A compact cold-atom interferometer with a high data-rate grating magneto-optical trap and a photonic-integrated-circuit-compatible laser system
Jongmin Lee, Roger Ding, Justin Christensen, Randy R. Rosenthal, Aaron M. Ison, Daniel Gillund, David Bossert, Kyle Fuerschbach, William Kindel, Patrick Sean Finnegan, Joel R. Wendt, Michael R. Gehl, Ashok Kodigala, Hayden McGuinness, Charles Alan Walker, Shanalyn A. Kemme, Anthony L. Lentine, Grant W. Biedermann, Peter D. D. Schwindt
Abstract The extreme miniaturization of a cold-atom interferometer accelerometer requires the development of novel technologies and architectures for the interferometer subsystems. Here, we describe several component technologies and a laser system architecture to enable a path to such miniaturization. We developed a custom, compact titanium vacuum package containing a microfabricated grating chip for a tetrahedral grating magneto-optical trap (GMOT) using a single cooling beam. In addition, we designed a multi-channel photonic-integrated-circuit-compatible laser system implemented with a single seed laser and single sideband modulators in a time-multiplexed manner, reducing the number of optical channels connected to the sensor head. In a compact sensor head containing the vacuum package, sub-Doppler cooling in the GMOT produces 15 μK temperatures, and the GMOT can operate at a 20 Hz data rate. We validated the atomic coherence with Ramsey interferometry using microwave spectroscopy, then demonstrated a light-pulse atom interferometer in a gravimeter configuration for a 10 Hz measurement data rate and T = 0–4.5 ms interrogation time, resulting in Δ g / g = 2.0 × 10 −6 . This work represents a significant step towards deployable cold-atom inertial sensors under large amplitude motional dynamics.
Abstract The extreme miniaturization of a cold-atom interferometer accelerometer requires the development of novel technologies and architectures for the interferometer subsystems. Here, we describe several component technologies and a laser system architecture to enable a path to such miniaturization. We developed a custom, compact titanium vacuum package containing a microfabricated grating chip for a tetrahedral grating magneto-optical trap (GMOT) using a single cooling beam. In addition, we designed a multi-channel photonic-integrated-circuit-compatible laser system implemented with a single seed laser and single sideband modulators in a time-multiplexed manner, reducing the number of optical channels connected to the sensor head. In a compact sensor head containing the vacuum package, sub-Doppler cooling in the GMOT produces 15 μK temperatures, and the GMOT can operate at a 20 Hz data rate. We validated the atomic coherence with Ramsey interferometry using microwave spectroscopy, then demonstrated a light-pulse atom interferometer in a gravimeter configuration for a 10 Hz measurement data rate and T = 0–4.5 ms interrogation time, resulting in Δ g / g = 2.0 × 10 −6 . This work represents a significant step towards deployable cold-atom inertial sensors under large amplitude motional dynamics.
Light-pulse atom interferometry has emerged as a promising approach for developing quantum inertial and gravity sensors for real-world applications, but achieving robust operation in dynamic environments without sacrificing sensitivity remains challenging. To mitigate performance degradations resulting from vibration-induced noise and mismatches in the spatial overlap between free-falling atoms and light pulses, we demonstrate a first-of-a-kind high-data-rate, high-sensitivity grating magneto-optical trap (GMOT)-based light-pulse atom interferometer (LPAI). This system uses a compact, rugged GMOT architecture, based on an in-vacuum microfabricated grating chip and a single laser-cooling beam, to enable high-data-rate GMOT-based cold-atom generation with sub-Doppler cooling. Our GMOT-based LPAI operates at high data rates (up to 100 Hz), while simultaneously achieving both high acceleration sensitivity (550 ng/rt-Hz at 20 Hz, 1.49 ug/rt-Hz at 45 Hz, and 6.31 ug/rt-Hz at 70 Hz) and good bias stability (71 ng). This compact, rugged architecture paves the way for field-deployable quantum inertial and gravity sensors in high dynamics and for time-multiplexed, multi-axis inertial sensing.
We report the current progress in the development of a compact, deployable cold-atom interferometry sensor platform towards atomic sensors for position, navigation, and time (PNT) applications.A simplified atomic sensor head with diffractive optics, a fixed-alignment optical package, and photonic-integrated-circuit (PIC) compatible laser architecture [1] are essential for its compactness and deployability.This cold atom sensor platform can be generally applied to gravimeters, accelerometers, gyroscopes, and clocks, and the sensor platform includes significant engineering efforts in the development of grating-mirror magneto-optical traps (G-MOTs), ridgid structural design, a custom titanium vacuum package with passive pumping, and silicon photonics multi-channel on-chip single sideband modulators.
We demonstrate a compact light-pulse atom interferometer (LPAI) with a high data-rate grating magneto-optical trap (GMOT) and a photonic-integrated-circuit (PIC)-compatible laser system. These efforts are aligned with one of our primary goals, LPAI operation in high-dynamic environments through ruggedization and miniaturization of the sensor head and laser systems. The compact sensor head is based on a custom vacuum package and a grating chip with fixed optical components. The high data-rate LPAI operation with a GMOT enables the operation of LPAIs in high dynamics. PIC-compatible and PIC-based laser systems are realized and used to demonstrate LPAIs towards miniature cold-atom inertial sensors. Acknowledgement This work was supported by the Laboratory Directed Research and Development program at Sandia National Laboratories and is funded under the DARPA APhI program. Sandia National Laboratories is a multi-mission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525. This paper describes technical results and analysis. Any subjective views or opinions that might be expressed in the paper do not necessarily represent the view of the U.S. Department of Energy or the United States Government.
We report the current progress in the development of a compact, deployable cold-atom interferometry sensor platform towards atomic sensors for position, navigation, and time (PNT) applications. A simplified atomic sensor head with diffractive optics, an alignment-free optical package, and photonic-integrated-circuit (PIC) compatible laser architecture [1] are essential for its compactness and deployability. This cold-atom sensor platform can be generally applied to gravimeters, accelerometers, gyroscopes, and clocks, and the sensor platform includes significant engineering efforts in the development of grating-mirror magneto-optical traps (G-MOTs), custom titanium vacuum package with passive pumping, and silicon photonics multi-channel on-chip single sideband modulators.
Compared with the conventional three-dimensional magneto-optical trap (3D MOT), the grating magneto-optical trap (GMOT) enables the cooling and trapping of atoms with only a single beam of light, thereby significantly reducing the overall volume of the device. Here, a grating chip with high diffraction efficiency is designed, and its parameters are optimized through simulations, which effectively suppresses the power of the zero-order diffracted light. Subsequently, the grating chip is fabricated and characterized, and using this chip, we successfully trap 1.7×106 atoms. The temperatures of the atomic cloud in the axial and radial directions are 5.6 mK and 17.0 mK, respectively. The successful implementation of the atom cooling and trapping experiment based on the diffraction grating provides important reference for the miniaturization of cold atom-based quantum sensors.
We present a demonstration of a cold-atom optical-microwave double resonance (DR) Ramsey clock utilising an additively manufactured loop-gap-resonator cavity and grating magneto-optical trap (GMOT). The use of additive manufacturing allows for complex cavity structures, more difficult to produce with traditional machining techniques, while the GMOT architecture significantly simplifies the optical system required to trap and cool the atomic sample. In the current demonstration a single laser is used to trap < 3 × 106 87Rb atoms, cool them to below 10 µK, optically pump and read-out state populations of the atoms after microwave interrogation. A Ramsey-type interrogation scheme is employed with an empirically evaluated optimum free evolution time of 10 ms, limited by the loss of signal due to atoms falling out of the read-out beam. We demonstrate a short-term stability of < 2×10−11τ−1/2, in reasonable agreement with the predicted short-term stability based on the signal to noise ratio of the measured Ramsey fringes. Excellent field homogeneity of the cavity microwave field is demonstrated though Rabi oscillations, while almost complete optical pumping and good field orientation is evidenced by Zeeman spectroscopy of the ground-state hyperfine energy levels. This work is a novel approach towards more compact and portable cold-atom microwave clocks with significant potential for further miniaturization of the system.