Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review Applied

Quantum Sensing of Magnetic Fields Using Global Optimization Algorithms

Wei Xiao, Yudong Ding, Teng Wu, Xiang Peng, Hong Mei Guo

Published Aug 17, 2023• 4 citations
Publisher

Abstract

Experimentally achieving optimal performance of quantum sensors, such as optically pumped magnetometers, is usually challenging and time consuming due to the complexity of the physical system. For a given experiment scheme, there are usually many experiment parameters that need to be fine tuned for achieving a satisfying performance of the quantum sensor. By employing global optimization algorithms, we propose an automatic and efficient way to optimize the sensor performance. We take the most sensitive magnetic field sensor, i.e., the optically pumped magnetometer, as an example to demonstrate how these algorithms facilitate the automatic optimization of quantum sensors. Both the optimization of zero-field magnetometers in a magnetic shield and the finite-field magnetometers in open Earth's field are demonstrated. A noise floor of approximately $10\phantom{\rule{0.2em}{0ex}}\mathrm{fT}/{\mathrm{Hz}}^{1/2}$ is achieved within a short time. This method provides an efficient way for quantum sensor optimization and will be helpful for the quantum sensor design.

DOI
10.1103/physrevapplied.20.024042

Related papers

Characterization of a quantum sensing system with an optically pumped magnetometer for micro-target detection

Barbecho Barrado, Adrià

Quantum sensing has appeared as a promising technique to push the sensitivities of sensors to inherent classical physical limitations. In particular, quantum magnetometers opens the possibilities of new range of applications where extreme sensitivities are needed. A zero field Optically Pumped Magnetometer (OPM), coupled to a conical magnetic guide (MG) is known as a promising technique to improve the spatial resolution of the sensor. This coupling, though, can produce disturbances in the optimal sensing point. In this work a set of compensating coils is designed to reduce the impact of the magnetic guide in the initial sub-15 $\fT/\sqrt{Hz}$ sensitivity of the commercial QuSpin QZFM. First, the system and different strategies are studied theoretically and later implemented experimentally, improving the sensitivity in the OPM-MG by an order of magnitude, from 100 $fT/\sqrt{Hz}$ originally, to 10 $fT/\sqrt{Hz}$.

•Jul 10, 2023•0 citations

The hunt for mineral resources with quantum magnetometers

Ronny Stolz, M. Schiffler, Michael Becken +2 more

Abstract Quantum sensing provides advanced technologies which significantly improve sensitivity and accuracy for sensing changes of motion, gravity, electric and magnetic field. Therein, quantum sensors for the detection of magnetic fields, so-called quantum magnetometers, are one of the most promising technological realizations. We firstly will provide a brief overview on methods in geophysical exploration benefitting from quantum magnetometers with resolution at the physical and technical limit. We will introduce recent developments on SQUID and OPM based sensors as specific implementations of a quantum magnetometer systems and application examples.

tm - Technisches Messen•Dec 14, 2023•10 citations

Optimal control of a quantum sensor: A fast algorithm based on an analytic solution

Antonello Scardicchio, Santiago Hernández-Gómez, Giovanni Fasiolo +3 more

Quantum sensors can show unprecedented sensitivities, provided they are controlled in a very specific, optimal way. Here, we consider a spin sensor of time-varying fields in the presence of dephasing noise, and we show that the problem of finding the pulsed control field that optimizes the sensitivity (i.e., the smallest detectable signal) can be mapped to the determination of the ground state of a spin chain. We find an approximate but analytic solution of this problem, which provides a lower bound for the sensitivity and a pulsed control very close to optimal, which we further use as initial guess for realizing a fast simulated annealing algorithm. We experimentally demonstrate the sensitivity improvement for a spin-qubit magnetometer based on a nitrogen-vacancy center in diamond.

arXiv:2112.14998•SciPost Physics•Jul 4, 2024•13 citations

Quantum magnetometry for space

Cameron Deans, T. Valenzuela, Mark G. Bason

The ability to measure the magnetic fields around celestial bodies enables various insights into processes and phenomena deep within such bodies.The use of magnetometry in space missions dates back to the 1950s, and a number of different technologies have been used to measure these fields, ranging from fluxgates to Anisotropic Magneto Resistance (AMR) sensors.Optically-pumped magnetometers (OPMs) represent the state-of-the-art in magnetic field sensitivity. 1 Such sensors rely upon the interaction of laser light to spin polarise a warm vapour of neutral atoms.Detecting the precession of these spins, again with laser light, is a direct way to measure a magnetic field and is relatable to fundamental constants.Improvements in quantum technology within the last decade have led to the miniaturisation of these sensors.We have now reached the point where compact, lightweight, and low power devices offer greater sensitivity to magnetic fields than any other technology.In this work, we identify the following four key space application areas in which OPMs may offer significant advantages over existing technologies: Environments in which high sensitivity is needed at low magnetic fields (10s of nT), full vector read-out with high directional sensitivity and reduced SWaP compared to helium magnetometers, miniaturised and lightweight scalar magnetometers to complement vector fluxgate measurements, vector or scalar sensors that need high (40 dB) gradiometer performance.This work identifies OPM configurations for each area and makes a first estimate of size, weight and power requirements for each.By enabling improvements in magnetic field sensitivity, this represents an exciting prospect for precision magnetic field measurements while also saving mass and reducing complexity.

International Conference on Space Optics (ICSO)•Jul 12, 2023•6 citations

Magnetic Field Compensation for An Optically Pumped Magnetometer Without Iteration

Yaqiong Niu, Chaofeng Ye

The most efficient way to improve the sensitivity of an optically pumped magnetometer (OPM) is to maximize the spin-polarization lifetime of the atoms. The spin exchange relaxation-free (SERF) OPM that operates in zero field environment is one of the most sensitive magnetic sensors. This paper proposes a new three-axis magnetic field compensation method for the single-beam OPM, which zeroes the magnetic field around the sensor to make it work in SERF regime. The method simultaneously employs two modulation magnetic fields and two low-frequency sweeping magnetic fields along two directions perpendicular to the laser beam during the compensation process. The output signal of the photodiode is demodulated at different frequencies, resulting in two outputs that reflect the three components of the magnetic field. This method does not require iterate to tune the three-axis field, which increases the speed of the compensation process significantly. The magnetic field resolutions of the method for the x-axis, y-axis and z-axis are 0.6 pT, 0.6 pT and 5 pt, respectively. A compact OPM with noise density about 20 fT / Hz1/2@10 Hz is developed and tested, demonstrating the feasibility of the method.

Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ...•Oct 29, 2023•1 citation

Multi-objective Optimization for SERF Atomic Magnetometer using Zero-field Parameter Modulation

Shushan Gao, Bangcheng Han, Zhuo Shi +5 more

The spin-exchange relaxation-free (SERF) atomic magnetometers exhibit ultrahigh sensitivity for the magnetic field measurement, and their performance is further enhanced through zero-field parameter modulation. However, this modulation introduces additional parameter coupling that limits the performance of magnetometers in multi-axis measurement. In this paper, we develop a modified dual-axis output equation based on the nonlinear interaction between the optical pumping rate and modulation field amplitude, mediated by the spin-exchange relaxation and polarization. We employ a multi-objective optimization algorithm incorporating the implicit constraints among these parameters to enable efficient, simultaneous optimization of both the pump rate and modulation amplitude. Experimental results show that under optimal parameters obtained by the algorithm, the dual-axis signal responses improve by approximately 20% and 30% over conventional optimization methods, achieving 2.5 fT/Hz1/2magnetic measurement sensitivities for the y-axis and 4.0 fT/Hz1/2for the x-axis, respectively.

IEEE International Conference on Electronic Measurement & Instruments•Aug 22, 2025•0 citations
Experimentally achieving optimal performance of quantum sensors, such as optically pumped magnetometers, is usually challenging and time consuming due to the complexity of the physical system. For a given experiment scheme, there are usually many experiment parameters that need to be fine tuned for achieving a satisfying performance of the quantum sensor. By employing global optimization algorithms, we propose an automatic and efficient way to optimize the sensor performance. We take the most sensitive magnetic field sensor, i.e., the optically pumped magnetometer, as an example to demonstrate how these algorithms facilitate the automatic optimization of quantum sensors. Both the optimization of zero-field magnetometers in a magnetic shield and the finite-field magnetometers in open Earth's field are demonstrated. A noise floor of approximately 10fT/Hz1/210\phantom{\rule{0.2em}{0ex}}\mathrm{fT}/{\mathrm{Hz}}^{1/2}10fT/Hz1/2 is achieved within a short time. This method provides an efficient way for quantum sensor optimization and will be helpful for the quantum sensor design.
Quantum sensing has appeared as a promising technique to push the sensitivities of sensors to inherent classical physical limitations. In particular, quantum magnetometers opens the possibilities of new range of applications where extreme sensitivities are needed. A zero field Optically Pumped Magnetometer (OPM), coupled to a conical magnetic guide (MG) is known as a promising technique to improve the spatial resolution of the sensor. This coupling, though, can produce disturbances in the optimal sensing point. In this work a set of compensating coils is designed to reduce the impact of the magnetic guide in the initial sub-15 $\fT/\sqrt{Hz}$ sensitivity of the commercial QuSpin QZFM. First, the system and different strategies are studied theoretically and later implemented experimentally, improving the sensitivity in the OPM-MG by an order of magnitude, from 100 fT/HzfT/\sqrt{Hz}fT/Hz​ originally, to 10 fT/HzfT/\sqrt{Hz}fT/Hz​.
Abstract Quantum sensing provides advanced technologies which significantly improve sensitivity and accuracy for sensing changes of motion, gravity, electric and magnetic field. Therein, quantum sensors for the detection of magnetic fields, so-called quantum magnetometers, are one of the most promising technological realizations. We firstly will provide a brief overview on methods in geophysical exploration benefitting from quantum magnetometers with resolution at the physical and technical limit. We will introduce recent developments on SQUID and OPM based sensors as specific implementations of a quantum magnetometer systems and application examples.
Quantum sensors can show unprecedented sensitivities, provided they are controlled in a very specific, optimal way. Here, we consider a spin sensor of time-varying fields in the presence of dephasing noise, and we show that the problem of finding the pulsed control field that optimizes the sensitivity (i.e., the smallest detectable signal) can be mapped to the determination of the ground state of a spin chain. We find an approximate but analytic solution of this problem, which provides a lower bound for the sensitivity and a pulsed control very close to optimal, which we further use as initial guess for realizing a fast simulated annealing algorithm. We experimentally demonstrate the sensitivity improvement for a spin-qubit magnetometer based on a nitrogen-vacancy center in diamond.
The ability to measure the magnetic fields around celestial bodies enables various insights into processes and phenomena deep within such bodies.The use of magnetometry in space missions dates back to the 1950s, and a number of different technologies have been used to measure these fields, ranging from fluxgates to Anisotropic Magneto Resistance (AMR) sensors.Optically-pumped magnetometers (OPMs) represent the state-of-the-art in magnetic field sensitivity. 1 Such sensors rely upon the interaction of laser light to spin polarise a warm vapour of neutral atoms.Detecting the precession of these spins, again with laser light, is a direct way to measure a magnetic field and is relatable to fundamental constants.Improvements in quantum technology within the last decade have led to the miniaturisation of these sensors.We have now reached the point where compact, lightweight, and low power devices offer greater sensitivity to magnetic fields than any other technology.In this work, we identify the following four key space application areas in which OPMs may offer significant advantages over existing technologies: Environments in which high sensitivity is needed at low magnetic fields (10s of nT), full vector read-out with high directional sensitivity and reduced SWaP compared to helium magnetometers, miniaturised and lightweight scalar magnetometers to complement vector fluxgate measurements, vector or scalar sensors that need high (40 dB) gradiometer performance.This work identifies OPM configurations for each area and makes a first estimate of size, weight and power requirements for each.By enabling improvements in magnetic field sensitivity, this represents an exciting prospect for precision magnetic field measurements while also saving mass and reducing complexity.
The most efficient way to improve the sensitivity of an optically pumped magnetometer (OPM) is to maximize the spin-polarization lifetime of the atoms. The spin exchange relaxation-free (SERF) OPM that operates in zero field environment is one of the most sensitive magnetic sensors. This paper proposes a new three-axis magnetic field compensation method for the single-beam OPM, which zeroes the magnetic field around the sensor to make it work in SERF regime. The method simultaneously employs two modulation magnetic fields and two low-frequency sweeping magnetic fields along two directions perpendicular to the laser beam during the compensation process. The output signal of the photodiode is demodulated at different frequencies, resulting in two outputs that reflect the three components of the magnetic field. This method does not require iterate to tune the three-axis field, which increases the speed of the compensation process significantly. The magnetic field resolutions of the method for the x-axis, y-axis and z-axis are 0.6 pT, 0.6 pT and 5 pt, respectively. A compact OPM with noise density about 20 fT / Hz1/2@10 Hz is developed and tested, demonstrating the feasibility of the method.
The spin-exchange relaxation-free (SERF) atomic magnetometers exhibit ultrahigh sensitivity for the magnetic field measurement, and their performance is further enhanced through zero-field parameter modulation. However, this modulation introduces additional parameter coupling that limits the performance of magnetometers in multi-axis measurement. In this paper, we develop a modified dual-axis output equation based on the nonlinear interaction between the optical pumping rate and modulation field amplitude, mediated by the spin-exchange relaxation and polarization. We employ a multi-objective optimization algorithm incorporating the implicit constraints among these parameters to enable efficient, simultaneous optimization of both the pump rate and modulation amplitude. Experimental results show that under optimal parameters obtained by the algorithm, the dual-axis signal responses improve by approximately 20% and 30% over conventional optimization methods, achieving 2.5 fT/Hz1/2magnetic measurement sensitivities for the y-axis and 4.0 fT/Hz1/2for the x-axis, respectively.