Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Express

Bell–Bloom magnetometer based on square optical path

Weipeng Li, Yue Chang, Xiaonan Zhang, Wenhao Luo, Xiaogang Wei, Renfu Yang

Published Jul 18, 2025• 1 citation
Publisher

Abstract

We present a single-beam Bell-Bloom magnetometer using a compact, square optical path in a vapor cell with intensity modulation of the light beam. This design achieves dead-zone-free three-axis magnetic field measurements and, additionally, can determine the magnitude and direction of the magnetic field gradient. Experimental results demonstrate the dead-zone-free operation, with sensitivity in each axis scaling with the effective optical path length along that direction. Strong magnetic field gradients induce distinct resonance peak splitting, whereby the splitting width is proportional to the gradient magnitude. By applying a reference gradient, the system can infer the direction of an external gradient, effectively functioning as a dual-axis gradiometer. Rotating the vapor cell allows optimization of the optical path to minimize gradient-induced measurement distortions by aligning it perpendicular to the gradient direction.

DOI
10.1364/oe.566844

Related papers

Dead-zone-free free-induction-decay alkali-metal atomic magnetometer

X.-K. Wang, J. He, HH Deng +2 more

The detection dead zone is an important systematic limitation in scalar atomic magnetometers, constraining their practical utility. In this work, we demonstrate a sensitive dead zone free scalar magnetometer by integrating previously established techniques into a FID magnetometer based on Bell Bloom optical pumping. The dead zone is eliminated by inserting a reflecting mirror within a multipass cavity assisted atomic cell, which folds the optical beam into orthogonal paths. Our analysis reveals that interregion cross talk is essential for interpreting the resulted experimental signals. The sensor exhibits oscillation signal amplitude variations within a factor of three across all orientations in three dimensional space, and a field sensitivity better than 80 fT/Hz^(1/2) over the full space. We further characterize the heading error in the geomagnetic field range, where experimental results agree with theoretical predictions within 0.7 nT. Additionally, the sensor can operate in a closed loop mode by feeding back the real time frequency extracted from the FID signal to modulate the pump beam, we characterize the magnetic field slew rate of the sensor. This work paves the way towards a sensitive vector FID magnetometer.

arXiv:2609.04847•Physical Review A•Aug 25, 2026•0 citations

A dead-zone free 4He atomic magnetometer with intensity-modulated linearly polarized light and a liquid crystal polarization rotator

Teng Wu, Xiang Peng, Zaisheng Lin +1 more

We demonstrate an all-optical (4)He atomic magnetometer experimental scheme based on an original Bell-Bloom configuration. A single intensity-modulated linearly polarized laser beam is used both for generating spin polarization within a single (4)He vapor and probing the spin precessing under a static magnetic field. The transmitted light signal from the vapor is then phase-sensitively detected at the modulation frequency and its harmonics, which lead to the atomic magnetic resonance signals. Based on this structure, a liquid crystal is added in our magnetometer system and constitutes a polarization rotator. By controlling the voltage applied on the liquid crystal, the light linear polarization vector can be kept perpendicular with the ambient magnetic field direction, which in turn provides the maximum resonance signal amplitude. Moreover, the system exhibits a magnetic-field noise floor of about 2pT/√Hz, which is not degraded due to the presence of the liquid crystal and varying magnetic field direction. The experiment results prove that our method can eliminate the dead-zone effect, improve the system spatial isotropy, and thus be suitable in mobile applications.

Review of Scientific Instruments•Oct 1, 2015•25 citations

Polarization-gradient optical pumping in an atomic magnetometer

Xiaona Liu, Yujie Sun, Zhaoying Wang

High-precision Mz/Mx atomic magnetometers have “dead zones”, where the magnetic-field information will be lost because the light–atom interaction vanishes at specific field angles. To suppress dead zones, we propose a scheme with polarization-gradient optical pumping field by using counter-propagating lin⊥lin beams. We found through experiments that the lin⊥lin scheme eliminates dead zones in the transverse plane of the probe beam propagation (minimum ∼40% normalized signal) but leaves two noncanonical magic-angle-like directions (≈30 ∘ and 150 ∘ ) in the longitudinal plane, which is distinct from the standard tensor magic angle (≈54 ∘ and 126 ∘ ). These observations are quantitatively explained using a multipole-based model formulated in terms of an effective, spatially averaged density matrix, which is the first time that the spatial average density matrix has been used for energy state analysis in atomic magnetometers. Under the probing of a linearly polarized light, the measured signal is determined by the field-angle-dependent projection of the atomic longitudinal alignment moment ( m 2,0 ) onto the B 0 -defined quantization axis. Compared with other dead-zone elimination schemes, our scheme avoids polarization modulation and multi-cell architectures, showing potential for improving the spatial response range of compact atomic magnetometry.

Optics Letters•Apr 28, 2026•0 citations

Herriott-cavity-assisted all-optical atomic vector magnetometer

B. Cai, Chongyan Hao, Zheru Qiu +3 more

We report an all-optical atomic vector magnetometer using dual Bell-Bloom optical pumping beams in a Rb vapor cell. This vector magnetometer consists of two orthogonal optical pumping beams, with amplitude modulations at $^{85}\mathrm{Rb}$ and $^{87}\mathrm{Rb}$ Larmor frequencies, respectively. We simultaneously detect atomic signals excited by these two pumping beams using a single probe beam in the third direction, and extract the field orientation information using the phase delays between the modulated atomic signals and the driving beams. By adding a Herriott cavity inside the vapor cell, we improve the magnetometer sensitivity. We study the performance of this vector magnetometer in a magnetic field ranging from 100 mG to 500 mG, and demonstrate a field angle sensitivity better than 10 $\ensuremath{\mu}\mathrm{rad}/{\mathrm{Hz}}^{1/2}$ above 10 Hz.

arXiv:2005.11196•Physical Review A•May 28, 2020•35 citations

Dead-zone free multi-beam atomic sensor for 4He magnetometer

Wei Gong, Haidong Wang, Teng Wu +5 more

A multi-beam atomic sensor with three orthogonal helium vapor cells to guarantee the availability of4He magnetometer under different directions of magnetic field is proposed and tested, which demonstrates experimentally that dead zones of magnetic field measurement can be eliminated. Furthermore, with the special optical design, the multi-beam atomic sensor is also used for laser frequency stabilization simultaneously, which shows the possibility of reducing heading errors caused by the light shift effect.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 1, 2016•2 citations

An Integrated Single-Beam Three-Axis High-Sensitivity Magnetometer

Shengran Su, Zhen-Yuan Xu, Xiang He +6 more

Three-axis atomic magnetometers have great advantages for interpreting information conveyed by magnetic fields. Here, we demonstrate a compact construction of a three-axis vector atomic magnetometer. The magnetometer is operated with a single laser beam and with a specially designed triangular 87Rb vapor cell (side length is 5 mm). The ability of three-axis measurement is realized by reflecting the light beam in the cell chamber under high pressure, so that the atoms before and after reflection are polarized along two different directions. It achieves a sensitivity of 40 fT/Hz in x-axis, 20 fT/Hz in y-axis, and 30 fT/Hz in z-axis under spin-exchange relaxation-free regime. The crosstalk effect between different axes is proven to be little in this configuration. The sensor configuration here is expected to form further values, especially for vector biomagnetism measurement, clinical diagnosis, and field source reconstruction.

Sensors•Mar 15, 2023•16 citations
We present a single-beam Bell-Bloom magnetometer using a compact, square optical path in a vapor cell with intensity modulation of the light beam. This design achieves dead-zone-free three-axis magnetic field measurements and, additionally, can determine the magnitude and direction of the magnetic field gradient. Experimental results demonstrate the dead-zone-free operation, with sensitivity in each axis scaling with the effective optical path length along that direction. Strong magnetic field gradients induce distinct resonance peak splitting, whereby the splitting width is proportional to the gradient magnitude. By applying a reference gradient, the system can infer the direction of an external gradient, effectively functioning as a dual-axis gradiometer. Rotating the vapor cell allows optimization of the optical path to minimize gradient-induced measurement distortions by aligning it perpendicular to the gradient direction.
The detection dead zone is an important systematic limitation in scalar atomic magnetometers, constraining their practical utility. In this work, we demonstrate a sensitive dead zone free scalar magnetometer by integrating previously established techniques into a FID magnetometer based on Bell Bloom optical pumping. The dead zone is eliminated by inserting a reflecting mirror within a multipass cavity assisted atomic cell, which folds the optical beam into orthogonal paths. Our analysis reveals that interregion cross talk is essential for interpreting the resulted experimental signals. The sensor exhibits oscillation signal amplitude variations within a factor of three across all orientations in three dimensional space, and a field sensitivity better than 80 fT/Hz^(1/2) over the full space. We further characterize the heading error in the geomagnetic field range, where experimental results agree with theoretical predictions within 0.7 nT. Additionally, the sensor can operate in a closed loop mode by feeding back the real time frequency extracted from the FID signal to modulate the pump beam, we characterize the magnetic field slew rate of the sensor. This work paves the way towards a sensitive vector FID magnetometer.
We demonstrate an all-optical (4)He atomic magnetometer experimental scheme based on an original Bell-Bloom configuration. A single intensity-modulated linearly polarized laser beam is used both for generating spin polarization within a single (4)He vapor and probing the spin precessing under a static magnetic field. The transmitted light signal from the vapor is then phase-sensitively detected at the modulation frequency and its harmonics, which lead to the atomic magnetic resonance signals. Based on this structure, a liquid crystal is added in our magnetometer system and constitutes a polarization rotator. By controlling the voltage applied on the liquid crystal, the light linear polarization vector can be kept perpendicular with the ambient magnetic field direction, which in turn provides the maximum resonance signal amplitude. Moreover, the system exhibits a magnetic-field noise floor of about 2pT/√Hz, which is not degraded due to the presence of the liquid crystal and varying magnetic field direction. The experiment results prove that our method can eliminate the dead-zone effect, improve the system spatial isotropy, and thus be suitable in mobile applications.
High-precision Mz/Mx atomic magnetometers have “dead zones”, where the magnetic-field information will be lost because the light–atom interaction vanishes at specific field angles. To suppress dead zones, we propose a scheme with polarization-gradient optical pumping field by using counter-propagating lin⊥lin beams. We found through experiments that the lin⊥lin scheme eliminates dead zones in the transverse plane of the probe beam propagation (minimum ∼40% normalized signal) but leaves two noncanonical magic-angle-like directions (≈30 ∘ and 150 ∘ ) in the longitudinal plane, which is distinct from the standard tensor magic angle (≈54 ∘ and 126 ∘ ). These observations are quantitatively explained using a multipole-based model formulated in terms of an effective, spatially averaged density matrix, which is the first time that the spatial average density matrix has been used for energy state analysis in atomic magnetometers. Under the probing of a linearly polarized light, the measured signal is determined by the field-angle-dependent projection of the atomic longitudinal alignment moment ( m 2,0 ) onto the B 0 -defined quantization axis. Compared with other dead-zone elimination schemes, our scheme avoids polarization modulation and multi-cell architectures, showing potential for improving the spatial response range of compact atomic magnetometry.
We report an all-optical atomic vector magnetometer using dual Bell-Bloom optical pumping beams in a Rb vapor cell. This vector magnetometer consists of two orthogonal optical pumping beams, with amplitude modulations at 85Rb^{85}\mathrm{Rb}85Rb and 87Rb^{87}\mathrm{Rb}87Rb Larmor frequencies, respectively. We simultaneously detect atomic signals excited by these two pumping beams using a single probe beam in the third direction, and extract the field orientation information using the phase delays between the modulated atomic signals and the driving beams. By adding a Herriott cavity inside the vapor cell, we improve the magnetometer sensitivity. We study the performance of this vector magnetometer in a magnetic field ranging from 100 mG to 500 mG, and demonstrate a field angle sensitivity better than 10 $\ensuremath{\mu}\mathrm{rad}/{\mathrm{Hz}}^{1/2}$ above 10 Hz.
A multi-beam atomic sensor with three orthogonal helium vapor cells to guarantee the availability of4He magnetometer under different directions of magnetic field is proposed and tested, which demonstrates experimentally that dead zones of magnetic field measurement can be eliminated. Furthermore, with the special optical design, the multi-beam atomic sensor is also used for laser frequency stabilization simultaneously, which shows the possibility of reducing heading errors caused by the light shift effect.
Three-axis atomic magnetometers have great advantages for interpreting information conveyed by magnetic fields. Here, we demonstrate a compact construction of a three-axis vector atomic magnetometer. The magnetometer is operated with a single laser beam and with a specially designed triangular 87Rb vapor cell (side length is 5 mm). The ability of three-axis measurement is realized by reflecting the light beam in the cell chamber under high pressure, so that the atoms before and after reflection are polarized along two different directions. It achieves a sensitivity of 40 fT/Hz in x-axis, 20 fT/Hz in y-axis, and 30 fT/Hz in z-axis under spin-exchange relaxation-free regime. The crosstalk effect between different axes is proven to be little in this configuration. The sensor configuration here is expected to form further values, especially for vector biomagnetism measurement, clinical diagnosis, and field source reconstruction.