Impact of microwave phase noise on diamond quantum sensing
Andris Bērziņš, Maziar Saleh Ziabari, Yaser Silani, Ilja Fescenko, Joshua T. Damron, John F. Barry, Andrey Jarmola, Pauli Kehayias, Bryan A. Richards, Jānis Šmits, Víctor M. Acosta
Precision optical measurements of the electron-spin precession of nitrogen-vacancy (NV) centers in diamond form the basis of numerous applications. The most sensitivity-demanding applications, such as femtotesla magnetometry, require the ability to measure changes in GHz spin transition frequencies at the sub-millihertz level, corresponding to a fractional resolution of better than 10 − 12 . Here we study the impact of microwave (MW) phase noise on the response of an NV sensor. Fluctuations of the phase of the MW waveform cause undesired rotations of the NV spin state. These fluctuations are imprinted in the optical readout signal and, left unmitigated, are indistinguishable from magnetic-field noise. We show that the phase noise of several common commercial MW generators results in an effective pT s 1 / 2 -range noise floor that varies with the MW carrier frequency and the detection frequency of the pulse sequence. The data are described by a frequency-domain model incorporating the MW phase-noise spectrum and the filter-function response of the sensing protocol. For controlled injection of white and random-walk phase noise, the observed NV magnetic noise floor is described by simple analytic expressions that accurately capture the scaling with pulse sequence length and the number of π pulses. We outline several strategies to suppress the impact of MW phase noise and implement a version, based on gradiometry, that realizes a > 10 -fold suppression. Our study highlights an important challenge in the pursuit of sensitive diamond quantum sensors and is applicable to other qubit systems with a large transition frequency. Published by the American Physical Society 2024
Precision optical measurements of the electron-spin precession of nitrogen-vacancy (NV) centers in diamond form the basis of numerous applications. The most sensitivity-demanding applications, such as femtotesla magnetometry, require the ability to measure changes in GHz spin transition frequencies at the sub-millihertz level, corresponding to a fractional resolution of better than 10 − 12 . Here we study the impact of microwave (MW) phase noise on the response of an NV sensor. Fluctuations of the phase of the MW waveform cause undesired rotations of the NV spin state. These fluctuations are imprinted in the optical readout signal and, left unmitigated, are indistinguishable from magnetic-field noise. We show that the phase noise of several common commercial MW generators results in an effective pT s 1 / 2 -range noise floor that varies with the MW carrier frequency and the detection frequency of the pulse sequence. The data are described by a frequency-domain model incorporating the MW phase-noise spectrum and the filter-function response of the sensing protocol. For controlled injection of white and random-walk phase noise, the observed NV magnetic noise floor is described by simple analytic expressions that accurately capture the scaling with pulse sequence length and the number of π pulses. We outline several strategies to suppress the impact of MW phase noise and implement a version, based on gradiometry, that realizes a > 10 -fold suppression. Our study highlights an important challenge in the pursuit of sensitive diamond quantum sensors and is applicable to other qubit systems with a large transition frequency. Published by the American Physical Society 2024
The nitrogen-vacancy (NV) center in diamond is a leading solid-state platform for room-temperature quantum magnetometry owing to its long spin coherence times, optical spin initialization and readout, and high sensitivity to magnetic, electric, and thermal perturbations. As NV-based optically detected magnetic resonance (ODMR) systems transition from controlled laboratory environments toward portable and field-deployable sensors, a detailed understanding of realistic noise sources and experimental imperfections becomes essential for optimizing performance and sensitivity. In this work, we present a comprehensive simulation framework, i.e., a digital twin, for continuous-wave wide-field ODMR in NV-center ensembles. The model is built upon a physically consistent seven-level description of the NV center and incorporates a broad range of experimentally relevant noise and imperfection mechanisms as modular, parameterized components. These include laser and microwave amplitude fluctuations, microwave phase noise, uncertainty in the NV gyromagnetic ratio, spin dephasing, temperature-induced shifts of the ground-state zero-field splitting, surface-induced magnetic field perturbations, and photon shot noise. Power broadening and contrast degradation arising from optical and microwave driving are captured self-consistently through linewidth calculations. Also, the spatial inhomogeneity is modeled via a Gaussian laser intensity profile across the sensing region...
All-optical (AO) microwave-free magnetometry using nitrogen-vacancy (NV) centers in diamond simplifies experimental design and broadens sample compatibility. While continuous-wave (cw) detection of AO photoluminescence (PL) changes is commonly employed, its performance is susceptible to systematic fluctuations such as optical intensity noise. To address these challenges, we introduce a pulsed AO protocol that employs two PL measurements within an optical pulse to suppress common-mode noise. At near-zero magnetic field, we experimentally demonstrate that the pulsed AO protocol resolves AO-PL contrast features arising from NV-NV cross-relaxation, achieving up to 10× improvement in the low-frequency noise floor compared to conventional cw AO techniques. We further investigate the dependence of AO-PL contrast on PL readout timing and the dark time duration τ between optical pulses, with the optimal τ varying based on NV concentrations. These findings provide insights into optimizing NV-diamond samples for effective AO operation across diverse applications.
Solid-state quantum sensors based on nitrogen-vacancy (NV) centers in diamond offer room-temperature operation, chemical stability, and a wide range of operating environments, and their application to microwave (MW) measurements are anticipated. In this study, we propose a method for quantitative MW field measurements under continuous-wave driving, referred to as the "NV Candle," aimed at realizing a solid-state quantum MW standard. Building on the atomic candle concept developed in atomic vapor systems, this method employs phase modulation of MW and resonance with Rabi oscillations to extract the Rabi frequency in the frequency domain. Experiments using NV centers in diamond demonstrated that the MW magnetic field derived from the NV Candle signals exhibited linearity over a 20 dB dynamic range. This work presents a novel approach to realize a solid-state quantum MW standard with enhanced robustness and practical applicability.
Diamond based quantum sensing is a fast-emerging field with both scientific and technological importance. The nitrogen-vacancy (NV) center, a crystal defect in diamond, is a unique model system for microwave sensing application due to its excellent photo-stability, long spin coherence time in ambient conditions. In this work, we systematically optimized the measurement parameters for microwave sensing. The system noise is analyzed, and 1/f noise is suppressed by introducing a differential algorithm. The gain of avalanche photodiode and the gating window of the pulsed fluorescence is optimized to further suppress the noise floor. The decoherence of spin is characterized by varying the duration of the laser and microwave. The minimal detectable power on a standard microstrip is characterized with sampling time down to 1 ms, showing flat frequency dependence. The results have important implications toward fast measurement of broadband microwave power, especially in the field of IC testing and radar signal processing under intense electromagnetic interference.
Abstract Quantum systems composed of solid-state electronic spins can be sensitive detectors of narrowband magnetic fields. A prominent example is the nitrogen-vacancy (NV) center in diamond, which has been employed for magnetic spectroscopy with high spatial and spectral resolution. However, NV-diamond spectroscopy protocols are typically based on dynamical decoupling sequences, which are limited to low-frequency signals (≲ 20 MHz) due to the technical requirements on microwave (MW) pulses used to manipulate NV electronic spins. In this work, we experimentally demonstrate a high-resolution magnetic spectroscopy protocol that integrates a quantum frequency mixing (QFM) effect in a dense NV ensemble with coherently averaged synchronized readout (CASR) to provide both a wide range of signal frequency detection and sub-Hz spectral resolution. We assess the sensitivity of this QFM-CASR protocol across a frequency range of 10 MHz to 4 GHz. By measuring the spectra of multi-frequency signals near 0.6, 2.4 and 4 GHz, we demonstrate sub-Hz spectral resolution with a nT-scale noise floor for the target signal, and precise phase measurement with error <1°. Compared to state-of-the-art NV-diamond techniques for narrowband magnetic spectroscopy, the QFM-CASR protocol greatly extends the detectable frequency range, enabling applications in high-frequency radio frequency (RF) and MW signal microscopy and analysis, as well as tesla-scale nuclear magnetic resonance (NMR) spectroscopy of small samples.
We demonstrate 4π-steradian vector magnetic field sensing using an ensemble of nitrogen-vacancy (NV) centers in a single-crystal diamond coupled to a microwave (MW) cavity. The MW cavity enhances the spin-photon coupling which enables efficient, high-contrast spin-state readout via MW interrogation and removes the need for bulky optical collection components. An applied AC bias magnetic field lifts the zero-field degeneracy of the four crystallographic NV orientations, allowing each orientation to be individually addressed and used for vector reconstruction of the magnetic field. The resulting magnetometer has a 40\% contrast (20x higher than typical for optical spin-ensemble readout) and achieves a single-axis sensitivity of 250 pT/Hz which is flat from DC to 1 kHz. Noise models of the composite spin-cavity system establish MW amplitude noise as the dominant noise source and predict a thermal noise limit of 2 pT/Hz.