Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optical and Quantum Sensing and Precision Metrology II

Proposal for a very tall atom interferometer

Frank A. Narducci

Published Mar 12, 2024• 0 citations
Publisher
DOI
10.1117/12.3016089

Related papers

Novel atom interferometers

Frank A. Narducci

Optical and Quantum Sensing and Precision Metrology II•Mar 5, 2026•0 citations

Progress toward large-area strontium atom interferometry for precision gravitational measurements

Tim Kovachy

Atom interferometers in which atoms are delocalized over macroscopic distances can provide excellent sensitivity for gravitational measurements. I will describe progress on the design and construction of a two-meter-tall strontium atomic fountain that aims to leverage such atom interferometers to search for new interactions beyond the standard model via tests of the gravitational inverse square law and to make a new measurement of Newton’s gravitational constant. Moreover, I will discuss progress on MAGIS-100, a 100-meter-tall atom interferometer being built at Fermilab to serve as a prototype gravitational wave detector in the 0.3 – 3 Hz range and to search for ultralight dark matter.

Optical and Quantum Sensing and Precision Metrology•Mar 4, 2021•0 citations

A More Precise Atom Interferometer

Anonymous

Physics•Mar 12, 2020•0 citations

Macroscopic scale atom interferometers: introduction, techniques, and applications

Tim Kovachy, Alex Sugarbaker, Remy Notermans +4 more

This chapter introduces the fundamental principles and some of the applications of light-pulse atom interferometry. It includes tutorials on various atom optics techniques and on interferometer phase shift calculations. Recent advances in large momentum transfer atom optics and in the generation and manipulation of ultra-low-velocity-spread atom clouds have enabled atom interferometers that cover macroscopic scales in space (tens of centimeters) and in time (multiple seconds), dramatically improving interferometer sensitivity in a wide range of applications. This chapter reviews these advances and recent experiments performed with macroscopic scale atom interferometers in the 10-meter-tall atomic fountain at Stanford.

Oxford University Press eBooks•May 16, 2019•2 citations

Laser system for the 100-meter-tall MAGIS-100 atom interferometer

Kenneth DeRose

MAGIS-100 is a 100-meter atom interferometer currently being built at Fermilab and will be the worlds largest atom fountain. It will leverage modern atom optics techniques to search for dark matter, perform quantum atomic experiments, and detect gravitational waves at frequencies inaccessible to LIGO and LISA. Generation and precise control of meter-separated quantum atomic superpositions within the interferometer requires an agile laser system able to rapidly shift the optical frequency up to a rate of 100 GHz/s while maintaining a phase lock to our static frequency comb. To meet the power requirement of the experiment, the two interferometry lasers are coherently locked and must be robust to rapid frequency shifts. The interferometry laser's spatial mode is cleaned through fiber coupling and long free space propagation in vacuum with frequency noise introduced by the fiber suppressed by a PID lock. In addition to the scientific and technical hurdles in this experiment, there are complex laser safety issues. There are a total of twenty-four lasers and seven wavelengths ranging from 50mW to 100W, all within the same LCA.

International Laser Safety Conference (ILSC)•Mar 1, 2023•0 citations

Atom Interferometry Experiments in Fundamental Physics

Pei-Chen Kuan, Shau-Yu Lan, Brian Estey +2 more

Bulletin of the American Physical Society•May 26, 2010•0 citations
Atom interferometers in which atoms are delocalized over macroscopic distances can provide excellent sensitivity for gravitational measurements. I will describe progress on the design and construction of a two-meter-tall strontium atomic fountain that aims to leverage such atom interferometers to search for new interactions beyond the standard model via tests of the gravitational inverse square law and to make a new measurement of Newton’s gravitational constant. Moreover, I will discuss progress on MAGIS-100, a 100-meter-tall atom interferometer being built at Fermilab to serve as a prototype gravitational wave detector in the 0.3 – 3 Hz range and to search for ultralight dark matter.
This chapter introduces the fundamental principles and some of the applications of light-pulse atom interferometry. It includes tutorials on various atom optics techniques and on interferometer phase shift calculations. Recent advances in large momentum transfer atom optics and in the generation and manipulation of ultra-low-velocity-spread atom clouds have enabled atom interferometers that cover macroscopic scales in space (tens of centimeters) and in time (multiple seconds), dramatically improving interferometer sensitivity in a wide range of applications. This chapter reviews these advances and recent experiments performed with macroscopic scale atom interferometers in the 10-meter-tall atomic fountain at Stanford.
MAGIS-100 is a 100-meter atom interferometer currently being built at Fermilab and will be the worlds largest atom fountain. It will leverage modern atom optics techniques to search for dark matter, perform quantum atomic experiments, and detect gravitational waves at frequencies inaccessible to LIGO and LISA. Generation and precise control of meter-separated quantum atomic superpositions within the interferometer requires an agile laser system able to rapidly shift the optical frequency up to a rate of 100 GHz/s while maintaining a phase lock to our static frequency comb. To meet the power requirement of the experiment, the two interferometry lasers are coherently locked and must be robust to rapid frequency shifts. The interferometry laser's spatial mode is cleaned through fiber coupling and long free space propagation in vacuum with frequency noise introduced by the fiber suppressed by a PID lock. In addition to the scientific and technical hurdles in this experiment, there are complex laser safety issues. There are a total of twenty-four lasers and seven wavelengths ranging from 50mW to 100W, all within the same LCA.