Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Springer theses

Terahertz Vibrational Molecular Clock

Kon H. Leung

Published Dec 28, 2023• 0 citations
Publisher
DOI
10.1007/978-3-031-47647-1_5

Related papers

Molecular lattice clock with long vibrational coherence

S. S. Kondov, C.-H. Lee, K. H. Leung +4 more

arXiv:1904.04891•Nature Physics•Aug 19, 2019•86 citations

Molecular lattice clock with long vibrational coherence (Conference Presentation)

Hendrick Bekker

Optical and Quantum Sensing and Precision Metrology II•Mar 9, 2020•0 citations

Towards a Molecular Lattice Clock: Magic-Wavelength Vibrational Spectroscopy of Sr$_{\mathrm{2}}$

Kon H. Leung, Chih-Hsi Lee, Stanimir Kondov +2 more

Bulletin of the American Physical Society•May 29, 2018•0 citations

New Accuracy Record for Molecular Lattice Clock

Charles Day

Researchers have attained a 100-fold increase in the accuracy of a molecular clock that could serve as a terahertz-frequency standard and as a platform for investigating new physics.By Charles Day M olecules can rotate, vibrate, and twist.With each of those degrees of freedom comes a ladder of quantized energy levels whose spacings typically occupy the terahertz band.Because the ladder's steps are tiny, molecules are exquisitely sensitive probes of internal and external fields.But the sensitivity complicates the two principal operations needed to build a working probe: cooling and trapping.In 2019 Tanya Zelevinsky of Columbia University and her collaborators overcame those hurdles to measure a vibrational transition in diatomic strontium to one part in 10 12 .Now, after four years of improvements to the experiment, the team has attained an accuracy 100 times greater [1].Zelevinsky and her team chose Sr 2 for their molecular clock Running a molecular lattice clock requires multiple lasers, mirrors, prisms, and other optical components.

Physics•Mar 28, 2023•1 citation

Molecular Optical Lattice Clock

Tanya Zelevinsky, Svetlana Kotochigova, Jun Ye

APS•May 1, 2008•0 citations

Terahertz Vibrational Molecular Clock with Systematic Uncertainty at the 10−14 Level

Kon H. Leung, Brandon Iritani, Emily Tiberi +4 more

Neutral quantum absorbers in optical lattices have emerged as a leading platform for achieving clocks with exquisite spectroscopic resolution.However, the studies of these clocks and their systematic shifts have so far been limited to atoms.Here, we extend this architecture to an ensemble of diatomic molecules and experimentally realize an accurate lattice clock based on pure molecular vibration.We evaluate the leading systematics, including the characterization of nonlinear trap-induced light shifts, achieving a total systematic uncertainty of 4.6 × 10 -14 .The absolute frequency of the vibrational splitting is measured to be 31 825 183 207 592.8(5.1)Hz, enabling the dissociation energy of our molecule to be determined with record accuracy.Our results represent an important milestone in molecular spectroscopy and THzfrequency standards, and may be generalized to other neutral molecular species with applications for fundamental physics, including tests of molecular quantum electrodynamics and the search for new interactions.

arXiv:2209.10864•Physical Review X•Mar 28, 2023•42 citations
Towards a Molecular Lattice Clock: Magic-Wavelength Vibrational Spectroscopy of Sr2_{\mathrm{2}}2​
Researchers have attained a 100-fold increase in the accuracy of a molecular clock that could serve as a terahertz-frequency standard and as a platform for investigating new physics.By Charles Day M olecules can rotate, vibrate, and twist.With each of those degrees of freedom comes a ladder of quantized energy levels whose spacings typically occupy the terahertz band.Because the ladder's steps are tiny, molecules are exquisitely sensitive probes of internal and external fields.But the sensitivity complicates the two principal operations needed to build a working probe: cooling and trapping.In 2019 Tanya Zelevinsky of Columbia University and her collaborators overcame those hurdles to measure a vibrational transition in diatomic strontium to one part in 10 12 .Now, after four years of improvements to the experiment, the team has attained an accuracy 100 times greater [1].Zelevinsky and her team chose Sr 2 for their molecular clock Running a molecular lattice clock requires multiple lasers, mirrors, prisms, and other optical components.
Neutral quantum absorbers in optical lattices have emerged as a leading platform for achieving clocks with exquisite spectroscopic resolution.However, the studies of these clocks and their systematic shifts have so far been limited to atoms.Here, we extend this architecture to an ensemble of diatomic molecules and experimentally realize an accurate lattice clock based on pure molecular vibration.We evaluate the leading systematics, including the characterization of nonlinear trap-induced light shifts, achieving a total systematic uncertainty of 4.6 × 10 -14 .The absolute frequency of the vibrational splitting is measured to be 31 825 183 207 592.8(5.1)Hz, enabling the dissociation energy of our molecule to be determined with record accuracy.Our results represent an important milestone in molecular spectroscopy and THzfrequency standards, and may be generalized to other neutral molecular species with applications for fundamental physics, including tests of molecular quantum electrodynamics and the search for new interactions.