Multi-objective Optimization for SERF Atomic Magnetometer using Zero-field Parameter Modulation

Shushan Gao, Bangcheng Han, Zhuo Shi, Xiaoyu Li, Ziao Liu, Zhongyu Wang, Jianwei Sheng, Jixi Lu

Published Aug 22, 2025• 0 citations
Publisher

Abstract

The spin-exchange relaxation-free (SERF) atomic magnetometers exhibit ultrahigh sensitivity for the magnetic field measurement, and their performance is further enhanced through zero-field parameter modulation. However, this modulation introduces additional parameter coupling that limits the performance of magnetometers in multi-axis measurement. In this paper, we develop a modified dual-axis output equation based on the nonlinear interaction between the optical pumping rate and modulation field amplitude, mediated by the spin-exchange relaxation and polarization. We employ a multi-objective optimization algorithm incorporating the implicit constraints among these parameters to enable efficient, simultaneous optimization of both the pump rate and modulation amplitude. Experimental results show that under optimal parameters obtained by the algorithm, the dual-axis signal responses improve by approximately 20% and 30% over conventional optimization methods, achieving 2.5 fT/Hz1/2magnetic measurement sensitivities for the y-axis and 4.0 fT/Hz1/2for the x-axis, respectively.

DOI
10.1109/icemi66537.2025.11306497

Related papers

Femtotesla all-optical dual-axis spin-exchange relaxation-free magnetometer

Xiaoyu Li, Bangcheng Han, Ziao Liu +4 more

The sensitivity of existing all-optical atomic magnetometers is significantly compromised due to the simultaneous influence of optical parameters on both optical pumping and optical modulation of atoms. The tight interlinkage of these processes poses challenges for their individual optimization, thereby restricting the achievable sensitivity. To address this issue, we developed a comprehensive optical modulation analytical model that fully considers the effects of dynamic optical pumping. Building upon this model, we introduced a multi-objective optimization method for optical parameters, leading to minimal non-sensitive axis crosstalk and optimal sensitivity. Experimental results demonstrated a femtotesla all-optical spin-exchange relaxation-free magnetometer with sensitivities of 2 fT/Hz1/2 along the y-axis and 4 fT/Hz1/2 along the x-axis, respectively. This advancement surpasses the sensitivity of existing optically modulated magnetometers and bears profound implications for the advancement and application of arrayed magnetometers.

Applied Physics Letters•Jun 17, 2024•16 citations

Magnetic Field Compensation for An Optically Pumped Magnetometer Without Iteration

Yaqiong Niu, Chaofeng Ye

The most efficient way to improve the sensitivity of an optically pumped magnetometer (OPM) is to maximize the spin-polarization lifetime of the atoms. The spin exchange relaxation-free (SERF) OPM that operates in zero field environment is one of the most sensitive magnetic sensors. This paper proposes a new three-axis magnetic field compensation method for the single-beam OPM, which zeroes the magnetic field around the sensor to make it work in SERF regime. The method simultaneously employs two modulation magnetic fields and two low-frequency sweeping magnetic fields along two directions perpendicular to the laser beam during the compensation process. The output signal of the photodiode is demodulated at different frequencies, resulting in two outputs that reflect the three components of the magnetic field. This method does not require iterate to tune the three-axis field, which increases the speed of the compensation process significantly. The magnetic field resolutions of the method for the x-axis, y-axis and z-axis are 0.6 pT, 0.6 pT and 5 pt, respectively. A compact OPM with noise density about 20 fT / Hz1/2@10 Hz is developed and tested, demonstrating the feasibility of the method.

Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ...•Oct 29, 2023•1 citation

Dual-Axis Closed Loop of a Single-Beam Atomic Magnetometer: Toward High Bandwidth and High Sensitivity

Junjian Tang, Yueyang Zhai, Binquan Zhou +2 more

Atomic magnetometers operated in spin-exchange relaxation-free (SERF) have the potential to replace superconducting quantum interference devices (SQUIDs) in the field of biomagnetism. Here, we demonstrate the dual-axis closed-loop control of a single-beam SERF magnetometer that allows sensing of two orthogonal magnetic fields simultaneously and independently with suppressed cross-talk effect, achieved by applying a rotating modulation field and using of the negative feedback. Operating in the dual-axis closed-loop mode with a miniature 4 × 4 × 4 mm 87Rb cell, we achieve magnetic field sensitivity of 20 fT/Hz1/2 and a bandwidth of 1.8 kHz. In addition to the experimental study of the sensitivity and bandwidth, we perform a theoretical analysis to the dual-axis response and develop an effective decoupling method. The implementation of closed-loop control enables the magnetometer to be robust against the disturbance of the ambient field, which could enlarge the dynamic range, enhance the systematic stability, and suppress the cross-talk effect. Such a simple, yet high-performance SERF magnetometer could be suitable as a promising candidate in the field of biomagnetism, allowing for a denser sensor array and opening up new possibilities for the noninvasive biomagnetic imaging.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2021•95 citations

Analysis and Suppression of the Cross-Axis Coupling Effect for Dual-Beam SERF Atomic Magnetometer

Fei Lu, Shuying Wang, Nuozhou Xu +3 more

Spin-exchange relaxation-free (SERF) atomic magnetometers operated under a near-zero magnetic field are used for vector magnetic field measurements with high sensitivity. Previously, the cross-axis coupling error evoked by a nonzero background magnetic field has been verified to be adverse in modulated single-beam magnetometers. Here, in a dual-beam unmodulated SERF magnetometer, we propose a somewhat different solution model for the cross-axis coupling effect where the field of interest couples with the interference field. Considering two cases where the transverse or longitudinal background field exists, the cross-axis coupling effect dependence on multiple factors is investigated here based on the dynamic response under a background magnetic field within ±5 nT. The theoretical and experimental investigation suggests that it has an adverse impact on the output response amplitude and phase and tilts the sensitive axis by several degrees, causing a measurement error on the dual-beam magnetometer. To suppress this effect, the background magnetic field is compensated through the PI closed-loop control. The coupling effect is effectively suppressed by 1.5 times at the 10–40 Hz low-frequency band and the sensitivity reaches 2.4 fT/Hz1/2.

Photonics•Oct 25, 2022•7 citations

Pulsed-Modulation Single-Beam Three-Axis Atomic Magnetometer

Shushan Gao, Xiaoyu Li, Jianwei Sheng +5 more

The three-axis spin-exchange relaxation-free (SERF) atomic magnetometer (AM) enables full-vector magnetic field measurements with high sensitivity, offering significant potential for improving the accuracy of magnetic source reconstruction. However, most existing three-axis schemes rely on multiple continuous high-frequency modulation fields, which reintroduce spin-exchange relaxation and induce interaxis crosstalk. Here, we propose a three-axis magnetic field measurement method based on pulsed magnetic field modulation. By applying a transverse rotating pulsed field and a longitudinal pulsed field, the three-axis components of the vector magnetic field can be extracted from the longitudinal transmitted optical signal. The pulsed magnetic field reduces the continuous interaction time of the modulation field via its duty cycle, thereby suppressing spin-exchange relaxation. The designed synchronized time-division three-axis pulsed fields avoid the coupling effect of multiaxis modulation on spin polarization in the overlap region, thus effectively minimizing interaxis crosstalk while enabling real-time three-axis measurement. Experimental results demonstrate that the proposed method reduces the modulation-induced spin-exchange relaxation rate by approximately 40 %, achieving transverse dual-axis sensitivity of 13 fT/Hz${}^{\text {1/2}}$for the$x$- and$y$-axes, and a longitudinal sensitivity of 70 fT/Hz${}^{\text {1/2}}$for the$z$-axis in a$4\times 4\times 4$mm${}^{\text {3 87}}$Rb vapor cell. The interaxis crosstalk is suppressed to less than 1 % over the 1–100-Hz bandwidth. The proposed scheme provides new insights for constructing compact and low-cost single-beam three-axis SERF AMs.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2026•0 citations

Biaxial zero-field atomic magnetometer with a multi-passed probe light

Yibo Qi, Shuying Wang, Nuozhou Xu +3 more

Multi-passed probe light can enhance the signal of atomic magnetometers by increasing the effective optical path length between the alkali metal atomic ensemble and the probe light, thereby strengthening the sensitivity. In recent years, multi-passed probe light has become an important method for improving the response signal and sensitivity of atomic magnetometers. To achieve biaxial magnetic field measurement while maintaining high sensitivity, a biaxial measurement spin-exchange relaxation-free (SERF) atomic magnetometer with a multi-passed probe light is proposed in this paper. The theoretical model and experimental advantages of using multi-passed probe light in longitudinal magnetic field modulation (Z-mode) SERF atomic magnetometers are analyzed. In this paper, a new model of output response of the Z-mode SERF atomic magnetometer based on multi-passed probe light is established, a compact reflective optical path is designed to increase the optical path between the probe light and the polarized alkali metal atomic ensemble, enhance the signal response, and achieve the suppression of low-frequency 1/f noise through longitudinal magnetic field modulation. Experimental results confirmed that the magnetic field sensitivity in the x- and y-axis of the multi-passed probe light configuration improved by 29% and 18%, respectively, compared to the single-pass configuration.

Optics Young Scientist Summit (OYSS)•Jan 22, 2025•0 citations
The spin-exchange relaxation-free (SERF) atomic magnetometers exhibit ultrahigh sensitivity for the magnetic field measurement, and their performance is further enhanced through zero-field parameter modulation. However, this modulation introduces additional parameter coupling that limits the performance of magnetometers in multi-axis measurement. In this paper, we develop a modified dual-axis output equation based on the nonlinear interaction between the optical pumping rate and modulation field amplitude, mediated by the spin-exchange relaxation and polarization. We employ a multi-objective optimization algorithm incorporating the implicit constraints among these parameters to enable efficient, simultaneous optimization of both the pump rate and modulation amplitude. Experimental results show that under optimal parameters obtained by the algorithm, the dual-axis signal responses improve by approximately 20% and 30% over conventional optimization methods, achieving 2.5 fT/Hz1/2magnetic measurement sensitivities for the y-axis and 4.0 fT/Hz1/2for the x-axis, respectively.
The sensitivity of existing all-optical atomic magnetometers is significantly compromised due to the simultaneous influence of optical parameters on both optical pumping and optical modulation of atoms. The tight interlinkage of these processes poses challenges for their individual optimization, thereby restricting the achievable sensitivity. To address this issue, we developed a comprehensive optical modulation analytical model that fully considers the effects of dynamic optical pumping. Building upon this model, we introduced a multi-objective optimization method for optical parameters, leading to minimal non-sensitive axis crosstalk and optimal sensitivity. Experimental results demonstrated a femtotesla all-optical spin-exchange relaxation-free magnetometer with sensitivities of 2 fT/Hz1/2 along the y-axis and 4 fT/Hz1/2 along the x-axis, respectively. This advancement surpasses the sensitivity of existing optically modulated magnetometers and bears profound implications for the advancement and application of arrayed magnetometers.
The most efficient way to improve the sensitivity of an optically pumped magnetometer (OPM) is to maximize the spin-polarization lifetime of the atoms. The spin exchange relaxation-free (SERF) OPM that operates in zero field environment is one of the most sensitive magnetic sensors. This paper proposes a new three-axis magnetic field compensation method for the single-beam OPM, which zeroes the magnetic field around the sensor to make it work in SERF regime. The method simultaneously employs two modulation magnetic fields and two low-frequency sweeping magnetic fields along two directions perpendicular to the laser beam during the compensation process. The output signal of the photodiode is demodulated at different frequencies, resulting in two outputs that reflect the three components of the magnetic field. This method does not require iterate to tune the three-axis field, which increases the speed of the compensation process significantly. The magnetic field resolutions of the method for the x-axis, y-axis and z-axis are 0.6 pT, 0.6 pT and 5 pt, respectively. A compact OPM with noise density about 20 fT / Hz1/2@10 Hz is developed and tested, demonstrating the feasibility of the method.
Atomic magnetometers operated in spin-exchange relaxation-free (SERF) have the potential to replace superconducting quantum interference devices (SQUIDs) in the field of biomagnetism. Here, we demonstrate the dual-axis closed-loop control of a single-beam SERF magnetometer that allows sensing of two orthogonal magnetic fields simultaneously and independently with suppressed cross-talk effect, achieved by applying a rotating modulation field and using of the negative feedback. Operating in the dual-axis closed-loop mode with a miniature 4 × 4 × 4 mm 87Rb cell, we achieve magnetic field sensitivity of 20 fT/Hz1/2 and a bandwidth of 1.8 kHz. In addition to the experimental study of the sensitivity and bandwidth, we perform a theoretical analysis to the dual-axis response and develop an effective decoupling method. The implementation of closed-loop control enables the magnetometer to be robust against the disturbance of the ambient field, which could enlarge the dynamic range, enhance the systematic stability, and suppress the cross-talk effect. Such a simple, yet high-performance SERF magnetometer could be suitable as a promising candidate in the field of biomagnetism, allowing for a denser sensor array and opening up new possibilities for the noninvasive biomagnetic imaging.
Spin-exchange relaxation-free (SERF) atomic magnetometers operated under a near-zero magnetic field are used for vector magnetic field measurements with high sensitivity. Previously, the cross-axis coupling error evoked by a nonzero background magnetic field has been verified to be adverse in modulated single-beam magnetometers. Here, in a dual-beam unmodulated SERF magnetometer, we propose a somewhat different solution model for the cross-axis coupling effect where the field of interest couples with the interference field. Considering two cases where the transverse or longitudinal background field exists, the cross-axis coupling effect dependence on multiple factors is investigated here based on the dynamic response under a background magnetic field within ±5 nT. The theoretical and experimental investigation suggests that it has an adverse impact on the output response amplitude and phase and tilts the sensitive axis by several degrees, causing a measurement error on the dual-beam magnetometer. To suppress this effect, the background magnetic field is compensated through the PI closed-loop control. The coupling effect is effectively suppressed by 1.5 times at the 10–40 Hz low-frequency band and the sensitivity reaches 2.4 fT/Hz1/2.
The three-axis spin-exchange relaxation-free (SERF) atomic magnetometer (AM) enables full-vector magnetic field measurements with high sensitivity, offering significant potential for improving the accuracy of magnetic source reconstruction. However, most existing three-axis schemes rely on multiple continuous high-frequency modulation fields, which reintroduce spin-exchange relaxation and induce interaxis crosstalk. Here, we propose a three-axis magnetic field measurement method based on pulsed magnetic field modulation. By applying a transverse rotating pulsed field and a longitudinal pulsed field, the three-axis components of the vector magnetic field can be extracted from the longitudinal transmitted optical signal. The pulsed magnetic field reduces the continuous interaction time of the modulation field via its duty cycle, thereby suppressing spin-exchange relaxation. The designed synchronized time-division three-axis pulsed fields avoid the coupling effect of multiaxis modulation on spin polarization in the overlap region, thus effectively minimizing interaxis crosstalk while enabling real-time three-axis measurement. Experimental results demonstrate that the proposed method reduces the modulation-induced spin-exchange relaxation rate by approximately 40 %, achieving transverse dual-axis sensitivity of 13 fT/Hz1/2{}^{\text {1/2}}1/2for thexxx- andyyy-axes, and a longitudinal sensitivity of 70 fT/Hz1/2{}^{\text {1/2}}1/2for thezzz-axis in a4×4×44\times 4\times 44×4×4mm3 87{}^{\text {3 87}}3 87Rb vapor cell. The interaxis crosstalk is suppressed to less than 1 % over the 1–100-Hz bandwidth. The proposed scheme provides new insights for constructing compact and low-cost single-beam three-axis SERF AMs.
Multi-passed probe light can enhance the signal of atomic magnetometers by increasing the effective optical path length between the alkali metal atomic ensemble and the probe light, thereby strengthening the sensitivity. In recent years, multi-passed probe light has become an important method for improving the response signal and sensitivity of atomic magnetometers. To achieve biaxial magnetic field measurement while maintaining high sensitivity, a biaxial measurement spin-exchange relaxation-free (SERF) atomic magnetometer with a multi-passed probe light is proposed in this paper. The theoretical model and experimental advantages of using multi-passed probe light in longitudinal magnetic field modulation (Z-mode) SERF atomic magnetometers are analyzed. In this paper, a new model of output response of the Z-mode SERF atomic magnetometer based on multi-passed probe light is established, a compact reflective optical path is designed to increase the optical path between the probe light and the polarized alkali metal atomic ensemble, enhance the signal response, and achieve the suppression of low-frequency 1/f noise through longitudinal magnetic field modulation. Experimental results confirmed that the magnetic field sensitivity in the x- and y-axis of the multi-passed probe light configuration improved by 29% and 18%, respectively, compared to the single-pass configuration.