Applied Physics Letters

Determination of the ground-state hyperfine splitting of trapped 171Yb+ ions

J. Z. Han, N. C. Xin, J. W. Zhang, Yanmei Yu, Jiguang Li, L. Qian, L. J. Wang

Published Aug 19, 2024• 6 citations
Publisher

Abstract

We present the determination of the ground-state hyperfine splitting (νHFS) in laser-cooled 171Yb+ ions using our microwave quantum frequency standard (QFS). Employing Ramsey spectroscopy in a closed-loop measurement configuration, we have achieved a νHFS value of 12 642 812 118 469.0(8) mHz with a fractional uncertainty of 6.6×10−14. This result aligns with previously reported values and represents the highest accuracy reported to date for such measurements conducted in a single-shot closed-loop configuration, without averaging over multiple dates. The development of this accurate 171Yb+ microwave QFS holds promise as a transportable time-frequency reference for satellite navigation systems.

DOI
10.1063/5.0226908

Related papers

Precision determination of the ground-state hyperfine splitting of trapped 113Cd+ ions

S. N. Miao, Jianwei Zhang, H. R. Qin +3 more

We measured the ground-state hyperfine splitting of trapped 113 C d + ions to be 15199862855.02799(27) Hz with a fractional uncertainty of 1.8 × 10 − 14 . The ions were trapped and laser-cooled in a linear quadrupole Paul trap. The fractional frequency stability was measured to be 4.2 × 10 − 13 / τ , obtained from Ramsey fringes of high signal-to-noise ratios and taken over a measurement time of nearly 5 h, which is close to the short-term stability limit estimated from the Dick effect. Our result is consistent with previously reported values, but the measurement precision is four times better than the best result obtained to date.

Optics Letters•Nov 2, 2021•21 citations

A MICROWAVE FREQUENCY STANDARD BASED ON LASER-COOLED 171 Yb + IONS

Richard B. Warrington, Peter Fisk, Michael J. Wouters +1 more

We report the first operation of a microwave frequency standard based on the 12.6 GHz ground-state hyperfine transition in a cloud of laser-cooled 171 Yb + ions, with a preliminary measurement of the transition frequency. We obtain 12 642 812 118.468 5(7)(6) Hz, where the first uncertainty combines statistical uncertainty and the uncertainty of the systematic shifts in the transition frequency due to the trap environment, and the second is that of a comparison between a reference hydrogen maser and the SI second. This value is in agreement with earlier measurements obtained for buffer gas-cooled ions where the second-order Doppler shift is 180 times larger. A full evaluation of systematic shifts is still pending, but the dominant effects are discussed. Motional second-order Doppler shifts are determined within an uncertainty of 1–2 parts in 10 15 from measurements of the ion temperature. Our progress to date indicates no serious obstacle to realising a combined fractional frequency uncertainty of 4 × 10 -15 or smaller and a projected stability of approximately 5 × 10 -14 τ -1/2 for a 10 s Ramsey time. The performance of the 171 Yb + microwave standard can therefore be comparable to that of a cesium fountain.

Symposium on Frequency Standards and Metrology•May 1, 2002•11 citations

High-accuracy frequency standards using laser-cooled Hg+ ions

Dana J. Berkeland, J.D. Miller, Brent C. Young +3 more

We discuss frequency standards based on laser-cooled 199Hg+ ions confined in cryogenic rf traps. In one experiment, the frequency of a microwave source is served to the ions' ground-state hyperfine transition at 40.5 GHz. For seven ions and a Ramsey free precession time of 100 s, the fractional frequency stability is 3.3 (2) X 10-13 (tau) -1/2 for measurement times (tau) < 2 h. The ground-state hyperfine interval is measured to be 40 507 347 996.841 59 (14) (41) Hz, where the first number in parentheses is the uncertainty due to statistics and systematic errors, and the second is the uncertainty in the frequency of the time scale to which the standard is compared. In a second experiment under development, a strong-binding cryogenic trap will confine a single ion used for an optical frequency standard based on a narrow electric quadrupole transition at 282 nm. The bandwidth of the laser used to drive this transition is less than 10 Hz at 563 nm.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•May 15, 1998•1 citation

A Microwave Clock Based on Laser-Cooled 171 Yb + Ions

N. C. Xin, Jianwei Zhang, S. N. Miao +5 more

A microwave frequency standard based on laser-cooled171Yb+ions at Tsinghua University has been investigated. More than 105171Yb+ions were stably trapped for over 40 hours. The ground-state hyperfine splitting frequency of171Yb+was determined to be 12642812118.4672(8) Hz with a fractional frequency uncertainty of 6.33×10−14. Our work is in a continuous line with that of other scholars.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 24, 2022•2 citations

Laser-cooled 171Yb+ microwave frequency standard with a short-term frequency instability of 8.5 × 10−13/√τ

N. C. Xin, H. R. Qin, S. N. Miao +5 more

We report on the development of a microwave frequency standard based on a laser-cooled 171 Y b + ion trap system. The electronics , lasers, and magnetic shields are integrated into a single physical package. With over 105 ions are stably trapped, the system offers a high signal-to-noise ratio Ramsey line-shape. In comparison with previous work, the frequency instability of a 171 Y b + microwave clock was further improved to 8.5 × 10 − 13 / τ for averaging times between 10 and 1000 s. Essential systematic shifts and uncertainties are also estimated.

Optics Express•Mar 22, 2022•24 citations

High-accuracy measurement of the ^113Cd^+ ground-state hyperfine splitting at the milli-Hertz level

Shiguang Wang, Jianwei Zhang, K. Miao +2 more

We have developed a microwave frequency standard based on the 15.2 GHz ground-stated hyperfine transition of (113)C(+) ions. Using a laser-cooled ion cloud trapped in a linear quadrupole Paul trap, the clock transition frequency is measured to be 15 199 862 855.0125(87) Hz, with an accuracy at the 10(-13) level. The main errors are from the microwave frequency reference used in the experiment. The precision is improved by nearly two orders of magnitude than that reported before.

Optics Express•May 14, 2013•20 citations
We present the determination of the ground-state hyperfine splitting (νHFS) in laser-cooled 171Yb+ ions using our microwave quantum frequency standard (QFS). Employing Ramsey spectroscopy in a closed-loop measurement configuration, we have achieved a νHFS value of 12 642 812 118 469.0(8) mHz with a fractional uncertainty of 6.6×10−14. This result aligns with previously reported values and represents the highest accuracy reported to date for such measurements conducted in a single-shot closed-loop configuration, without averaging over multiple dates. The development of this accurate 171Yb+ microwave QFS holds promise as a transportable time-frequency reference for satellite navigation systems.
We measured the ground-state hyperfine splitting of trapped 113 C d + ions to be 15199862855.02799(27) Hz with a fractional uncertainty of 1.8 × 10 − 14 . The ions were trapped and laser-cooled in a linear quadrupole Paul trap. The fractional frequency stability was measured to be 4.2 × 10 − 13 / τ , obtained from Ramsey fringes of high signal-to-noise ratios and taken over a measurement time of nearly 5 h, which is close to the short-term stability limit estimated from the Dick effect. Our result is consistent with previously reported values, but the measurement precision is four times better than the best result obtained to date.
We report the first operation of a microwave frequency standard based on the 12.6 GHz ground-state hyperfine transition in a cloud of laser-cooled 171 Yb + ions, with a preliminary measurement of the transition frequency. We obtain 12 642 812 118.468 5(7)(6) Hz, where the first uncertainty combines statistical uncertainty and the uncertainty of the systematic shifts in the transition frequency due to the trap environment, and the second is that of a comparison between a reference hydrogen maser and the SI second. This value is in agreement with earlier measurements obtained for buffer gas-cooled ions where the second-order Doppler shift is 180 times larger. A full evaluation of systematic shifts is still pending, but the dominant effects are discussed. Motional second-order Doppler shifts are determined within an uncertainty of 1–2 parts in 10 15 from measurements of the ion temperature. Our progress to date indicates no serious obstacle to realising a combined fractional frequency uncertainty of 4 × 10 -15 or smaller and a projected stability of approximately 5 × 10 -14 τ -1/2 for a 10 s Ramsey time. The performance of the 171 Yb + microwave standard can therefore be comparable to that of a cesium fountain.
We discuss frequency standards based on laser-cooled 199Hg+ ions confined in cryogenic rf traps. In one experiment, the frequency of a microwave source is served to the ions' ground-state hyperfine transition at 40.5 GHz. For seven ions and a Ramsey free precession time of 100 s, the fractional frequency stability is 3.3 (2) X 10-13 (tau) -1/2 for measurement times (tau) < 2 h. The ground-state hyperfine interval is measured to be 40 507 347 996.841 59 (14) (41) Hz, where the first number in parentheses is the uncertainty due to statistics and systematic errors, and the second is the uncertainty in the frequency of the time scale to which the standard is compared. In a second experiment under development, a strong-binding cryogenic trap will confine a single ion used for an optical frequency standard based on a narrow electric quadrupole transition at 282 nm. The bandwidth of the laser used to drive this transition is less than 10 Hz at 563 nm.
We report on the development of a microwave frequency standard based on a laser-cooled 171 Y b + ion trap system. The electronics , lasers, and magnetic shields are integrated into a single physical package. With over 105 ions are stably trapped, the system offers a high signal-to-noise ratio Ramsey line-shape. In comparison with previous work, the frequency instability of a 171 Y b + microwave clock was further improved to 8.5 × 10 − 13 / τ for averaging times between 10 and 1000 s. Essential systematic shifts and uncertainties are also estimated.