Journal of Physics Conference Series

Developments to improve the stability of optical lattice clocks

S. Bize, Bess Fang, Yann Le Coq, Rodolphe Le Targat, Jérôme Lodewyck, Paul-Éric Pottie, H. Shang, Clara Zyskind

Published Nov 1, 2024• 1 citation
Publisher

Abstract

Abstract We present several developments aimed at improving the stability of optical lattice clocks. First, we present our developments of an optical lattice clock using neutral mercury. We mention recent advances made with the fermionic isotope 199Hg. We also mention our work aimed at using bosonic isotopes, which offer the possibility to circumvent the relatively short lifetime of the upper clock state in 199Hg. Second, we present our work on a non-destructive detection in a Sr optical lattice clock. We describe developments that brought the detection scheme from the classical non-destructive regime to the quantum non-destructive regime. Our detection scheme is practical and has the capability to the used beyond proving the principle. Finally, we present our work on laser stabilization using spectral hole burning in a Eu3+:Y2SiO5 crystal at cryogenic temperatures. We describe our development of low noise interrogation based on digital IQ modulation and detection that can probe multiple spectral features simultaneously, as well as several investigations towards fluctuating environmental factors. These advances, individually or combined for example with spectral purity transfer with combs and composite clock approaches, shall bring significant progress in clock stability and accuracy.

DOI
10.1088/1742-6596/2889/1/012048

Related papers

A High-Performance Optical Lattice Clock Based On Bosonic Atoms

S. Origlia, M.S. Pramod

Optical lattice clocks with uncertainty and instability in the 10􀀀17-range and below have so far been demonstrated exclusively using fermions. Here, we demonstrate a bosonic optical lattice clock with 3 10􀀀18 instability and 2:0 10􀀀17 accuracy, both values improving on previous work by a factor 30. This was enabled by probing the clock transition with an ultra-long interrogation time of 4 s, using the long coherence time provided by a cryogenic silicon resonator, by careful stabilization of relevant operating parameters, and by operating at low atom density. This work demonstrates that bosonic clocks, in combination with highly coherent interrogation lasers, are suitable for highaccuracy applications with particular requirements, such as high reliability, transportability, operation in space, or suitability for particular fundamental physics topics. As an example, we determine the 88Sr { 87Sr isotope shift with 12 mHz uncertainty.

•Feb 24, 2018•1 citation

Recent progress of neutral mercury lattice clock in SIOM

X H Fu, S Fang, R C Zhao +3 more

The optical lattice clock develops fast in recent years, and its stability and accuracy has already surpassed the microwave fountain clock and the optical clock based on ion trap. The mercury (Hg) lattice clock has the possibility to make a breakthrough in the limitation of blackbody radiation shift for strontium (Sr) and ytterbium (Yb) lattice clock, and reach the uncertainty in E-18 level at room temperature. For the purposes of laser cooling of mercury atoms and interrogating of the clock transition from1S0state to3P0state, a high-power cooling laser at 253.7 nm and an ultra-stable Hz-level linewidth laser at 265.6 nm are required, respectively. Here, we report our development of these laser sources for a neutral Hg lattice clock.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 1, 2017•0 citations

OPTICAL LATTICE CLOCK WITH Sr ATOMS

Philip G. Westergaard, Arnaud Lecallier, Jérôme Lodewyck +1 more

We review the recent progress at LNE-SYRTE on an optical lattice clock using Sr atoms. We discuss the required lattice depth to cancel motional effects in such a clock and show that a relatively small lattice depth is sufficient provided the lattice is oriented vertically. We also demonstrate an accurate frequency measurement of the Sr clock transition with accuracy in the low 10 -15 range. Finally, we describe a new non-destructive method to detect the atoms in the clock and discuss the expected associated improvement in the frequency stability of the clock.

Symposium on Frequency Standards and Metrology•May 1, 2009•0 citations

Frequency stability of optical lattice clocks

Jérôme Lodewyck, Philip G. Westergaard, Arnaud Lecallier +2 more

In this paper, we review several aspects of the frequency stability of optical lattice clocks. We describe a new ultra-stable cavity design with reduced thermal noise and record frequency stability (below 10 −15 ), as well as a non-destructive detection scheme for measuring the clock transition probability. Given the experimental parameters we measured, we simulate different sequence strategies for optimizing the stability. Finally, we report on the development of a second optical lattice clock and simulate several comparison strategies. In particular, we show by a numerical method that a stability as low as 2 × 10 −16 τ −1/2 can be reached with optical lattice clocks, and we show how to demonstrate this stability with a double clock system.

New Journal of Physics•Jun 28, 2010•33 citations

OPTICAL LATTICE CLOCK: SEVEN YEARS OF PROGRESS AND NEXT STEPS

Hidetoshi Katori, Masao Takamoto, Tomoya Akatsuka

We discuss configurations of optical lattice clocks from the viewpoint of lattice geometries and quantum statistics of interrogated atoms. This leads to two promising schemes: a one-dimensional lattice loaded with spin-polarized fermions and a three-dimensional lattice loaded with bosons. These two optical lattice clocks based on fermionic 87 Sr and bosonic 88 Sr were demonstrated by measuring the frequency stability as well as their isotope shift. In addition, we address the ongoing experimental challenges for optical lattice clocks.

Symposium on Frequency Standards and Metrology•May 1, 2009•0 citations

Towards the Development of an Optical Lattice Clock Using Bosonic Isotopes of Mercury

Clara Zyskind, M. Andia, Changlei Guo +1 more

In this poster, we will describe the key developments made in our setup to switch from a clock using fermionic isotopes of mercury to bosonic isotopes of mercury. Initially, we must establish the magnetic field necessary for the quenching method, i.e. to induce the bosonic clock transition. We have introduced a technique to create a strong magnetic field during the probing time. Furthermore, we have enhanced our control over the magnetic environment. Secondly, as we aim to observe the clock transition, we have had to enhance the capabilities of our ultrastable light generation. This enhancement was crucial to provide a tuning range sufficient to reach the frequency of any of the five stable bosonic isotopes while maintaining spectral quality. Thirdly, we calculated the theoretical Rabi pulsation for a clock utilizing bosonic isotopes, determining that we must increase the the probe laser power to achieve a sufficiently large Rabi pulsation. This adjustment is necessary to facilitate the initial exploration of the transition.

•Nov 26, 2021•0 citations
Abstract We present several developments aimed at improving the stability of optical lattice clocks. First, we present our developments of an optical lattice clock using neutral mercury. We mention recent advances made with the fermionic isotope 199Hg. We also mention our work aimed at using bosonic isotopes, which offer the possibility to circumvent the relatively short lifetime of the upper clock state in 199Hg. Second, we present our work on a non-destructive detection in a Sr optical lattice clock. We describe developments that brought the detection scheme from the classical non-destructive regime to the quantum non-destructive regime. Our detection scheme is practical and has the capability to the used beyond proving the principle. Finally, we present our work on laser stabilization using spectral hole burning in a Eu3+:Y2SiO5 crystal at cryogenic temperatures. We describe our development of low noise interrogation based on digital IQ modulation and detection that can probe multiple spectral features simultaneously, as well as several investigations towards fluctuating environmental factors. These advances, individually or combined for example with spectral purity transfer with combs and composite clock approaches, shall bring significant progress in clock stability and accuracy.
Optical lattice clocks with uncertainty and instability in the 10􀀀17-range and below have so far been demonstrated exclusively using fermions. Here, we demonstrate a bosonic optical lattice clock with 3 10􀀀18 instability and 2:0 10􀀀17 accuracy, both values improving on previous work by a factor 30. This was enabled by probing the clock transition with an ultra-long interrogation time of 4 s, using the long coherence time provided by a cryogenic silicon resonator, by careful stabilization of relevant operating parameters, and by operating at low atom density. This work demonstrates that bosonic clocks, in combination with highly coherent interrogation lasers, are suitable for highaccuracy applications with particular requirements, such as high reliability, transportability, operation in space, or suitability for particular fundamental physics topics. As an example, we determine the 88Sr { 87Sr isotope shift with 12 mHz uncertainty.
The optical lattice clock develops fast in recent years, and its stability and accuracy has already surpassed the microwave fountain clock and the optical clock based on ion trap. The mercury (Hg) lattice clock has the possibility to make a breakthrough in the limitation of blackbody radiation shift for strontium (Sr) and ytterbium (Yb) lattice clock, and reach the uncertainty in E-18 level at room temperature. For the purposes of laser cooling of mercury atoms and interrogating of the clock transition from1S0state to3P0state, a high-power cooling laser at 253.7 nm and an ultra-stable Hz-level linewidth laser at 265.6 nm are required, respectively. Here, we report our development of these laser sources for a neutral Hg lattice clock.
We review the recent progress at LNE-SYRTE on an optical lattice clock using Sr atoms. We discuss the required lattice depth to cancel motional effects in such a clock and show that a relatively small lattice depth is sufficient provided the lattice is oriented vertically. We also demonstrate an accurate frequency measurement of the Sr clock transition with accuracy in the low 10 -15 range. Finally, we describe a new non-destructive method to detect the atoms in the clock and discuss the expected associated improvement in the frequency stability of the clock.
In this paper, we review several aspects of the frequency stability of optical lattice clocks. We describe a new ultra-stable cavity design with reduced thermal noise and record frequency stability (below 10 −15 ), as well as a non-destructive detection scheme for measuring the clock transition probability. Given the experimental parameters we measured, we simulate different sequence strategies for optimizing the stability. Finally, we report on the development of a second optical lattice clock and simulate several comparison strategies. In particular, we show by a numerical method that a stability as low as 2 × 10 −16 τ −1/2 can be reached with optical lattice clocks, and we show how to demonstrate this stability with a double clock system.
We discuss configurations of optical lattice clocks from the viewpoint of lattice geometries and quantum statistics of interrogated atoms. This leads to two promising schemes: a one-dimensional lattice loaded with spin-polarized fermions and a three-dimensional lattice loaded with bosons. These two optical lattice clocks based on fermionic 87 Sr and bosonic 88 Sr were demonstrated by measuring the frequency stability as well as their isotope shift. In addition, we address the ongoing experimental challenges for optical lattice clocks.
In this poster, we will describe the key developments made in our setup to switch from a clock using fermionic isotopes of mercury to bosonic isotopes of mercury. Initially, we must establish the magnetic field necessary for the quenching method, i.e. to induce the bosonic clock transition. We have introduced a technique to create a strong magnetic field during the probing time. Furthermore, we have enhanced our control over the magnetic environment. Secondly, as we aim to observe the clock transition, we have had to enhance the capabilities of our ultrastable light generation. This enhancement was crucial to provide a tuning range sufficient to reach the frequency of any of the five stable bosonic isotopes while maintaining spectral quality. Thirdly, we calculated the theoretical Rabi pulsation for a clock utilizing bosonic isotopes, determining that we must increase the the probe laser power to achieve a sufficiently large Rabi pulsation. This adjustment is necessary to facilitate the initial exploration of the transition.