Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Physics Letters

Characterization of 87Rb MEMS vapor cells for miniature atomic magnetometers

Minwei Jiang, Hao Zhai, Chunyu Jiang, Jian Wang, Chen Chen, Qi Zhang, Dongmin Wu, Baoshun Zhang, Zhongming Zeng, Jie Lin, Yiqun Wang, Peng Jin

Published Aug 7, 2023• 12 citations
Publisher

Abstract

Accurate characterization of atomic vapor cells is crucial for enhancing the sensitivity of miniature atomic magnetometers. In this study, a fast and efficient approach is developed to characterize relaxation properties of the inner surface of the 87Rb micro-electro-mechanical systems (MEMS) vapor cell. Based on the zero-field level crossing effect, the transverse relaxation rate was experimentally determined, and the depolarization coefficient of 0.097 for atom-wall collisions in the 87Rb MEMS vapor cell was obtained. The experiments demonstrated that the alkali-wall collision relaxation gradually dominates the depolarization of the 87Rb ensemble as the radius of the vapor cell decreases. This research provides a quantitative method to evaluate the effectiveness of the MEMS vapor cell anti-relaxation coatings and offers the design inspiration for MEMS atomic vapor cells from the perspective of relaxation characterization. It is beneficial for the development of weak magnetic field detections such as biomagnetism detection in ambient environments.

DOI
10.1063/5.0149388

Related papers

Level assessment of 87Rb in rubidium-filled MEMS vapor cells by X-ray imaging for atomic magnetometers

Minwei Jiang, Jian Wang, Hao Zhai +9 more

Abstract Quantitative assessments of the level and lifetime of alkali metal in the atomic vapor cells are essential for improving the stability of atomic magnetometers. In this paper, a fast and non-destructive approach is proposed to directly characterize the level of 87Rb in a hermetic MEMS vapor cell. The MEMS-compatible 87Rb evaporation technique is developed to dispense 87Rb in the vapor cells with high efficiency. The morphology of the metallic 87Rb in the MEMS vapor cell is visualized by the non-destructive X-ray technique, and the measured contact angle is 43° ± 2°. Combined with the image recognition, the quantitative characterization of the 87Rb is achieved, and the consumption rates of 87Rb in MEMS cells are experimentally investigated. The presented approach is beneficial for the fabrication and performance enhancement of vapor cells for atomic magnetometers.

Japanese Journal of Applied Physics•Apr 25, 2024•3 citations

Wafer-Level Micro Alkali Vapor Cells with Anti-Relaxation Coating Compatible with MEMS Packaging for Chip-Scale Atomic Magnetometers

Yu Ji, Jintang Shang, Qi Gan +1 more

Compared with superconducting quantum interference devices, chip-scale atomic magnetometers using the wafer-level micro alkali vapor cells can be used more conveniently in the applications of geophysical mapping, health care and remote monitoring. Drastic wall collisions and decreased polarization lifetime are the main barriers for the performance of the chip-scale atomic magnetometers. In this study, OTS organic films coated on the inner surface of the micro vapor cells were used to suppress wall collisions and improve polarization lifetime of the alkali atoms in the micro cells. First of all, the fabrication process of wafer-level micro OTS coated vapor cells is introduced, the process is based on anodic bonding technology. Then the prepared wafer-level micro OTS coated vapor cells have been characterized by the water-contact angle test and measured in the micro-machined spin-exchange relaxation free(SERF) atomic magnetometers. Results show that the OTS coating is effective after anodic bonding from the water contact angle test. Results also indicate that the spin exchange relaxation free atomic magnetometer using the micro OTS-coated vapor cell can operate successfully.

IEEE Electronic Components and Technology Conference (ECTC)•May 1, 2017•6 citations

Long-relaxation-time vapor cells for stability enhancement in SERF atomic spin co-magnetometers

Yi-an Xu, Yuan Hu, Haoran Xu +4 more

Spin-exchange relaxation-free (SERF) co-magnetometers exhibit broad application prospects in navigation-grade gyroscopes and fundamental physics experiments. However, their performance is constrained by finite spin relaxation times. To address this challenge, long-relaxation-time vapor cells have been realized through the introduction of dry-film anti-relaxation coatings. Such coatings form a stable hydrophobic layer on the inner walls of the vapor cell, which reduces the adsorption energy of alkali-metal atoms and suppresses wall-induced spin-destruction processes, thereby enhancing polarization retention and extending the coherence times of both electronic and nuclear spins. Nevertheless, a clear quantitative relationship between the coating properties and the resulting anti-relaxation performance has not yet been established. To resolve this issue, the present study introduces the background potential field in the Hamiltonian as an intermediate variable, linking the surface adsorption energy of the coating to atomic spin relaxation processes. From the perspective of microscopic energy structure, a theoretical mapping between coating characteristics and anti-relaxation performance is constructed, thereby filling a critical gap in the theoretical understanding of anti-relaxation coating mechanisms.

Sixth Symposium on Novel Optoelectronic Detection Technology and Applications•May 11, 2026•0 citations

Microfabricated alkali vapor cell with anti-relaxation wall coating

Rahel Straessle, Matthieu Pellaton, C. Affolderbach +4 more

We present a microfabricated alkali vapor cell equipped with an anti-relaxation wall coating. The anti-relaxation coating used is octadecyltrichlorosilane and the cell was sealed by thin-film indium-bonding at a low temperature of 140 °C. The cell body is made of silicon and Pyrex and features a double-chamber design. Depolarizing properties due to liquid Rb droplets are avoided by confining the Rb droplets to one chamber only. Optical and microwave spectroscopy performed on this wall-coated cell are used to evaluate the cell's relaxation properties and a potential gas contamination. Double-resonance signals obtained from the cell show an intrinsic linewidth that is significantly lower than the linewidth that would be expected in case the cell had no wall coating but only contained a buffer-gas contamination on the level measured by optical spectroscopy. Combined with further experimental evidence this proves the presence of a working anti-relaxation wall coating in the cell. Such cells are of interest for applications in miniature atomic clocks, magnetometers, and other quantum sensors.

Applied Physics Letters•Jul 28, 2014•74 citations

Characterization of high-temperature performance of cesium vapor cells with anti-relaxation coating

Wenhao Li, M. V. Balabas, Xiang Peng +4 more

Vapor cells with antirelaxation coating are widely used in modern atomic physics experiments due to the coating's ability to maintain the atoms' spin polarization during wall collisions. We characterize the performance of vapor cells with different coating materials by measuring longitudinal spin relaxation and vapor density at temperatures up to 95 °C. We infer that the spin-projection-noise-limited sensitivity for atomic magnetometers with such cells improves with temperature, which demonstrates the potential of antirelaxation coated cells in applications of future high-sensitivity magnetometers.

arXiv:1609.04867•Journal of Applied Physics•Feb 13, 2017•46 citations

Nuclear spin decoherence time in MEMS atomic vapor cells for applications in quantum technologies

Gilles Buchs, Sylvain Karlen, Thomas Overstolz +4 more

We report on the fabrication and characterization of MEMS atomic vapor cells suitable for applications in miniaturized quantum sensors such as atomic gyroscopes. Our MEMS cells are filled with natural abundance Rb alkali atoms and enriched noble Xe atoms and are operated in the regime of spin exchange optical pumping. The transverse relaxation time T2* of the nuclear spin in 129Xe atoms directly defines the angular random walk parameter of an atomic gyroscope. Using a field switch technique, we measure the dephasing time T2* of the 129Xe isotope as a function of temperature. Our results showing a decrease of T2* from about 1 to 0.4 seconds with an increasing temperature in the range from 80 to 150 °C are in good agreement with a simple theoretical model taking into account the most important decoherence mechanisms. We show that the observed decoherence behavior can be mostly explained trough collisions of the Xe atoms with the walls. Further characterization steps in order to gain more insight in the decoherence physics involved in our MEMS cells are discussed.

AIP conference proceedings•Jan 1, 2018•2 citations
Accurate characterization of atomic vapor cells is crucial for enhancing the sensitivity of miniature atomic magnetometers. In this study, a fast and efficient approach is developed to characterize relaxation properties of the inner surface of the 87Rb micro-electro-mechanical systems (MEMS) vapor cell. Based on the zero-field level crossing effect, the transverse relaxation rate was experimentally determined, and the depolarization coefficient of 0.097 for atom-wall collisions in the 87Rb MEMS vapor cell was obtained. The experiments demonstrated that the alkali-wall collision relaxation gradually dominates the depolarization of the 87Rb ensemble as the radius of the vapor cell decreases. This research provides a quantitative method to evaluate the effectiveness of the MEMS vapor cell anti-relaxation coatings and offers the design inspiration for MEMS atomic vapor cells from the perspective of relaxation characterization. It is beneficial for the development of weak magnetic field detections such as biomagnetism detection in ambient environments.
Abstract Quantitative assessments of the level and lifetime of alkali metal in the atomic vapor cells are essential for improving the stability of atomic magnetometers. In this paper, a fast and non-destructive approach is proposed to directly characterize the level of 87Rb in a hermetic MEMS vapor cell. The MEMS-compatible 87Rb evaporation technique is developed to dispense 87Rb in the vapor cells with high efficiency. The morphology of the metallic 87Rb in the MEMS vapor cell is visualized by the non-destructive X-ray technique, and the measured contact angle is 43° ± 2°. Combined with the image recognition, the quantitative characterization of the 87Rb is achieved, and the consumption rates of 87Rb in MEMS cells are experimentally investigated. The presented approach is beneficial for the fabrication and performance enhancement of vapor cells for atomic magnetometers.
Compared with superconducting quantum interference devices, chip-scale atomic magnetometers using the wafer-level micro alkali vapor cells can be used more conveniently in the applications of geophysical mapping, health care and remote monitoring. Drastic wall collisions and decreased polarization lifetime are the main barriers for the performance of the chip-scale atomic magnetometers. In this study, OTS organic films coated on the inner surface of the micro vapor cells were used to suppress wall collisions and improve polarization lifetime of the alkali atoms in the micro cells. First of all, the fabrication process of wafer-level micro OTS coated vapor cells is introduced, the process is based on anodic bonding technology. Then the prepared wafer-level micro OTS coated vapor cells have been characterized by the water-contact angle test and measured in the micro-machined spin-exchange relaxation free(SERF) atomic magnetometers. Results show that the OTS coating is effective after anodic bonding from the water contact angle test. Results also indicate that the spin exchange relaxation free atomic magnetometer using the micro OTS-coated vapor cell can operate successfully.
Spin-exchange relaxation-free (SERF) co-magnetometers exhibit broad application prospects in navigation-grade gyroscopes and fundamental physics experiments. However, their performance is constrained by finite spin relaxation times. To address this challenge, long-relaxation-time vapor cells have been realized through the introduction of dry-film anti-relaxation coatings. Such coatings form a stable hydrophobic layer on the inner walls of the vapor cell, which reduces the adsorption energy of alkali-metal atoms and suppresses wall-induced spin-destruction processes, thereby enhancing polarization retention and extending the coherence times of both electronic and nuclear spins. Nevertheless, a clear quantitative relationship between the coating properties and the resulting anti-relaxation performance has not yet been established. To resolve this issue, the present study introduces the background potential field in the Hamiltonian as an intermediate variable, linking the surface adsorption energy of the coating to atomic spin relaxation processes. From the perspective of microscopic energy structure, a theoretical mapping between coating characteristics and anti-relaxation performance is constructed, thereby filling a critical gap in the theoretical understanding of anti-relaxation coating mechanisms.
We present a microfabricated alkali vapor cell equipped with an anti-relaxation wall coating. The anti-relaxation coating used is octadecyltrichlorosilane and the cell was sealed by thin-film indium-bonding at a low temperature of 140 °C. The cell body is made of silicon and Pyrex and features a double-chamber design. Depolarizing properties due to liquid Rb droplets are avoided by confining the Rb droplets to one chamber only. Optical and microwave spectroscopy performed on this wall-coated cell are used to evaluate the cell's relaxation properties and a potential gas contamination. Double-resonance signals obtained from the cell show an intrinsic linewidth that is significantly lower than the linewidth that would be expected in case the cell had no wall coating but only contained a buffer-gas contamination on the level measured by optical spectroscopy. Combined with further experimental evidence this proves the presence of a working anti-relaxation wall coating in the cell. Such cells are of interest for applications in miniature atomic clocks, magnetometers, and other quantum sensors.
Vapor cells with antirelaxation coating are widely used in modern atomic physics experiments due to the coating's ability to maintain the atoms' spin polarization during wall collisions. We characterize the performance of vapor cells with different coating materials by measuring longitudinal spin relaxation and vapor density at temperatures up to 95 °C. We infer that the spin-projection-noise-limited sensitivity for atomic magnetometers with such cells improves with temperature, which demonstrates the potential of antirelaxation coated cells in applications of future high-sensitivity magnetometers.
We report on the fabrication and characterization of MEMS atomic vapor cells suitable for applications in miniaturized quantum sensors such as atomic gyroscopes. Our MEMS cells are filled with natural abundance Rb alkali atoms and enriched noble Xe atoms and are operated in the regime of spin exchange optical pumping. The transverse relaxation time T2* of the nuclear spin in 129Xe atoms directly defines the angular random walk parameter of an atomic gyroscope. Using a field switch technique, we measure the dephasing time T2* of the 129Xe isotope as a function of temperature. Our results showing a decrease of T2* from about 1 to 0.4 seconds with an increasing temperature in the range from 80 to 150 °C are in good agreement with a simple theoretical model taking into account the most important decoherence mechanisms. We show that the observed decoherence behavior can be mostly explained trough collisions of the Xe atoms with the walls. Further characterization steps in order to gain more insight in the decoherence physics involved in our MEMS cells are discussed.