Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

International Laser Safety Conference (ILSC)

Laser system for the 100-meter-tall MAGIS-100 atom interferometer

Kenneth DeRose

Published Mar 1, 2023• 0 citations
Publisher

Abstract

MAGIS-100 is a 100-meter atom interferometer currently being built at Fermilab and will be the worlds largest atom fountain. It will leverage modern atom optics techniques to search for dark matter, perform quantum atomic experiments, and detect gravitational waves at frequencies inaccessible to LIGO and LISA. Generation and precise control of meter-separated quantum atomic superpositions within the interferometer requires an agile laser system able to rapidly shift the optical frequency up to a rate of 100 GHz/s while maintaining a phase lock to our static frequency comb. To meet the power requirement of the experiment, the two interferometry lasers are coherently locked and must be robust to rapid frequency shifts. The interferometry laser's spatial mode is cleaned through fiber coupling and long free space propagation in vacuum with frequency noise introduced by the fiber suppressed by a PID lock. In addition to the scientific and technical hurdles in this experiment, there are complex laser safety issues. There are a total of twenty-four lasers and seven wavelengths ranging from 50mW to 100W, all within the same LCA.

DOI
10.2351/7.0001472

Related papers

Progress toward large-area strontium atom interferometry for precision gravitational measurements

Tim Kovachy

Atom interferometers in which atoms are delocalized over macroscopic distances can provide excellent sensitivity for gravitational measurements. I will describe progress on the design and construction of a two-meter-tall strontium atomic fountain that aims to leverage such atom interferometers to search for new interactions beyond the standard model via tests of the gravitational inverse square law and to make a new measurement of Newton’s gravitational constant. Moreover, I will discuss progress on MAGIS-100, a 100-meter-tall atom interferometer being built at Fermilab to serve as a prototype gravitational wave detector in the 0.3 – 3 Hz range and to search for ultralight dark matter.

Optical and Quantum Sensing and Precision Metrology•Mar 4, 2021•0 citations

Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100)

Mahiro Abe, P. Adamson, Marcel Borcean +45 more

Abstract MAGIS-100 is a next-generation quantum sensor under construction at Fermilab that aims to explore fundamental physics with atom interferometry over a 100 m baseline. This novel detector will search for ultralight dark matter, test quantum mechanics in new regimes, and serve as a technology pathfinder for future gravitational wave detectors in a previously unexplored frequency band. It combines techniques demonstrated in state-of-the-art 10-meter-scale atom interferometers with the latest technological advances of the world’s best atomic clocks. MAGIS-100 will provide a development platform for a future kilometer-scale detector that would be sufficiently sensitive to detect gravitational waves from known sources. Here we present the science case for the MAGIS concept, review the operating principles of the detector, describe the instrument design, and study the detector systematics.

arXiv:2104.02835•Quantum Science and Technology•Apr 12, 2021•294 citations

Large-scale atom interferometry for fundamental physics

O. L. Buchmueller, John R. Ellis, Ulrich Schneider

Atom interferometers measure quantum interference patterns in the wave functions of cold atoms that follow superpositions of different space-time trajectories. These can be sensitive to phase shifts induced by fundamental physics processes such as interactions with ultralight dark matter or the passage of gravitational waves. The capabilities of large-scale atom interferometers are illustrated by their estimated sensitivities to the possible interactions of ultralight dark matter with electrons and photons, and to gravitational waves in the frequency range around 1 Hz, intermediate between the peak sensitivities of the LIGO and LISA experiments. Atom interferometers can probe ultralight scalar couplings with much greater sensitivity than is currently available from probes of the Equivalence Principle. Their sensitivity to mid-frequency gravitational waves may open a window on mergers of masses intermediate between those discovered by the LIGO and Virgo experiments and the supermassive black holes present in the cores of galaxies, as well as fundamental physics processes in the early Universe such as first-order phase transitions and the evolution of networks of cosmic strings.

arXiv:2306.17726•Contemporary Physics•Apr 3, 2023•30 citations

A prototype differential atom interferometer for fundamental physics

Charles F. A. Baynham, Richard Hobson, O. L. Buchmueller +97 more

Abstract Gravitational waves and ultralight dark matter are among the most compelling frontiers in fundamental physics, motivating proposals for very-long-baseline atom interferometerssuch as AION 1 , MAGIS 2 , AICE 3 and AEDGE 4 that aim to detect at frequencies at which ground-based 5 and space-borne 6 laser interferometers lose sensitivity. Very-long-baseline atom interferometers look for signals by comparing the quantum phase evolution of widely separated atomic ensembles interrogated by a common laser. However, their performance depends critically on suppressing noise sources, particularly laser phase noise. The experimental validation of such noise rejection remains an important challenge. Here we demonstrate a prototype differential atom interferometer based on the single-photon clock transition of fermionic 87 Sr. Thus, we obtain a gradiometer configuration with a species intrinsically suited to kilometre-scale and space-baseline operation. The instrument operates at the standard quantum limit 7 with no excess noise beyond atom shot noise. The differential configuration maintains quantum-limited sensitivity in the presence of several radians of artificially injected laser phase noise per shot, which emulates the conditions expected in a very-long-baseline atom interferometer. We also demonstrate the recovery of coherent oscillatory signals across a broad frequency range under fully phase-randomized conditions, a capability that is inaccessible to a single interferometer operating in the same regime. These results provide an experimental validation of the noise-immune measurement principle underlying very-long-baseline atom interferometers and mark an important step towards next-generation quantum sensors for gravitational-wave detection and searches for ultralight dark matter 8,9 .

arXiv:2504.09158•Nature•Jun 17, 2026•14 citations

A compact laser system for a portable atom interferometry gravimeter

Qin Luo, Heng Zhang, Ke Zhang +4 more

A compact laser system for a portable 87Rb atom interferometry gravimeter has been demonstrated in this work. This laser system is based on frequency doubling of a single seed laser at the wavelength of 1560 nm. The frequency of the seed laser is controlled by a digital unit with an analog feedback circuit. By using this frequency control method, the frequency of the laser system can be shifted over 1 GHz. Based on this method, the Raman frequency can be locked on the F = 3 → F′ = 4 transition of 85Rb atoms. Moreover, the Raman sideband and the repumping laser are generated by a phase modulator, and it can generate different laser frequencies to meet the requirements of a typical atom interferometer. Additional sidebands in the Raman beam produced from the phase modulator are optimized and reduced, allowing us to observe atom interference with a free evolution time of 320 ms. The control unit including the laser system has been integrated into a box with a volume of 1.5 m × 0.6 m × 0.6 m, and the weight of which is only 150 kg. Using this compact optical scheme, our atomic gravimeter has achieved a sensitivity of 53 μGal/Hz1/2 and a resolution of better than 1 μGal (1 μGal = 1 × 10−8 m/s2) in an integration time of 3000 s.

Review of Scientific Instruments•Apr 1, 2019•44 citations

Coriolis Force Compensation and Laser Beam Delivery for 100-Meter Baseline Atom Interferometry

Jonah Glick, Zilin Chen, Tejas Deshpande +2 more

The Coriolis force is a significant source of systematic phase errors and dephasing in atom interferometry and is often compensated by counter-rotating the interferometry laser beam against Earth's rotation. We present a novel method for performing Coriolis force compensation for long-baseline atom interferometry which mitigates atom-beam misalignment due to beam rotation, an effect which is magnified by the long lever arm of the baseline length. The method involves adjustment of the angle of the interferometer beam prior to a magnifying telescope, enabling the beam to pivot around a tunable position along the interferometer baseline. By tuning the initial atom kinematics, and adjusting the angle with which the interferometer beam pivots about this point, we can ensure that the atoms align with the center of the beam during the atom optics laser pulses. This approach will be used in the MAGIS-100 atom interferometer and could also be applied to other long-baseline atom interferometers. An additional challenge associated with long baseline interferometry is that since long-baseline atom interferometers are often located outside of typical laboratory environments, facilities constraints may require lasers to be housed in a climate-controlled room a significant distance away from the main experiment. Nonlinear effects in optical fibers restrict the use of fiber-based transport of the high-power interferometry beam from the laser room to the experiment. We present the design of and prototype data from a laser transport system for MAGIS-100 that maintains robustness against alignment drifts despite the absence of a long fiber.

arXiv:2311.05714•Nov 9, 2023•1 citation
MAGIS-100 is a 100-meter atom interferometer currently being built at Fermilab and will be the worlds largest atom fountain. It will leverage modern atom optics techniques to search for dark matter, perform quantum atomic experiments, and detect gravitational waves at frequencies inaccessible to LIGO and LISA. Generation and precise control of meter-separated quantum atomic superpositions within the interferometer requires an agile laser system able to rapidly shift the optical frequency up to a rate of 100 GHz/s while maintaining a phase lock to our static frequency comb. To meet the power requirement of the experiment, the two interferometry lasers are coherently locked and must be robust to rapid frequency shifts. The interferometry laser's spatial mode is cleaned through fiber coupling and long free space propagation in vacuum with frequency noise introduced by the fiber suppressed by a PID lock. In addition to the scientific and technical hurdles in this experiment, there are complex laser safety issues. There are a total of twenty-four lasers and seven wavelengths ranging from 50mW to 100W, all within the same LCA.
Atom interferometers in which atoms are delocalized over macroscopic distances can provide excellent sensitivity for gravitational measurements. I will describe progress on the design and construction of a two-meter-tall strontium atomic fountain that aims to leverage such atom interferometers to search for new interactions beyond the standard model via tests of the gravitational inverse square law and to make a new measurement of Newton’s gravitational constant. Moreover, I will discuss progress on MAGIS-100, a 100-meter-tall atom interferometer being built at Fermilab to serve as a prototype gravitational wave detector in the 0.3 – 3 Hz range and to search for ultralight dark matter.
Abstract MAGIS-100 is a next-generation quantum sensor under construction at Fermilab that aims to explore fundamental physics with atom interferometry over a 100 m baseline. This novel detector will search for ultralight dark matter, test quantum mechanics in new regimes, and serve as a technology pathfinder for future gravitational wave detectors in a previously unexplored frequency band. It combines techniques demonstrated in state-of-the-art 10-meter-scale atom interferometers with the latest technological advances of the world’s best atomic clocks. MAGIS-100 will provide a development platform for a future kilometer-scale detector that would be sufficiently sensitive to detect gravitational waves from known sources. Here we present the science case for the MAGIS concept, review the operating principles of the detector, describe the instrument design, and study the detector systematics.
Atom interferometers measure quantum interference patterns in the wave functions of cold atoms that follow superpositions of different space-time trajectories. These can be sensitive to phase shifts induced by fundamental physics processes such as interactions with ultralight dark matter or the passage of gravitational waves. The capabilities of large-scale atom interferometers are illustrated by their estimated sensitivities to the possible interactions of ultralight dark matter with electrons and photons, and to gravitational waves in the frequency range around 1 Hz, intermediate between the peak sensitivities of the LIGO and LISA experiments. Atom interferometers can probe ultralight scalar couplings with much greater sensitivity than is currently available from probes of the Equivalence Principle. Their sensitivity to mid-frequency gravitational waves may open a window on mergers of masses intermediate between those discovered by the LIGO and Virgo experiments and the supermassive black holes present in the cores of galaxies, as well as fundamental physics processes in the early Universe such as first-order phase transitions and the evolution of networks of cosmic strings.
Abstract Gravitational waves and ultralight dark matter are among the most compelling frontiers in fundamental physics, motivating proposals for very-long-baseline atom interferometerssuch as AION 1 , MAGIS 2 , AICE 3 and AEDGE 4 that aim to detect at frequencies at which ground-based 5 and space-borne 6 laser interferometers lose sensitivity. Very-long-baseline atom interferometers look for signals by comparing the quantum phase evolution of widely separated atomic ensembles interrogated by a common laser. However, their performance depends critically on suppressing noise sources, particularly laser phase noise. The experimental validation of such noise rejection remains an important challenge. Here we demonstrate a prototype differential atom interferometer based on the single-photon clock transition of fermionic 87 Sr. Thus, we obtain a gradiometer configuration with a species intrinsically suited to kilometre-scale and space-baseline operation. The instrument operates at the standard quantum limit 7 with no excess noise beyond atom shot noise. The differential configuration maintains quantum-limited sensitivity in the presence of several radians of artificially injected laser phase noise per shot, which emulates the conditions expected in a very-long-baseline atom interferometer. We also demonstrate the recovery of coherent oscillatory signals across a broad frequency range under fully phase-randomized conditions, a capability that is inaccessible to a single interferometer operating in the same regime. These results provide an experimental validation of the noise-immune measurement principle underlying very-long-baseline atom interferometers and mark an important step towards next-generation quantum sensors for gravitational-wave detection and searches for ultralight dark matter 8,9 .
A compact laser system for a portable 87Rb atom interferometry gravimeter has been demonstrated in this work. This laser system is based on frequency doubling of a single seed laser at the wavelength of 1560 nm. The frequency of the seed laser is controlled by a digital unit with an analog feedback circuit. By using this frequency control method, the frequency of the laser system can be shifted over 1 GHz. Based on this method, the Raman frequency can be locked on the F = 3 → F′ = 4 transition of 85Rb atoms. Moreover, the Raman sideband and the repumping laser are generated by a phase modulator, and it can generate different laser frequencies to meet the requirements of a typical atom interferometer. Additional sidebands in the Raman beam produced from the phase modulator are optimized and reduced, allowing us to observe atom interference with a free evolution time of 320 ms. The control unit including the laser system has been integrated into a box with a volume of 1.5 m × 0.6 m × 0.6 m, and the weight of which is only 150 kg. Using this compact optical scheme, our atomic gravimeter has achieved a sensitivity of 53 μGal/Hz1/2 and a resolution of better than 1 μGal (1 μGal = 1 × 10−8 m/s2) in an integration time of 3000 s.
The Coriolis force is a significant source of systematic phase errors and dephasing in atom interferometry and is often compensated by counter-rotating the interferometry laser beam against Earth's rotation. We present a novel method for performing Coriolis force compensation for long-baseline atom interferometry which mitigates atom-beam misalignment due to beam rotation, an effect which is magnified by the long lever arm of the baseline length. The method involves adjustment of the angle of the interferometer beam prior to a magnifying telescope, enabling the beam to pivot around a tunable position along the interferometer baseline. By tuning the initial atom kinematics, and adjusting the angle with which the interferometer beam pivots about this point, we can ensure that the atoms align with the center of the beam during the atom optics laser pulses. This approach will be used in the MAGIS-100 atom interferometer and could also be applied to other long-baseline atom interferometers. An additional challenge associated with long baseline interferometry is that since long-baseline atom interferometers are often located outside of typical laboratory environments, facilities constraints may require lasers to be housed in a climate-controlled room a significant distance away from the main experiment. Nonlinear effects in optical fibers restrict the use of fiber-based transport of the high-power interferometry beam from the laser room to the experiment. We present the design of and prototype data from a laser transport system for MAGIS-100 that maintains robustness against alignment drifts despite the absence of a long fiber.