Brillouin spectroscopy and microscopy is widely used for remote sensing and imaging; however, the sensitivity of detection is often limited due to the available laser power for such measurements. Quantum light offers an alternative solution to such spectroscopy and imaging by reducing the noise below the classical shot-noise limit. We demonstrate the first results of Brillouin spectroscopy and imaging using quantum-enhanced detection and outline potential applications and future strategies for improved detection sensitivity.
Brillouin spectroscopy and microscopy is widely used for remote sensing and imaging; however, the sensitivity of detection is often limited due to the available laser power for such measurements. Quantum light offers an alternative solution to such spectroscopy and imaging by reducing the noise below the classical shot-noise limit. We demonstrate the first results of Brillouin spectroscopy and imaging using quantum-enhanced detection and outline potential applications and future strategies for improved detection sensitivity.
Brillouin microscopy is an emerging label-free imaging technique used to assess local viscoelastic properties. Quantum-enhanced stimulated Brillouin scattering is demonstrated using low power continuous-wave lasers at 795 nm. A signal-to-noise ratio enhancement of 3.4 dB is reported by using two-mode intensity-difference squeezed light generated with the four-wave mixing process in atomic rubidium vapor. The low optical power and the excitation wavelengths in the water transparency window have the potential to provide a powerful bio-imaging technique for probing mechanical properties of biological samples prone to phototoxicity and thermal effects. The performance enhancement affordable through the use of quantum light may pave the way for significantly improved sensitivity that cannot be achieved classically. The proposed method for utilizing squeezed light for enhanced stimulated Brillouin scattering can be easily adapted for both spectroscopic and imaging applications in biology.
Without light, there would be no sight. Light acts as a probe in various measurement techniques ranging from imaging to spectroscopy, from small scale cantilever displace- ment measurement in atomic force microscopy to large scale mirror motion in interfer- ometry, light detection and ranging (LIDAR) and many other fields. As the light probe intensity rises, it not only allows reducing the background noise effect, but it also aids precision to the measurement by reducing the photon noise (shot-noise) contribution. However, increasing intensity beyond certain threshold level is not always advantageous for ultra sensitive measurements. For example in the detection of gravitational waves, the current power circulating in the large scale interferometers can not be increased further without introducing other noise sources like thermal effects on the mirrors, un- wanted scattered photons, and back action due to radiation pressure. In the imaging of delicate photo sensitive sample, high power can causes cell damage or it may lead to disturb the regular process under investigation, viz. favouring certain biochemical reaction, which do not correspond to natural in vitro behaviour. At low intensity, pho- ton noise is an important concern and quantum states of light with correlated photon fluctuation can ideally represent a fruitful way to build specific measurement strategies to surpass the limitation of standard approach based on classical light sources, offering an avenue of solutions for ultra sensitive measurements. This thesis work focuses on two application of quantum enhanced measurement strate- gies. The first part of the thesis work has been dedicated to the realization of the first wide-field microscope with Sub Shot Noise (SSN) sensitivity. This is based on the ex- ploitation of quantum correlations in the Squeezed Vacuum state. In the second part, the investigations have made on the role of the quantum correlated beams in an unusual interferometric scheme, in which two identical optical interferometers are subject to the same phase fluctuation. The scheme, in the classical regime, has been already imple- mented in a large scale experiment devoted to the search of possible quantum gravity (QG) effects at Fermilab.
Quantum enhanced optical measurement protocols aim at reducing the uncertainty in the estimation of some physical quantities of a system below the shot-noise limit, classically unavoidable. In particular when small number of photons is used the shot noise can be the main source of uncertainty, in these cases the use of quantum light is of great interest. Note that there are several situations where the number of photons in the probe can not be increased arbitrarily, as when fragile biological samples are under investigation. Two different imaging protocols are discussed in the following.
Stimulated Raman spectroscopy has become a powerful tool to study the spatiodynamics of molecular bonds with high sensitivity, resolution, and speed. However, the sensitivity and speed of state-of-the-art stimulated Raman scattering spectroscopy are currently limited by the shot-noise of the light beam probing the Raman process. Here, we demonstrate in a proof-of-principle experiment an enhancement of the sensitivity of continuous-wave stimulated Raman spectroscopy by reducing the quantum noise of the probing light below the shot-noise limit by means of amplitude squeezed states of light. Probing polymer samples with Raman shifts around 2950 c m − 1 with squeezed states, we demonstrate a quantum enhancement of the stimulated Raman signal-to-noise ratio (SNR) of 3.60 dB relative to the shot-noise limited SNR. Our proof-of-concept demonstration of quantum-enhanced continuous-wave Raman spectroscopy paves the way for more elaborate demonstrations using state-of-the-art stimulated Raman scattering microscopes, and thus constitutes the very first step towards a new generation of Raman microscopes, where weak Raman transitions can be imaged without the use of markers or an increase in the total optical power.
Quantum-enhanced metrology techniques offer ultra-precise timekeeping, allowing for breakthroughs in navigation systems, global positioning, medical and Biological imaging. Quantum metrology, a core application of quantum technologies, leverages non-classical states of light (such as entanglement and squeezing) to enhance measurement precision, sensitivity, and resolution beyond the classical limits, particularly the shot-noise limit. Its application to bio imaging and microscopy offers significant advantages for studying delicate biological specimens, which are often susceptible to damage from the intense light typically required by conventional high-resolution methods. The abstract highlights the potential of quantum properties of light to revolutionize bio imaging by providing a non-invasive, highly sensitive, and high-resolution platform for observing biological processes at fundamental scales.
Microscopes are indispensable tools in modern biology and medicine.With the development of microscopy, the signal-tonoise ratio of microscopes is now limited by the shot noise.Recently, quantum-enhanced microscopic imaging provides a feasible approach for improving the signal-to-noise ratio since it can beat the shot-noise limit by using quantum light.In this review, we first briefly introduce quantum states applied in quantum-enhanced microscopic imaging, and then we provide an overview of the principle and progress of quantum-enhanced stimulated Raman scattering microscopy, entangled twophoton microscopy, and quantum-enhanced differential interference contrast microscopy.