Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Integrated Photonics and Vacuum Package Development for a Cold-Atom Interferometer.

Peter D. D. Schwindt

Published Apr 1, 2022• 0 citations
Publisher
DOI
10.2172/2002485

Related papers

Development of a multi-species cold atom interferometer

Clément Diboune, Nassim Zahzam, Yannick Bidel +2 more

Bulletin of the American Physical Society•May 29, 2018•0 citations

COLD ATOM INTERFEROMETERS BASED ON DIFFRACTIVE OPTICS AND INTEGRATED PHOTONICS.

Jongmin Lee

•Feb 1, 2021•0 citations

COLD ATOM INTERFEROMETERS BASED ON DIFFRACTIVE OPTICS AND INTEGRATED PHOTONICS.

Jongmin Lee

Motivation for a compact atom interferometer (AI) Sandia Development in SIGMA Grand Challenge (GC) Passively pumped vacuum package Integrated photonics platform AI demonstration with compact sensor head and diffractive optics Conclude ≈1 mm

•Feb 1, 2021•0 citations

A compact cold-atom interferometer with a high data-rate grating magneto-optical trap and a photonic-integrated-circuit-compatible laser system

Jongmin Lee, Roger Ding, Justin Christensen +16 more

Abstract The extreme miniaturization of a cold-atom interferometer accelerometer requires the development of novel technologies and architectures for the interferometer subsystems. Here, we describe several component technologies and a laser system architecture to enable a path to such miniaturization. We developed a custom, compact titanium vacuum package containing a microfabricated grating chip for a tetrahedral grating magneto-optical trap (GMOT) using a single cooling beam. In addition, we designed a multi-channel photonic-integrated-circuit-compatible laser system implemented with a single seed laser and single sideband modulators in a time-multiplexed manner, reducing the number of optical channels connected to the sensor head. In a compact sensor head containing the vacuum package, sub-Doppler cooling in the GMOT produces 15 μK temperatures, and the GMOT can operate at a 20 Hz data rate. We validated the atomic coherence with Ramsey interferometry using microwave spectroscopy, then demonstrated a light-pulse atom interferometer in a gravimeter configuration for a 10 Hz measurement data rate and T = 0–4.5 ms interrogation time, resulting in Δ g / g = 2.0 × 10 −6 . This work represents a significant step towards deployable cold-atom inertial sensors under large amplitude motional dynamics.

arXiv:2107.04792•Nature Communications•Sep 1, 2022•114 citations

A cold atom interferometry sensor platform based on diffractive optics and integrated photonics

Peter D. D. Schwindt, Jongmin Lee, Hayden McGuinness +15 more

We report the current progress in the development of a compact, deployable cold-atom interferometry sensor platform towards atomic sensors for position, navigation, and time (PNT) applications. A simplified atomic sensor head with diffractive optics, an alignment-free optical package, and photonic-integrated-circuit (PIC) compatible laser architecture [1] are essential for its compactness and deployability. This cold-atom sensor platform can be generally applied to gravimeters, accelerometers, gyroscopes, and clocks, and the sensor platform includes significant engineering efforts in the development of grating-mirror magneto-optical traps (G-MOTs), custom titanium vacuum package with passive pumping, and silicon photonics multi-channel on-chip single sideband modulators.

Optical and Quantum Sensing and Precision Metrology•Mar 4, 2021•0 citations

A cold atom interferometry sensor platform based on diffractive optics and integrated photonics.

Peter D. D. Schwindt

•Feb 1, 2021•0 citations
Abstract The extreme miniaturization of a cold-atom interferometer accelerometer requires the development of novel technologies and architectures for the interferometer subsystems. Here, we describe several component technologies and a laser system architecture to enable a path to such miniaturization. We developed a custom, compact titanium vacuum package containing a microfabricated grating chip for a tetrahedral grating magneto-optical trap (GMOT) using a single cooling beam. In addition, we designed a multi-channel photonic-integrated-circuit-compatible laser system implemented with a single seed laser and single sideband modulators in a time-multiplexed manner, reducing the number of optical channels connected to the sensor head. In a compact sensor head containing the vacuum package, sub-Doppler cooling in the GMOT produces 15 μK temperatures, and the GMOT can operate at a 20 Hz data rate. We validated the atomic coherence with Ramsey interferometry using microwave spectroscopy, then demonstrated a light-pulse atom interferometer in a gravimeter configuration for a 10 Hz measurement data rate and T = 0–4.5 ms interrogation time, resulting in Δ g / g = 2.0 × 10 −6 . This work represents a significant step towards deployable cold-atom inertial sensors under large amplitude motional dynamics.
We report the current progress in the development of a compact, deployable cold-atom interferometry sensor platform towards atomic sensors for position, navigation, and time (PNT) applications. A simplified atomic sensor head with diffractive optics, an alignment-free optical package, and photonic-integrated-circuit (PIC) compatible laser architecture [1] are essential for its compactness and deployability. This cold-atom sensor platform can be generally applied to gravimeters, accelerometers, gyroscopes, and clocks, and the sensor platform includes significant engineering efforts in the development of grating-mirror magneto-optical traps (G-MOTs), custom titanium vacuum package with passive pumping, and silicon photonics multi-channel on-chip single sideband modulators.