Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Europhysics Letters (EPL)

Variance properties of the microwave absorption spectrum of an ensemble of nitrogen vacancy centers in diamond

R. Chelly, T. Chang, Itamar Holzman, T. Cohen, Joseph Kantorovitsch, Michael Stern

Published Nov 30, 2023• 2 citations
Publisher

Abstract

Abstract This work presents an original method based on the variance properties of the microwave absorption spectrum of an ensemble of nitrogen vacancy centers in diamond. The spectrum is measured optically. A compact and simple device is designed to optimize the photon collection. We conduct a quantitative comparison of the ensemble's optical signal in both the visible and near infrared range. Using the enhanced signal-to-noise ratio achieved through the device geometry we perform real-time DC magnetometry at moderate light and microwave powers. Under these conditions, the amplitude of a DC magnetic field can be extracted from the variance of the microwave absorption spectrum in a fast and reproducible manner, without the burden of complex fitting techniques.

DOI
10.1209/0295-5075/ad116d

Related papers

Wide bandwidth instantaneous radio frequency spectrum analyzer based on nitrogen vacancy centers in diamond

Mayeul Chipaux, Loïc Toraille, C. Larat +4 more

We propose an original analog method to perform instantaneous and quantitative spectral analysis of microwave signals. An ensemble of nitrogen-vacancy (NV) centers held in a diamond plate is pumped by a 532 nm laser. Its photoluminescence is imaged through an optical microscope and monitored by a digital camera. An incoming microwave signal is converted into a microwave field in the area of the NV centers by a loop shaped antenna. The resonances induced by the magnetic component of that field are detected through a decrease of the NV centers photoluminescence. A magnetic field gradient induces a Zeeman shift of the resonances and transforms the frequency information into spatial information, which allows for the simultaneous analysis of the microwave signal in the entire frequency bandwidth of the device. The time dependent spectral analysis of an amplitude modulated microwave signal is demonstrated over a bandwidth of 600 MHz, associated to a frequency resolution of 7 MHz , and a refresh rate of 4 ms. With such integration time, a field of a few hundreds of μW can be detected. Since the optical properties of NV centers can be maintained even in high magnetic field, we estimate that an optimized device could allow frequency analysis in a range of 30 GHz, only limited by the amplitude of the magnetic field gradient. In addition, an increase of the NV centers quantity could lead both to an increase of the microwave sensitivity and to a decrease of the minimum refresh rate down to a few μs.

arXiv:1509.01395•Applied Physics Letters•Dec 7, 2015•60 citations

High-contrast absorption magnetometry in the visible to near-infrared range with nitrogen-vacancy ensembles

Florian Schall, Felix A. Hahl, Lukas Lindner +6 more

Magnetometry with nitrogen-vacancy (NV) centers in diamond has so far been measured via emission of light from NV centers or via absorption at the singlet transition at 1042 nm. Here, we demonstrate a phenomenon of broadband optical absorption by the NV centers starting in the emission wavelength and reaching up to 1000 nm. The measurements are enabled by a high-finesse cavity, which is used for room-temperature continuous wave pump-probe experiments. The red to infrared probe beam shows the typical optically detected magnetic resonance (ODMR) signal of the NV spin with contrasts up to 42 %. This broadband optical absorption has not yet been reported in terms of NV magnetometry. We argue that the lower level of the absorbing transition could be the energetically lower NV singlet state, based on the increased optical absorption for a resonant microwave field and the spectral behavior. Investigations of the photon-shot-noise-limited sensitivity show improvements with increasing probe wavelength, reaching an optimum of 7.5pT/Hz. The results show significantly improved ODMR contrast compared to emission-based magnetometry. This opens a new detection wavelength regime with coherent laser signal detection for high-sensitivity NV magnetometry.

arXiv:2412.07798•Optics Express•Jan 23, 2025•4 citations

Nitrogen-vacancy ensemble magnetometry based on pump absorption

Sepehr Ahmadi, Haitham A. R. El-Ella, Adam M. Wojciechowski +4 more

We demonstrate magnetic-field sensing using an ensemble of nitrogen-vacancy centers by recording the variation in the pump-light absorption due to the spin-polarization dependence of the total ground-state population. Using a 532 nm pump laser, we measure the absorption of native nitrogen-vacancy centers in a chemical-vapor-deposited diamond placed in a resonant optical cavity. For a laser pump power of 0.4 W and a cavity finesse of 45, we obtain a noise floor of $\ensuremath{\sim}100 \mathrm{nT}/\sqrt{\mathrm{Hz}}$ spanning a bandwidth up to 125 Hz. We project a photon shot-noise-limited sensitivity of $\ensuremath{\sim}1 \mathrm{pT}/\sqrt{\mathrm{Hz}}$ by optimizing the nitrogen-vacancy concentration and the detection method.

arXiv:1712.05161•Physical review. B./Physical review. B•Jan 11, 2018•23 citations

High-frequency resolution diamond nitrogen-vacancy center wide-spectrum imaging technology

Yuanyuan Shen, Bo Wang, Dongqian Ke +10 more

High-resolution wide-spectrum measurement techniques have important applications in fields such as astronomy, wireless communication, and medical imaging. Nitrogen-vacancy (NV) center in diamond is well known for its high stability, high sensitivity, real-time monitoring, single-point detection, and suitability for long-term measurement, and has an outstanding choice for spectrum analyzers. Currently, spectrum analyzers based on NV centers as detectors can perform real-time spectrum analysis in the range of several tens of gigahertz, but their frequency resolution is limited to a MHz level. In this study, we construct a quantum diamond microwave spectrum imaging system by combining continuous wave-mixing techniques. According to the spin-related properties of the NV center in diamond, we implement optical pumping by 532 nm green laser light illuminating the diamond NV center. A spherical magnet is used to produce a magnetic field gradient along the direction of the diamond crystal. By adjusting the size and direction of the magnetic field gradient, spatial encoding of the resonance frequency of the NV center is achieved. The magnetic field gradient induces the Zeeman effect on the diamond surface at different positions, generating corresponding ODMR signals. Through accurate programming, we coordinate the frequency scanning step size of the microwave source with the camera exposure and image storage time, and synchronize them circularly according to the order of image acquisition. Ultimately, after algorithmic processing, we successfully obtain comprehensive spectrum data in a range from 900 MHz to 6.0 GHz. Within the measurable spectrum range, the system employs continuous wave-mixing, simultaneously applying resonant microwaves and slightly detuning auxiliary microwaves to effectively excite the NV center. This method triggers off microwave interference effects, disrupting the balance between laser-induced polarization and microwave-induced spontaneous relaxation. Specifically, microwave interference causes the phase and amplitude of the fluorescence signal to change, leading to the generation of alternating current fluorescence signals. This further enhances the response of the NV magnetometer to weak microwave signals. The method enables the system to achieve a frequency resolution of 1 Hz in the measurable spectrum range, and it can separately measure the frequency resolution of multiple frequency points with a frequency step size of 1 MHz. The research results indicate that the wide-spectrum measurement based on NV centers can achieve sub-hertz frequency resolution, providing robust technical support for future spectrum analysis and applications.

Acta Physica Sinica•Jan 1, 2024•1 citation

Absorptive laser threshold magnetometry: combining visible diamond Raman lasers and nitrogen-vacancy centres

Sarath Raman Nair, Lachlan J. Rogers, David James Spence +5 more

Abstract We propose a high-sensitivity magnetometry scheme based on a diamond Raman laser with visible pump absorption by an ensemble of coherently microwave driven negatively charged nitrogen-vacancy centres (NV−) in the same diamond crystal. The NV− centres’ absorption and emission are spin-dependent. We show how the varying absorption of the NV− centres changes the Raman laser output. A shift in the diamond Raman laser threshold and output occurs with the external magnetic field and microwave driving. We develop a theoretical framework with steady-state solutions to describe the effects of coherently driven NV− centres including the charge state switching between NV− and its neutral charge state NV0 in a diamond Raman laser. We discuss that such a laser working at the threshold can be employed for magnetic field sensing. In contrast to previous studies on NV− magnetometry with visible laser absorption, the laser threshold magnetometry method is expected to have low technical noise, due to low background light in the measurement signal. For magnetic-field sensing, we project a shot-noise limited DC sensitivity of a few pT / H z in a well-calibrated cavity with realistic parameters. This sensor employs the broad visible absorption of NV− centres and unlike previous laser threshold magnetometry proposals it does not rely on active NV− centre lasing or an infrared laser medium at the specific wavelength of the NV− centre’s infrared absorption line.

arXiv:2101.08084•Materials for Quantum Technology•Apr 29, 2021•12 citations

Vector magnetometry using cavity-enhanced microwave readout in nitrogen-vacancy diamond

Reginald Wilcox, David Phillips, Matthew Steinecker +6 more

We demonstrate $4π$-steradian vector magnetic field sensing using an ensemble of nitrogen-vacancy (NV) centers in a single-crystal diamond coupled to a microwave (MW) cavity. The MW cavity enhances the spin-photon coupling which enables efficient, high-contrast spin-state readout via MW interrogation and removes the need for bulky optical collection components. An applied AC bias magnetic field lifts the zero-field degeneracy of the four crystallographic NV orientations, allowing each orientation to be individually addressed and used for vector reconstruction of the magnetic field. The resulting magnetometer has a 40\% contrast (20x higher than typical for optical spin-ensemble readout) and achieves a single-axis sensitivity of 250 pT/$\sqrt{\mathrm{Hz}}$ which is flat from DC to 1 kHz. Noise models of the composite spin-cavity system establish MW amplitude noise as the dominant noise source and predict a thermal noise limit of 2 pT/$\sqrt{\mathrm{Hz}}$.

quant-pharXiv:2511.11561•Physical Review Applied•Nov 17, 2025•2 citations
Abstract This work presents an original method based on the variance properties of the microwave absorption spectrum of an ensemble of nitrogen vacancy centers in diamond. The spectrum is measured optically. A compact and simple device is designed to optimize the photon collection. We conduct a quantitative comparison of the ensemble's optical signal in both the visible and near infrared range. Using the enhanced signal-to-noise ratio achieved through the device geometry we perform real-time DC magnetometry at moderate light and microwave powers. Under these conditions, the amplitude of a DC magnetic field can be extracted from the variance of the microwave absorption spectrum in a fast and reproducible manner, without the burden of complex fitting techniques.
We propose an original analog method to perform instantaneous and quantitative spectral analysis of microwave signals. An ensemble of nitrogen-vacancy (NV) centers held in a diamond plate is pumped by a 532 nm laser. Its photoluminescence is imaged through an optical microscope and monitored by a digital camera. An incoming microwave signal is converted into a microwave field in the area of the NV centers by a loop shaped antenna. The resonances induced by the magnetic component of that field are detected through a decrease of the NV centers photoluminescence. A magnetic field gradient induces a Zeeman shift of the resonances and transforms the frequency information into spatial information, which allows for the simultaneous analysis of the microwave signal in the entire frequency bandwidth of the device. The time dependent spectral analysis of an amplitude modulated microwave signal is demonstrated over a bandwidth of 600 MHz, associated to a frequency resolution of 7 MHz , and a refresh rate of 4 ms. With such integration time, a field of a few hundreds of μW can be detected. Since the optical properties of NV centers can be maintained even in high magnetic field, we estimate that an optimized device could allow frequency analysis in a range of 30 GHz, only limited by the amplitude of the magnetic field gradient. In addition, an increase of the NV centers quantity could lead both to an increase of the microwave sensitivity and to a decrease of the minimum refresh rate down to a few μs.
Magnetometry with nitrogen-vacancy (NV) centers in diamond has so far been measured via emission of light from NV centers or via absorption at the singlet transition at 1042 nm. Here, we demonstrate a phenomenon of broadband optical absorption by the NV centers starting in the emission wavelength and reaching up to 1000 nm. The measurements are enabled by a high-finesse cavity, which is used for room-temperature continuous wave pump-probe experiments. The red to infrared probe beam shows the typical optically detected magnetic resonance (ODMR) signal of the NV spin with contrasts up to 42 %. This broadband optical absorption has not yet been reported in terms of NV magnetometry. We argue that the lower level of the absorbing transition could be the energetically lower NV singlet state, based on the increased optical absorption for a resonant microwave field and the spectral behavior. Investigations of the photon-shot-noise-limited sensitivity show improvements with increasing probe wavelength, reaching an optimum of 7.5pT/Hz. The results show significantly improved ODMR contrast compared to emission-based magnetometry. This opens a new detection wavelength regime with coherent laser signal detection for high-sensitivity NV magnetometry.
We demonstrate magnetic-field sensing using an ensemble of nitrogen-vacancy centers by recording the variation in the pump-light absorption due to the spin-polarization dependence of the total ground-state population. Using a 532 nm pump laser, we measure the absorption of native nitrogen-vacancy centers in a chemical-vapor-deposited diamond placed in a resonant optical cavity. For a laser pump power of 0.4 W and a cavity finesse of 45, we obtain a noise floor of $\ensuremath{\sim}100 \mathrm{nT}/\sqrt{\mathrm{Hz}}$ spanning a bandwidth up to 125 Hz. We project a photon shot-noise-limited sensitivity of $\ensuremath{\sim}1 \mathrm{pT}/\sqrt{\mathrm{Hz}}$ by optimizing the nitrogen-vacancy concentration and the detection method.
High-resolution wide-spectrum measurement techniques have important applications in fields such as astronomy, wireless communication, and medical imaging. Nitrogen-vacancy (NV) center in diamond is well known for its high stability, high sensitivity, real-time monitoring, single-point detection, and suitability for long-term measurement, and has an outstanding choice for spectrum analyzers. Currently, spectrum analyzers based on NV centers as detectors can perform real-time spectrum analysis in the range of several tens of gigahertz, but their frequency resolution is limited to a MHz level. In this study, we construct a quantum diamond microwave spectrum imaging system by combining continuous wave-mixing techniques. According to the spin-related properties of the NV center in diamond, we implement optical pumping by 532 nm green laser light illuminating the diamond NV center. A spherical magnet is used to produce a magnetic field gradient along the direction of the diamond crystal. By adjusting the size and direction of the magnetic field gradient, spatial encoding of the resonance frequency of the NV center is achieved. The magnetic field gradient induces the Zeeman effect on the diamond surface at different positions, generating corresponding ODMR signals. Through accurate programming, we coordinate the frequency scanning step size of the microwave source with the camera exposure and image storage time, and synchronize them circularly according to the order of image acquisition. Ultimately, after algorithmic processing, we successfully obtain comprehensive spectrum data in a range from 900 MHz to 6.0 GHz. Within the measurable spectrum range, the system employs continuous wave-mixing, simultaneously applying resonant microwaves and slightly detuning auxiliary microwaves to effectively excite the NV center. This method triggers off microwave interference effects, disrupting the balance between laser-induced polarization and microwave-induced spontaneous relaxation. Specifically, microwave interference causes the phase and amplitude of the fluorescence signal to change, leading to the generation of alternating current fluorescence signals. This further enhances the response of the NV magnetometer to weak microwave signals. The method enables the system to achieve a frequency resolution of 1 Hz in the measurable spectrum range, and it can separately measure the frequency resolution of multiple frequency points with a frequency step size of 1 MHz. The research results indicate that the wide-spectrum measurement based on NV centers can achieve sub-hertz frequency resolution, providing robust technical support for future spectrum analysis and applications.
Abstract We propose a high-sensitivity magnetometry scheme based on a diamond Raman laser with visible pump absorption by an ensemble of coherently microwave driven negatively charged nitrogen-vacancy centres (NV−) in the same diamond crystal. The NV− centres’ absorption and emission are spin-dependent. We show how the varying absorption of the NV− centres changes the Raman laser output. A shift in the diamond Raman laser threshold and output occurs with the external magnetic field and microwave driving. We develop a theoretical framework with steady-state solutions to describe the effects of coherently driven NV− centres including the charge state switching between NV− and its neutral charge state NV0 in a diamond Raman laser. We discuss that such a laser working at the threshold can be employed for magnetic field sensing. In contrast to previous studies on NV− magnetometry with visible laser absorption, the laser threshold magnetometry method is expected to have low technical noise, due to low background light in the measurement signal. For magnetic-field sensing, we project a shot-noise limited DC sensitivity of a few pT / H z in a well-calibrated cavity with realistic parameters. This sensor employs the broad visible absorption of NV− centres and unlike previous laser threshold magnetometry proposals it does not rely on active NV− centre lasing or an infrared laser medium at the specific wavelength of the NV− centre’s infrared absorption line.
We demonstrate 4π4π4π-steradian vector magnetic field sensing using an ensemble of nitrogen-vacancy (NV) centers in a single-crystal diamond coupled to a microwave (MW) cavity. The MW cavity enhances the spin-photon coupling which enables efficient, high-contrast spin-state readout via MW interrogation and removes the need for bulky optical collection components. An applied AC bias magnetic field lifts the zero-field degeneracy of the four crystallographic NV orientations, allowing each orientation to be individually addressed and used for vector reconstruction of the magnetic field. The resulting magnetometer has a 40\% contrast (20x higher than typical for optical spin-ensemble readout) and achieves a single-axis sensitivity of 250 pT/Hz\sqrt{\mathrm{Hz}}Hz​ which is flat from DC to 1 kHz. Noise models of the composite spin-cavity system establish MW amplitude noise as the dominant noise source and predict a thermal noise limit of 2 pT/Hz\sqrt{\mathrm{Hz}}Hz​.