Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Quantitative Phase Imaging

Dual wavelength Hong-Ou-Mandel imaging

Ashley Lyons, Khales Kassem, Daniele Faccio, Jack Radford

Published Mar 12, 2024• 0 citations
Publisher

Abstract

Hong-Ou-Mandel (HOM) interferometry, manifesting as photon bunching at a beamsplitter, can provide high precision optical path length sensing yet is robust to phase noise and immune to phase-wrapping. In this work we demonstrate how the sensitivity of HOM based imaging can be enhanced using dual wavelength illumination whilst maintaining its high level of robustness. We observe a beating in the second order correlation function due to the interference between the two wavelengths bands with a periodicity determined by the wavelength separation. These small-scale features can be used to precisely determine optical path length at the nanometre scale whilst a coarse (micron scale) estimation can be obtained by measuring only one of the bands.

DOI
10.1117/12.3009777

Related papers

Sub-$\mu\mathrm{m}$ Axial Precision Depth Imaging with Entangled Two-Colour Hong-Ou-Mandel Microscopy

Cyril Torre, Alex McMillan, Jorge Monroy-Ruz +1 more

Hong-Ou-Mandel (HOM) interference results in a modified probability of bunching events when indistinguishable photons with a relative timing offset interact at a beamsplitter. Lyons et al. recently achieved attosecond precision in time delay measurement by applying a classical Fisher information analysis to HOM interference [1]. More recently an increase in the measurement precision has been shown by detuning the central wavelengths of the signal and idler from an entangled two-colour photon pair source and applied in temperature drift detection for optical fibres [2]. Here we exploit the timing resolution of the HOM interference to implement a robust 3D imaging microscope with tuneable sensitivity from millimetre to sub-micrometre.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 26, 2023•1 citation

High precision metrology from the fisher information of a Hong-Ou-Mandel interferometer

Ashley Lyons, George C. Knee, Eliot Bolduc +4 more

Quantum interference forces two indistinguishable input photons to depart a beamsplitter in the same (of two possible) spatial output modes; this is known as the Hong-Ou-Mandel (HOM) effect. It provides a quantitative way of measuring the distinguishability between two photons and also has been utilised to determine their relative temporal delays [1, 2]. HOM interferometry offers numerous advantages over its classical counterpart, most importantly it lacks any dependence on the phase of the photons and therefore can potentially provide reliable measurements in environments where the phase is unstable. To date there have been very few investigations on the precision that is achievable with HOM interferometry. Experiments with collinear geometries have yielded sensitivities as low as 0.1fs however these approaches are limited to measurements of birefringence and other polarisation dependent effects [3, 4], as the precision derives from the inherently stable shared path of the photon pairs. Typical non-shared path HOM interferometers exhibit resolution of roughly 1–3 fs (0.3–1 μm).

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2017•0 citations

Attosecond delay metrology beyond the photon coherence time with spectrally resolved Hong-Ou-Mandel interferometry

Yingwen Zhang, Kyle Jordan, Duncan England +3 more

Hong-Ou-Mandel (HOM) interferometry enables delay estimation at the quantum precision limit but is traditionally constrained to path differences within the coherence time of the interfering photons. Here, we demonstrate single-measurement path-delay sensing at the measurement Cramer-Rao bound using spectrally resolved HOM interference, thereby removing the conventional dynamic-range limitation imposed by the photon coherence window, with no scanning required for calibration. By extracting delay information from the spectral interference fringes of spectrally entangled photon pairs, we retain near-optimal sensitivity over an operational range exceeding the photon coherence time by over two orders of magnitude. Using one million detected photon pairs, we achieve a time-delay precision of 20 attosecond (6 nm), while real-time operation (at 1 Hz) yields 330 attosecond (100 nm) precision. Because the estimator relies on fringe periodicity rather than absolute coincidence rates, the method is intrinsically robust to photon losses and variations in interference visibility, eliminating the need for recalibration. As a practical demonstration, we measure the thickness of a 300 um transmissive target with nanometer-scale precision. These results mark a significant step towards deploying quantum-limited measurements in real-world sensing applications using HOM interferometry.

quant-pharXiv:2607.16849•Reports on Progress in Physics•Jul 21, 2026•0 citations

Attosecond-resolution Hong-Ou-Mandel interferometry

Ashley Lyons, George C. Knee, Eliot Bolduc +4 more

When two indistinguishable photons are each incident on separate input ports of a beamsplitter, they "bunch" deterministically, exiting via the same port as a direct consequence of their bosonic nature. This two-photon interference effect has long-held the potential for application in precision measurement of time delays, such as those induced by transparent specimens with unknown thickness profiles. However, the technique has never achieved resolutions significantly better than the few-femtosecond (micrometer) scale other than in a common-path geometry that severely limits applications. We develop the precision of Hong-Ou-Mandel interferometry toward the ultimate limits dictated by statistical estimation theory, achieving few-attosecond (or nanometer path length) scale resolutions in a dual-arm geometry, thus providing access to length scales pertinent to cell biology and monoatomic layer two-dimensional materials.

arXiv:1708.08351•Science Advances•May 4, 2018•213 citations

Near‐Video Frame Rate Quantum Sensing Using Hong–Ou–Mandel Interferometry

Sandeep Singh, Vimlesh Kumar, Varun Sharma +2 more

Abstract Hong–Ou–Mandel (HOM) interference, bunching of two indistinguishable photons on a balanced beam‐splitter, has emerged as a promising tool for quantum sensing. There is a need for wide spectral‐bandwidth photon pairs (for high‐resolution sensing) with high brightness (for fast sensing). Here, the generation of photon‐pairs with flexible spectral‐bandwidth even using single‐frequency, continuous‐wave diode laser enabling high‐precision, real‐time sensing is showed. Using 1‐mm‐long periodically‐poled KTP crystal, degenerate, photon‐pairs with spectral‐bandwidth of 163.42±1.68 nm are produced resulting in a HOM‐dip width of 4.01±0.04 m to measure a displacement of 60 nm, and sufficiently high brightness to enable the measurement of vibrations with amplitude of 205 ± 0.75 nm and frequency of 8 Hz. Fisher‐information (FI) and maximum likelihood estimation enables optical delay measurements as small as 4.97 nm with precision (Cramér–Rao bound) and accuracy of 0.89 and 0.54 nm, respectively, therefore showing HOM sensing capability for real‐time, precision‐augmented, in‐field quantum sensing applications.

arXiv:2304.13300•Advanced Quantum Technologies•Sep 21, 2023•7 citations

Variation of the Hong-Ou-Mandel interference dip with crystal length

Sandeep Singh, Varun Sharma, Vimlesh Kumar +1 more

Two-photon interference, commonly known as Hong-Ou-Mandel (HOM) interference [1] , has attracted a great deal of interest in quantum sensing, including the precision timing measurements [2] and quantum optical coherence tomography [3] . While the dip of the HOM interference is the direct measure of the purity of the single-photon, the width of the HOM dip relates to the coherence time of the interfering photons. The broad consensus for using the HOM interferometer for sensing application remained the HOM dip width as the limiting factor for the precision measurements. As a consequence, the ultra-broadband photon sources have long been hailed as a vital prerequisite for ultra-precise HOM interferometry. Here, we have studied the variation in the width of the HOM dip with the crystal length for the continuous-wave pump laser and measured the HOM dip as low as 8.2 ± 0.2 µm corresponding to the spectral width of the single-photon source of 79.6±1.9 nm useful for sensitive sensing applications.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 21, 2021•1 citation
Hong-Ou-Mandel (HOM) interferometry, manifesting as photon bunching at a beamsplitter, can provide high precision optical path length sensing yet is robust to phase noise and immune to phase-wrapping. In this work we demonstrate how the sensitivity of HOM based imaging can be enhanced using dual wavelength illumination whilst maintaining its high level of robustness. We observe a beating in the second order correlation function due to the interference between the two wavelengths bands with a periodicity determined by the wavelength separation. These small-scale features can be used to precisely determine optical path length at the nanometre scale whilst a coarse (micron scale) estimation can be obtained by measuring only one of the bands.
Sub-μm\mu\mathrm{m}μm Axial Precision Depth Imaging with Entangled Two-Colour Hong-Ou-Mandel Microscopy
Hong-Ou-Mandel (HOM) interference results in a modified probability of bunching events when indistinguishable photons with a relative timing offset interact at a beamsplitter. Lyons et al. recently achieved attosecond precision in time delay measurement by applying a classical Fisher information analysis to HOM interference [1]. More recently an increase in the measurement precision has been shown by detuning the central wavelengths of the signal and idler from an entangled two-colour photon pair source and applied in temperature drift detection for optical fibres [2]. Here we exploit the timing resolution of the HOM interference to implement a robust 3D imaging microscope with tuneable sensitivity from millimetre to sub-micrometre.
Quantum interference forces two indistinguishable input photons to depart a beamsplitter in the same (of two possible) spatial output modes; this is known as the Hong-Ou-Mandel (HOM) effect. It provides a quantitative way of measuring the distinguishability between two photons and also has been utilised to determine their relative temporal delays [1, 2]. HOM interferometry offers numerous advantages over its classical counterpart, most importantly it lacks any dependence on the phase of the photons and therefore can potentially provide reliable measurements in environments where the phase is unstable. To date there have been very few investigations on the precision that is achievable with HOM interferometry. Experiments with collinear geometries have yielded sensitivities as low as 0.1fs however these approaches are limited to measurements of birefringence and other polarisation dependent effects [3, 4], as the precision derives from the inherently stable shared path of the photon pairs. Typical non-shared path HOM interferometers exhibit resolution of roughly 1–3 fs (0.3–1 μm).
Hong-Ou-Mandel (HOM) interferometry enables delay estimation at the quantum precision limit but is traditionally constrained to path differences within the coherence time of the interfering photons. Here, we demonstrate single-measurement path-delay sensing at the measurement Cramer-Rao bound using spectrally resolved HOM interference, thereby removing the conventional dynamic-range limitation imposed by the photon coherence window, with no scanning required for calibration. By extracting delay information from the spectral interference fringes of spectrally entangled photon pairs, we retain near-optimal sensitivity over an operational range exceeding the photon coherence time by over two orders of magnitude. Using one million detected photon pairs, we achieve a time-delay precision of 20 attosecond (6 nm), while real-time operation (at 1 Hz) yields 330 attosecond (100 nm) precision. Because the estimator relies on fringe periodicity rather than absolute coincidence rates, the method is intrinsically robust to photon losses and variations in interference visibility, eliminating the need for recalibration. As a practical demonstration, we measure the thickness of a 300 um transmissive target with nanometer-scale precision. These results mark a significant step towards deploying quantum-limited measurements in real-world sensing applications using HOM interferometry.
When two indistinguishable photons are each incident on separate input ports of a beamsplitter, they "bunch" deterministically, exiting via the same port as a direct consequence of their bosonic nature. This two-photon interference effect has long-held the potential for application in precision measurement of time delays, such as those induced by transparent specimens with unknown thickness profiles. However, the technique has never achieved resolutions significantly better than the few-femtosecond (micrometer) scale other than in a common-path geometry that severely limits applications. We develop the precision of Hong-Ou-Mandel interferometry toward the ultimate limits dictated by statistical estimation theory, achieving few-attosecond (or nanometer path length) scale resolutions in a dual-arm geometry, thus providing access to length scales pertinent to cell biology and monoatomic layer two-dimensional materials.
Abstract Hong–Ou–Mandel (HOM) interference, bunching of two indistinguishable photons on a balanced beam‐splitter, has emerged as a promising tool for quantum sensing. There is a need for wide spectral‐bandwidth photon pairs (for high‐resolution sensing) with high brightness (for fast sensing). Here, the generation of photon‐pairs with flexible spectral‐bandwidth even using single‐frequency, continuous‐wave diode laser enabling high‐precision, real‐time sensing is showed. Using 1‐mm‐long periodically‐poled KTP crystal, degenerate, photon‐pairs with spectral‐bandwidth of 163.42±1.68 nm are produced resulting in a HOM‐dip width of 4.01±0.04 m to measure a displacement of 60 nm, and sufficiently high brightness to enable the measurement of vibrations with amplitude of 205 ± 0.75 nm and frequency of 8 Hz. Fisher‐information (FI) and maximum likelihood estimation enables optical delay measurements as small as 4.97 nm with precision (Cramér–Rao bound) and accuracy of 0.89 and 0.54 nm, respectively, therefore showing HOM sensing capability for real‐time, precision‐augmented, in‐field quantum sensing applications.
Two-photon interference, commonly known as Hong-Ou-Mandel (HOM) interference [1] , has attracted a great deal of interest in quantum sensing, including the precision timing measurements [2] and quantum optical coherence tomography [3] . While the dip of the HOM interference is the direct measure of the purity of the single-photon, the width of the HOM dip relates to the coherence time of the interfering photons. The broad consensus for using the HOM interferometer for sensing application remained the HOM dip width as the limiting factor for the precision measurements. As a consequence, the ultra-broadband photon sources have long been hailed as a vital prerequisite for ultra-precise HOM interferometry. Here, we have studied the variation in the width of the HOM dip with the crystal length for the continuous-wave pump laser and measured the HOM dip as low as 8.2 ± 0.2 µm corresponding to the spectral width of the single-photon source of 79.6±1.9 nm useful for sensitive sensing applications.