zone-free operation, with sensitivity in each axis scaling with the effective optical path length along that direction. Strong magnetic field gradients induce distinct resonance peak splitting, whereby the splitting width is proportional to the gradient magnitude. By applying a reference gradient, the system can infer the direction of an external gradient, effectively functioning as a dual-axis gradiometer. Rotating the vapor cell allows optimization of the optical path to minimize gradient-induced measurement distortions by aligning it perpendicular to the gradient direction.
Multiparameter sensing such as vector magnetometry often involves complex setups due to various external fields needed in explicitly connecting one measured signal to one parameter. Here, we propose a paradigm of indirect encoding for vector atomic magnetometry based on machine learning. We encode the three-dimensional magnetic-field information in the set of four simultaneously acquired signals associated with the optical rotation of a laser beam traversing the atomic sample. The map between the recorded signals and the vectorial field information is established through a pre-trained deep neural network. We demonstrate experimentally a single-shot all optical vector atomic magnetometer, with a simple scalar-magnetometer design employing only one elliptically-polarized laser beam and no additional coils. Magnetic field amplitude sensitivities of about 100 [Formula: see text] and angular sensitivities of about [Formula: see text] (for a magnetic field of around 140 nT) are derived from the neural network. Our approach can reduce the complexity of the architecture of vector magnetometers, and may shed light on the general design of multiparameter sensing.
Vector field measurement is demonstrated with an all-optical scalar atomic magnetometer using intrinsic parameters related to its scalar operation. The Bell-Bloom type atomic magnetometer measures the Larmor precession of cesium atoms through on-resonant absorption of a probe beam. While the AC component of the probe signal is used for the field magnitude measurement, the probe DC signal contains information about the polar angle, defined as the angle between the magnetic field and the probe beam. Additional polar angle information is obtained from the light-shift-induced magnetic field caused by the frequency modulation of the probe beam. With a measurement time of 100 ms, better than 0.02° sensitivity has been achieved using a commercial miniaturized sensor at the optimal sensor orientation. The angle measurement accuracy is checked against an optical encoder over the entire polar angle range of 0°–180°. Better than 1° error is recorded over most set polar angles. Azimuthal angle measurement is also exhibited with two orthogonally oriented sensors.
We demonstrate an all-optical (4)He atomic magnetometer experimental scheme based on an original Bell-Bloom configuration. A single intensity-modulated linearly polarized laser beam is used both for generating spin polarization within a single (4)He vapor and probing the spin precessing under a static magnetic field. The transmitted light signal from the vapor is then phase-sensitively detected at the modulation frequency and its harmonics, which lead to the atomic magnetic resonance signals. Based on this structure, a liquid crystal is added in our magnetometer system and constitutes a polarization rotator. By controlling the voltage applied on the liquid crystal, the light linear polarization vector can be kept perpendicular with the ambient magnetic field direction, which in turn provides the maximum resonance signal amplitude. Moreover, the system exhibits a magnetic-field noise floor of about 2pT/√Hz, which is not degraded due to the presence of the liquid crystal and varying magnetic field direction. The experiment results prove that our method can eliminate the dead-zone effect, improve the system spatial isotropy, and thus be suitable in mobile applications.