Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review Applied

Near-Field Sensing of Microwave Magnetic Field Phase Difference Enabled by N - V -Center Spins

Mingxin Li, Ning Zhang, Lixia Xu, Jixing Zhang, Guodong Bian, Pengcheng Fan, Sixian Wang, Heng Yuan

Published May 26, 2023• 12 citations
Publisher

Abstract

Sensing microwave (MW) fields through a quantum protocol has attracted increasing interest, and the phase of MW fields is an essential parameter in communication and quantum technologies. This work proposes a quantum-effect-based method for measuring the phase difference of MW magnetic fields under near-field conditions based on the selective transitions of nitrogen-vacancy- ($\mathrm{N}$-V) center spins in diamond. First, the relationship between the evolutions of the $\mathrm{N}$-V-center spin states and the phase difference of the MW magnetic fields, which are resonant and able to drive the transitions of the $\mathrm{N}$-V-center spins between ground-state energy levels, is deduced. Then, using a double-microstrip-line MW antenna, the variations in the Rabi frequency and maximum contrast as a function of the phase difference are experimentally revealed. Finally, the measurement of the phase difference is validated, and the sensitivity of the proof-of-principle method is estimated to be ${0.0915}^{\ensuremath{\circ}}/\sqrt{\text{Hz}}$. This method paves the way for the comprehensive quantum sensing of MW fields and has potential applications in the communication and quantum information fields.

DOI
10.1103/physrevapplied.19.054088

Related papers

Wideband microwave magnetometry using a nitrogen-vacancy center in diamond

Rui Li, Chengjie Wang, Cheng Zhi +6 more

Microwave magnetometry is essential to a variety of modern electronic techniques, most notably integrated circuits. The nitrogen-vacancy center in diamond has shown the ability of nanoscale resolution for the microwave magnetic field measurement and imaging. However, the characterization of the wideband magnetic field remains a challenge. Here we experimentally demonstrated a wideband microwave magnetometry with an off-resonance protocol based on the Bloch-Siegert shift effect. The off-resonance microwave magnetic field shifts the energy level of the nitrogen-vacancy center. It results in a phase accumulation during the evolution of the superposition state of the quantum sensor. According to this effect, by optimizing the evolution time, we experimentally verified the bandwidth widening of an order of magnitude compared with the Rabi oscillation, i.e., on-resonance method with an acceptable decrease of the sensitivity. In addition, we extracted the microwave frequency with a two-qubit system, which consists of a nitrogen-vacancy center and a nearby $^{13}\mathrm{C}$ nucleus. This approach enables the building of a wideband and potentially nanoscale microwave magnetometry to allow various potential applications, such as electronic circuits development.

Physical Review A•Jun 24, 2019•6 citations

Solid-State Quantum Microwave Standard Using Nitrogen-Vacancy Centers in Diamond

Masahiro Yamamoto, Moriyoshi Haruyama, Moto Kinoshita +3 more

Solid-state quantum sensors based on nitrogen-vacancy (NV) centers in diamond offer room-temperature operation, chemical stability, and a wide range of operating environments, and their application to microwave (MW) measurements are anticipated. In this study, we propose a method for quantitative MW field measurements under continuous-wave driving, referred to as the "NV Candle," aimed at realizing a solid-state quantum MW standard. Building on the atomic candle concept developed in atomic vapor systems, this method employs phase modulation of MW and resonance with Rabi oscillations to extract the Rabi frequency in the frequency domain. Experiments using NV centers in diamond demonstrated that the MW magnetic field derived from the NV Candle signals exhibited linearity over a 20 dB dynamic range. This work presents a novel approach to realize a solid-state quantum MW standard with enhanced robustness and practical applicability.

Conference on Precision Electromagnetic Measurements•Sep 1, 2026•0 citations

Impact of microwave phase noise on diamond quantum sensing

Andris Bērziņš, Maziar Saleh Ziabari, Yaser Silani +8 more

Precision optical measurements of the electron-spin precession of nitrogen-vacancy (NV) centers in diamond form the basis of numerous applications. The most sensitivity-demanding applications, such as femtotesla magnetometry, require the ability to measure changes in GHz spin transition frequencies at the sub-millihertz level, corresponding to a fractional resolution of better than 10 − 12 . Here we study the impact of microwave (MW) phase noise on the response of an NV sensor. Fluctuations of the phase of the MW waveform cause undesired rotations of the NV spin state. These fluctuations are imprinted in the optical readout signal and, left unmitigated, are indistinguishable from magnetic-field noise. We show that the phase noise of several common commercial MW generators results in an effective pT s 1 / 2 -range noise floor that varies with the MW carrier frequency and the detection frequency of the pulse sequence. The data are described by a frequency-domain model incorporating the MW phase-noise spectrum and the filter-function response of the sensing protocol. For controlled injection of white and random-walk phase noise, the observed NV magnetic noise floor is described by simple analytic expressions that accurately capture the scaling with pulse sequence length and the number of π pulses. We outline several strategies to suppress the impact of MW phase noise and implement a version, based on gradiometry, that realizes a > 10 -fold suppression. Our study highlights an important challenge in the pursuit of sensitive diamond quantum sensors and is applicable to other qubit systems with a large transition frequency. Published by the American Physical Society 2024

arXiv:2407.06465•Physical Review Research•Nov 15, 2024•14 citations

System for the remote control and imaging of MW fields for spin manipulation in NV centers in diamond

Giacomo Mariani, Shuhei Nomoto, Satoshi Kashiwaya +1 more

Nitrogen-vacancy (NV) centers in diamond have been used as platforms for quantum information, magnetometry and imaging of microwave (MW) fields. The spatial distribution of the MW fields used to drive the electron spin of NV centers plays a key role for these applications. Here, we report a system for the control and characterization of MW magnetic fields used for the NV spin manipulation. The control of the MW field in the vicinity of a diamond surface is mediated by an exchangeable lumped resonator, coupled inductively to a MW planar ring antenna. The characterization of the MW fields in the near-field is performed by an FFT imaging of Rabi oscillations, by using an ensemble of NV centers. We have found that the Rabi frequency over a lumped resonator is enhanced 22 times compared to the Rabi frequency without the presence of the lumped resonator. Our system may find applications in quantum information and magnetometry where a precise and controlled spin manipulation is required, showing NV centers as good candidates for imaging MW fields and characterization of MW devices.

Scientific Reports•Mar 16, 2020•46 citations

Vector dc magnetic-field sensing with a reference microwave field using perfectly aligned nitrogen-vacancy centers in diamond

Takuya Isogawa, Yuichiro Matsuzaki, Junko Ishi‐Hayase

The measurement of vector magnetic fields with high sensitivity and spatial resolution is important for both fundamental science and engineering applications. In particular, magnetic-field sensing with nitrogen-vacancy (NV) centers in diamond is a promising approach that can outperform existing methods. Recent studies have demonstrated vector dc magnetic-field sensing with perfectly aligned NV centers, which showed a higher readout contrast than NV centers having four equally distributed orientations. However, to estimate the azimuthal angle of the target magnetic field with respect to the NV axis in these previous approaches, it is necessary to apply a strong reference dc magnetic field, which can perturb the system to be measured. This is a crucial problem, especially when attempting to measure vector magnetic fields from materials that are sensitive to applied dc magnetic fields. Here, we propose a method to measure vector dc magnetic fields using perfectly aligned NV centers without reference dc magnetic fields. This method can be performed even with a single NV center. More specifically, we use the direction of linearly polarized microwave fields to induce Rabi oscillation as a reference and we estimate the azimuthal angle of the target fields from the Rabi frequency. We further demonstrate the potential of our method to improve sensitivity by using entangled states to overcome the standard quantum limit. Our method of using a reference microwave field is an alternative technique for sensitive vector dc magnetic-field sensing.

arXiv:2112.00506•Physical Review A•Jun 29, 2023•9 citations

Using a single nitrogen-vacancy center in diamond to detect microwave magnetic field vectors at resonant frequency

Mengyuan Cai, Changfeng Weng, Yuqing Zhu +3 more

This study introduces a method for reconstructing vector microwave magnetic fields using a single nitrogen-vacancy (NV) center in locally strong effective fields with two different orientations in diamond, without the previously required external magnetic field. Due to the varying orientations of the effective fields, NV centers exhibit two distinct sets of switchable ground states. The resonant Rabi oscillations of an NV center in these two distinct states were utilized to reconstruct vector microwave magnetic fields. Remarkably, this technique achieves an angular resolution of 0.02 mrad/Hz. Overcoming the limitations inherent in previous practices of using NV ensembles, this breakthrough has the potential to substantially enhance both the spatial resolution and the sensitivity of microwave magnetic field imaging, a meaningful development for various scientific and technological applications.

Applied Physics Letters•Apr 8, 2024•4 citations
Sensing microwave (MW) fields through a quantum protocol has attracted increasing interest, and the phase of MW fields is an essential parameter in communication and quantum technologies. This work proposes a quantum-effect-based method for measuring the phase difference of MW magnetic fields under near-field conditions based on the selective transitions of nitrogen-vacancy- (N\mathrm{N}N-V) center spins in diamond. First, the relationship between the evolutions of the N\mathrm{N}N-V-center spin states and the phase difference of the MW magnetic fields, which are resonant and able to drive the transitions of the N\mathrm{N}N-V-center spins between ground-state energy levels, is deduced. Then, using a double-microstrip-line MW antenna, the variations in the Rabi frequency and maximum contrast as a function of the phase difference are experimentally revealed. Finally, the measurement of the phase difference is validated, and the sensitivity of the proof-of-principle method is estimated to be 0.0915\ensuremath∘/Hz{0.0915}^{\ensuremath{\circ}}/\sqrt{\text{Hz}}0.0915\ensuremath∘/Hz​. This method paves the way for the comprehensive quantum sensing of MW fields and has potential applications in the communication and quantum information fields.
Microwave magnetometry is essential to a variety of modern electronic techniques, most notably integrated circuits. The nitrogen-vacancy center in diamond has shown the ability of nanoscale resolution for the microwave magnetic field measurement and imaging. However, the characterization of the wideband magnetic field remains a challenge. Here we experimentally demonstrated a wideband microwave magnetometry with an off-resonance protocol based on the Bloch-Siegert shift effect. The off-resonance microwave magnetic field shifts the energy level of the nitrogen-vacancy center. It results in a phase accumulation during the evolution of the superposition state of the quantum sensor. According to this effect, by optimizing the evolution time, we experimentally verified the bandwidth widening of an order of magnitude compared with the Rabi oscillation, i.e., on-resonance method with an acceptable decrease of the sensitivity. In addition, we extracted the microwave frequency with a two-qubit system, which consists of a nitrogen-vacancy center and a nearby 13C^{13}\mathrm{C}13C nucleus. This approach enables the building of a wideband and potentially nanoscale microwave magnetometry to allow various potential applications, such as electronic circuits development.
Solid-state quantum sensors based on nitrogen-vacancy (NV) centers in diamond offer room-temperature operation, chemical stability, and a wide range of operating environments, and their application to microwave (MW) measurements are anticipated. In this study, we propose a method for quantitative MW field measurements under continuous-wave driving, referred to as the "NV Candle," aimed at realizing a solid-state quantum MW standard. Building on the atomic candle concept developed in atomic vapor systems, this method employs phase modulation of MW and resonance with Rabi oscillations to extract the Rabi frequency in the frequency domain. Experiments using NV centers in diamond demonstrated that the MW magnetic field derived from the NV Candle signals exhibited linearity over a 20 dB dynamic range. This work presents a novel approach to realize a solid-state quantum MW standard with enhanced robustness and practical applicability.
Precision optical measurements of the electron-spin precession of nitrogen-vacancy (NV) centers in diamond form the basis of numerous applications. The most sensitivity-demanding applications, such as femtotesla magnetometry, require the ability to measure changes in GHz spin transition frequencies at the sub-millihertz level, corresponding to a fractional resolution of better than 10 − 12 . Here we study the impact of microwave (MW) phase noise on the response of an NV sensor. Fluctuations of the phase of the MW waveform cause undesired rotations of the NV spin state. These fluctuations are imprinted in the optical readout signal and, left unmitigated, are indistinguishable from magnetic-field noise. We show that the phase noise of several common commercial MW generators results in an effective pT s 1 / 2 -range noise floor that varies with the MW carrier frequency and the detection frequency of the pulse sequence. The data are described by a frequency-domain model incorporating the MW phase-noise spectrum and the filter-function response of the sensing protocol. For controlled injection of white and random-walk phase noise, the observed NV magnetic noise floor is described by simple analytic expressions that accurately capture the scaling with pulse sequence length and the number of π pulses. We outline several strategies to suppress the impact of MW phase noise and implement a version, based on gradiometry, that realizes a > 10 -fold suppression. Our study highlights an important challenge in the pursuit of sensitive diamond quantum sensors and is applicable to other qubit systems with a large transition frequency. Published by the American Physical Society 2024
Nitrogen-vacancy (NV) centers in diamond have been used as platforms for quantum information, magnetometry and imaging of microwave (MW) fields. The spatial distribution of the MW fields used to drive the electron spin of NV centers plays a key role for these applications. Here, we report a system for the control and characterization of MW magnetic fields used for the NV spin manipulation. The control of the MW field in the vicinity of a diamond surface is mediated by an exchangeable lumped resonator, coupled inductively to a MW planar ring antenna. The characterization of the MW fields in the near-field is performed by an FFT imaging of Rabi oscillations, by using an ensemble of NV centers. We have found that the Rabi frequency over a lumped resonator is enhanced 22 times compared to the Rabi frequency without the presence of the lumped resonator. Our system may find applications in quantum information and magnetometry where a precise and controlled spin manipulation is required, showing NV centers as good candidates for imaging MW fields and characterization of MW devices.
The measurement of vector magnetic fields with high sensitivity and spatial resolution is important for both fundamental science and engineering applications. In particular, magnetic-field sensing with nitrogen-vacancy (NV) centers in diamond is a promising approach that can outperform existing methods. Recent studies have demonstrated vector dc magnetic-field sensing with perfectly aligned NV centers, which showed a higher readout contrast than NV centers having four equally distributed orientations. However, to estimate the azimuthal angle of the target magnetic field with respect to the NV axis in these previous approaches, it is necessary to apply a strong reference dc magnetic field, which can perturb the system to be measured. This is a crucial problem, especially when attempting to measure vector magnetic fields from materials that are sensitive to applied dc magnetic fields. Here, we propose a method to measure vector dc magnetic fields using perfectly aligned NV centers without reference dc magnetic fields. This method can be performed even with a single NV center. More specifically, we use the direction of linearly polarized microwave fields to induce Rabi oscillation as a reference and we estimate the azimuthal angle of the target fields from the Rabi frequency. We further demonstrate the potential of our method to improve sensitivity by using entangled states to overcome the standard quantum limit. Our method of using a reference microwave field is an alternative technique for sensitive vector dc magnetic-field sensing.
This study introduces a method for reconstructing vector microwave magnetic fields using a single nitrogen-vacancy (NV) center in locally strong effective fields with two different orientations in diamond, without the previously required external magnetic field. Due to the varying orientations of the effective fields, NV centers exhibit two distinct sets of switchable ground states. The resonant Rabi oscillations of an NV center in these two distinct states were utilized to reconstruct vector microwave magnetic fields. Remarkably, this technique achieves an angular resolution of 0.02 mrad/Hz. Overcoming the limitations inherent in previous practices of using NV ensembles, this breakthrough has the potential to substantially enhance both the spatial resolution and the sensitivity of microwave magnetic field imaging, a meaningful development for various scientific and technological applications.