Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Sensors

Enhanced Readout from Spatial Interference Fringes in a Point-Source Cold Atom Inertial Sensor

Jing Wang, Junze Tong, Wenbin Xie, Ziqian Wang, Yafei Feng, Xiaolong Wang

Published May 25, 2023• 3 citations
Publisher

Abstract

When the initial size of an atom cloud in a cold atom interferometer is negligible compared to its size after free expansion, the interferometer is approximated to a point-source interferometer and is sensitive to rotational movements by introducing an additional phase shear in the interference sequence. This sensitivity on rotation enables a vertical atom-fountain interferometer to measure angular velocity in addition to gravitational acceleration, which it is conventionally used to measure. The accuracy and precision of the angular velocity measurement depends on proper extraction of frequency and phase from spatial interference patterns detected via the imaging of the atom cloud, which is usually affected by various systematic biases and noise. To improve the measurement, a pre-fitting process based on principal component analysis is applied to the recorded raw images. The contrast of interference patterns are enhanced by 7-12 dB when the processing is present, which leads to an enhancement in the precision of angular velocity measurements from 6.3 μrad/s to 3.3 μrad/s. This technique is applicable in various instruments that involve precise extraction of frequency and phase from a spatial interference pattern.

DOI
10.3390/s23115071

Related papers

Robust inertial sensing with point-source atom interferometry for interferograms spanning a partial period

Yun-Jhih Chen, Azure Hansen, Moshe Shuker +3 more

Point source atom interferometry (PSI) uses the velocity distribution in a cold atom cloud to simultaneously measure one axis of acceleration and two axes of rotation from the spatial distribution of interferometer phase in an expanded cloud of atoms. Previously, the interferometer phase has been found from the phase, orientation, and period of the resulting spatial atomic interference fringe images. For practical applications in inertial sensing and precision measurement, it is important to be able to measure a wide range of system rotation rates, corresponding to interferograms with far less than one full interference fringe to very many fringes. Interferogram analysis techniques based on image processing used previously for PSI are challenging to implement for low rotation rates that generate less than one full interference fringe across the cloud. We introduce a new experimental method that is closely related to optical phase-shifting interferometry that is effective in extracting rotation values from signals consisting of fractional fringes as well as many fringes without prior knowledge of the rotation rate. The method finds the interferometer phase for each pixel in the image from four interferograms, each with a controlled Raman laser phase shift, to reconstruct the underlying atomic interferometer phase map without image processing.

arXiv:2005.11929•Optics Express•Oct 1, 2020•9 citations

Analytical tools for point source interferometry

Gregory W. Hoth, Bruno Pelle, John E. Kitching +1 more

Light pulse atom interferometry can be used to realize high-performance sensors of accelerations and rotations. In order to broaden the range of applications of these sensors, it is desirable to reduce their size and complexity. Point source interferometry (PSI) is a promising technique for accomplishing both of these goals. With PSI, rotations are measured by detecting the orientation and frequency of spatial fringe patterns in the atomic state. These spatial fringes are primarily due to a correlation between an atom's initial velocity and its final position, which is created by the expansion of a cold atom cloud. However, the fringe patterns are also influenced by the structure of the initial atomic distribution. We summarize several methods that can be used to investigate the relationship between the spatial fringe pattern and the initial atomic distribution. This relationship will need to be understood in detail to realize an accurate gyroscope based on PSI.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Feb 20, 2017•1 citation

Enhanced Atom Interferometer Readout through the Application of Phase Shear

Alex Sugarbaker, Susannah M. Dickerson, Jason M. Hogan +2 more

We present a method for determining the phase and contrast of a single shot of an atom interferometer. The application of a phase shear across the atom ensemble yields a spatially varying fringe pattern at each output port, which can be imaged directly. This method is broadly relevant to atom-interferometric precision measurement, as we demonstrate in a 10 m 87Rb atomic fountain by implementing an atom-interferometric gyrocompass with 10 mdeg precision.

arXiv:1305.3298•Physical Review Letters•Sep 10, 2013•132 citations

Simultaneous multi-axis inertial sensing with point source interferometry

Yujie Cheng, Azure Hansen, M. Shuker +3 more

In point source atom interferometry (PSI), a cloud of laser-cooled atom expands within a pair of counterpropagatingRaman laser beams and, after a beamsplitter-mirror-beamsplitter Raman pulse sequence, asingle snapshot of the expanded cloud allows simultaneous measurements of one axis of acceleration and two axes of rotation. In PSI, the thermal expansion of the cold-atom cloud, which is undesirable in other atom interferometry methods, is used to establish a position-velocity correlation in the expanded atom cloud. This correlation is employed to map the velocity dependence of the interferometric phaseshift onto a two-dimensional spatial image plane. As a result, the thermal velocity spread of the cloud of laser-cooled atoms facilitates the parallel operation of many atom interferometers, which yields the simultaneous multi-axis sensitivity. PSI provides a new approach to applications of atom interferometers in navigation and space science. For example, the 2D rotation measurement with PSI can be used to find geographic north or to measure the precession of a rotation vector. We have developed a scheme using PSI that is amenable to portable applications and we have demonstrated the measurement of a rotation vector in a plane [1]. We will present our recent results on evaluating the performance and systematic errors in a compact setup and discuss our proposals to address the challenges toward implementing ahigh-precision and portable PSI system.

•Apr 8, 2019•0 citations

Improve the performance of interferometer with ultra-cold atoms*

Xiangyu Dong, Shengjie Jin, Hongmian Shui +2 more

Ultra-cold atoms provide ideal platforms for interferometry. The macroscopic matter-wave property of ultra-cold atoms leads to large coherent length and long coherent time, which enable high accuracy and sensitivity to measurement. Here, we review our efforts to improve the performance of the interferometer. We demonstrate a shortcut method for manipulating ultra-cold atoms in an optical lattice. Compared with traditional ones, this shortcut method can reduce the manipulation time by up to three orders of magnitude. We construct a matter-wave Ramsey interferometer for trapped motional quantum states and significantly increase its coherence time by one order of magnitude with an echo technique based on this method. Efforts have also been made to enhance the resolution by multimode scheme. Application of a noise-resilient multi-component interferometer shows that increasing the number of paths could sharpen the peaks in the time-domain interference fringes, which leads to a resolution nearly twice compared with that of a conventional double-path two-mode interferometer. With the shortcut method mentioned above, improvement of the momentum resolution could also be fulfilled, which leads to atomic momentum patterns less than 0.6 ℏkL . To identify and remove systematic noises, we introduce the methods based on the principal component analysis (PCA) that reduce the noise in detection close to the 1 / 2 of the photon-shot noise and separate and identify or even eliminate noises. Furthermore, we give a proposal to measure precisely the local gravity acceleration within a few centimeters based on our study of ultracold atoms in precision measurements.

arXiv:2101.08953•Chinese Physics B•Dec 4, 2020•7 citations

A BEC Based Precision Gravimeter and Magnetic Gradiometer: Design and Implementation

Kyle S. Hardman

A precision inertial sensor based on the interference of matter waves has been designed and implemented. The apparatus is capable of producing both cold thermal and ultracold Bose-Einstein condensate (BEC) atomic ensembles as the inertial test mass. BECs of up to 5x10^6 Rubidium 87 atoms with an effective temperature of 50nK are produced every 13 seconds using a combination of two and three dimensional magneto-optical traps (2D and 3D MOT) and evaporative cooling in a hybrid magnetic-quadrupole and crossed optical dipole trap. The atomic cloud is then propagated through a vertically oriented Mach-Zehnder interferometer utilizing Bragg diffraction beam splitters. An 2.6m drop tube allows for up to 750ms of free fall and interferometer times of up to 250ms. The drop has four regions of imaging corresponding to 0, 25, 220, 530, and 750ms of expansion. Standard absorption imaging is used for the upper two imaging regions and frequency modulation imaging (FMI) is used for the lower regions. FMI exhibits near atom-shot noise limited signal-to-noise of 948 on a 1x10^6 atom cloud. The inertial reference is provided by the Bragg beam retro-reflector which is suspended via a geometric anti-spring passive vibration isolation system providing 65 dB of isolation at 70 Hz. Prior to the first interferometer pulse the ensemble is placed into a spin superposition of the |F=1> ground state manifold using horizontal co-propagating Raman beams. The three internal spin states remain orthogonal throughout the interferometer sequence resulting in three simultaneous interferometer with separable magnetic gradient and gravitational acceleration signals. The effects of meanfield energy on the interferometric phase uncertainty is explored under current trap conditions. It is found that 30 ms of free expansion prior to the first beam splitter decreases the internal energy such that the expected meanfield phase noise is below 1mrad. No significant decrease in the interferometer contrast is observed for all available T, whereas a thermal test mass interferometer of equivalent longitudinal temperature produces no interference at interferometer times > 100ms. A direct comparison of test mass spatial coherence length in an optically transversely confined interferometer is investigated. The visibility and contrast of a BEC and three thermal sources with varying spatial coherence are compared as a function of interferometer time. At short times, the fringe visibility of a BEC source approaches 100%, nearly independent of p pulse efficiency, while thermal sources have fringe visibilities limited to the p pulse efficiency. More importantly for precision measurement systems, the BEC source maintains interference at interferometer times significantly beyond that of the thermal source. A BEC test mass is used for the simultaneous precision measurement of gravity and magnetic field gradients. An 8 hour data run of a 130ms interferometer shows good agreement between the interferometer output and a theoretical model of the solid earth tides. The residual of the theoretical model and the experimental data show a 1000 run precision of dg/g = 1.45x10^9 corresponding to a phase noise of 3.8mrad. The integrated phase noise of the apparatus shows a sensitivity to magnetic field gradients of 120pT/m. By varying the central spatial position of a 40ms interferometer the magnetic field gradient along a portion of the drop tube is measured.

•Jan 1, 2016•4 citations
When the initial size of an atom cloud in a cold atom interferometer is negligible compared to its size after free expansion, the interferometer is approximated to a point-source interferometer and is sensitive to rotational movements by introducing an additional phase shear in the interference sequence. This sensitivity on rotation enables a vertical atom-fountain interferometer to measure angular velocity in addition to gravitational acceleration, which it is conventionally used to measure. The accuracy and precision of the angular velocity measurement depends on proper extraction of frequency and phase from spatial interference patterns detected via the imaging of the atom cloud, which is usually affected by various systematic biases and noise. To improve the measurement, a pre-fitting process based on principal component analysis is applied to the recorded raw images. The contrast of interference patterns are enhanced by 7-12 dB when the processing is present, which leads to an enhancement in the precision of angular velocity measurements from 6.3 μrad/s to 3.3 μrad/s. This technique is applicable in various instruments that involve precise extraction of frequency and phase from a spatial interference pattern.
Point source atom interferometry (PSI) uses the velocity distribution in a cold atom cloud to simultaneously measure one axis of acceleration and two axes of rotation from the spatial distribution of interferometer phase in an expanded cloud of atoms. Previously, the interferometer phase has been found from the phase, orientation, and period of the resulting spatial atomic interference fringe images. For practical applications in inertial sensing and precision measurement, it is important to be able to measure a wide range of system rotation rates, corresponding to interferograms with far less than one full interference fringe to very many fringes. Interferogram analysis techniques based on image processing used previously for PSI are challenging to implement for low rotation rates that generate less than one full interference fringe across the cloud. We introduce a new experimental method that is closely related to optical phase-shifting interferometry that is effective in extracting rotation values from signals consisting of fractional fringes as well as many fringes without prior knowledge of the rotation rate. The method finds the interferometer phase for each pixel in the image from four interferograms, each with a controlled Raman laser phase shift, to reconstruct the underlying atomic interferometer phase map without image processing.
Light pulse atom interferometry can be used to realize high-performance sensors of accelerations and rotations. In order to broaden the range of applications of these sensors, it is desirable to reduce their size and complexity. Point source interferometry (PSI) is a promising technique for accomplishing both of these goals. With PSI, rotations are measured by detecting the orientation and frequency of spatial fringe patterns in the atomic state. These spatial fringes are primarily due to a correlation between an atom's initial velocity and its final position, which is created by the expansion of a cold atom cloud. However, the fringe patterns are also influenced by the structure of the initial atomic distribution. We summarize several methods that can be used to investigate the relationship between the spatial fringe pattern and the initial atomic distribution. This relationship will need to be understood in detail to realize an accurate gyroscope based on PSI.
In point source atom interferometry (PSI), a cloud of laser-cooled atom expands within a pair of counterpropagatingRaman laser beams and, after a beamsplitter-mirror-beamsplitter Raman pulse sequence, asingle snapshot of the expanded cloud allows simultaneous measurements of one axis of acceleration and two axes of rotation. In PSI, the thermal expansion of the cold-atom cloud, which is undesirable in other atom interferometry methods, is used to establish a position-velocity correlation in the expanded atom cloud. This correlation is employed to map the velocity dependence of the interferometric phaseshift onto a two-dimensional spatial image plane. As a result, the thermal velocity spread of the cloud of laser-cooled atoms facilitates the parallel operation of many atom interferometers, which yields the simultaneous multi-axis sensitivity. PSI provides a new approach to applications of atom interferometers in navigation and space science. For example, the 2D rotation measurement with PSI can be used to find geographic north or to measure the precession of a rotation vector. We have developed a scheme using PSI that is amenable to portable applications and we have demonstrated the measurement of a rotation vector in a plane [1]. We will present our recent results on evaluating the performance and systematic errors in a compact setup and discuss our proposals to address the challenges toward implementing ahigh-precision and portable PSI system.
Ultra-cold atoms provide ideal platforms for interferometry. The macroscopic matter-wave property of ultra-cold atoms leads to large coherent length and long coherent time, which enable high accuracy and sensitivity to measurement. Here, we review our efforts to improve the performance of the interferometer. We demonstrate a shortcut method for manipulating ultra-cold atoms in an optical lattice. Compared with traditional ones, this shortcut method can reduce the manipulation time by up to three orders of magnitude. We construct a matter-wave Ramsey interferometer for trapped motional quantum states and significantly increase its coherence time by one order of magnitude with an echo technique based on this method. Efforts have also been made to enhance the resolution by multimode scheme. Application of a noise-resilient multi-component interferometer shows that increasing the number of paths could sharpen the peaks in the time-domain interference fringes, which leads to a resolution nearly twice compared with that of a conventional double-path two-mode interferometer. With the shortcut method mentioned above, improvement of the momentum resolution could also be fulfilled, which leads to atomic momentum patterns less than 0.6 ℏkL . To identify and remove systematic noises, we introduce the methods based on the principal component analysis (PCA) that reduce the noise in detection close to the 1 / 2 of the photon-shot noise and separate and identify or even eliminate noises. Furthermore, we give a proposal to measure precisely the local gravity acceleration within a few centimeters based on our study of ultracold atoms in precision measurements.
A precision inertial sensor based on the interference of matter waves has been designed and implemented. The apparatus is capable of producing both cold thermal and ultracold Bose-Einstein condensate (BEC) atomic ensembles as the inertial test mass. BECs of up to 5x10^6 Rubidium 87 atoms with an effective temperature of 50nK are produced every 13 seconds using a combination of two and three dimensional magneto-optical traps (2D and 3D MOT) and evaporative cooling in a hybrid magnetic-quadrupole and crossed optical dipole trap. The atomic cloud is then propagated through a vertically oriented Mach-Zehnder interferometer utilizing Bragg diffraction beam splitters. An 2.6m drop tube allows for up to 750ms of free fall and interferometer times of up to 250ms. The drop has four regions of imaging corresponding to 0, 25, 220, 530, and 750ms of expansion. Standard absorption imaging is used for the upper two imaging regions and frequency modulation imaging (FMI) is used for the lower regions. FMI exhibits near atom-shot noise limited signal-to-noise of 948 on a 1x10^6 atom cloud. The inertial reference is provided by the Bragg beam retro-reflector which is suspended via a geometric anti-spring passive vibration isolation system providing 65 dB of isolation at 70 Hz. Prior to the first interferometer pulse the ensemble is placed into a spin superposition of the |F=1> ground state manifold using horizontal co-propagating Raman beams. The three internal spin states remain orthogonal throughout the interferometer sequence resulting in three simultaneous interferometer with separable magnetic gradient and gravitational acceleration signals. The effects of meanfield energy on the interferometric phase uncertainty is explored under current trap conditions. It is found that 30 ms of free expansion prior to the first beam splitter decreases the internal energy such that the expected meanfield phase noise is below 1mrad. No significant decrease in the interferometer contrast is observed for all available T, whereas a thermal test mass interferometer of equivalent longitudinal temperature produces no interference at interferometer times > 100ms. A direct comparison of test mass spatial coherence length in an optically transversely confined interferometer is investigated. The visibility and contrast of a BEC and three thermal sources with varying spatial coherence are compared as a function of interferometer time. At short times, the fringe visibility of a BEC source approaches 100%, nearly independent of p pulse efficiency, while thermal sources have fringe visibilities limited to the p pulse efficiency. More importantly for precision measurement systems, the BEC source maintains interference at interferometer times significantly beyond that of the thermal source. A BEC test mass is used for the simultaneous precision measurement of gravity and magnetic field gradients. An 8 hour data run of a 130ms interferometer shows good agreement between the interferometer output and a theoretical model of the solid earth tides. The residual of the theoretical model and the experimental data show a 1000 run precision of dg/g = 1.45x10^9 corresponding to a phase noise of 3.8mrad. The integrated phase noise of the apparatus shows a sensitivity to magnetic field gradients of 120pT/m. By varying the central spatial position of a 40ms interferometer the magnetic field gradient along a portion of the drop tube is measured.