Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics and Precision Engineering

Development of a 220 GHz Ti superconducting TES detector array for CMB polarization experiment

Qianghui LUO, Wei MIAO, Feiming Li, Jiaqiang Zhong, Zheng Wang, Jiang‐Qiao Ding, Kangmin Zhou, Wen Zhang, Yuan Ren, Shengcai SHI

Published Jan 1, 2023• 0 citations
Publisher

Abstract

高灵敏度超导相变边缘探测器(Transition Edge Sensor,TES)在宇宙微波背景(Cosmic Microwave Background,CMB)辐射B模偏振探测方面具有重要的应用前景。本文设计并制备了220 GHz频段8×8像元的天线耦合钛超导TES探测器,实验表征了刻蚀前钛超导TES探测器的低温热导和噪声特性。实验结果显示,钛超导TES探测器低温电声相互作用主导热导约为485.4 pW/K,同时钛超导TES探测器噪声等效功率优于5×10-17 W/Hz0.5。原理上,钛超导TES探测器热导在刻蚀后会进一步减小,理论计算出刻蚀后钛超导TES探测器的热导约为38 pW/K,同时,其热起伏等效噪声功率理论值约为9.2×10-18 W/Hz0.5,因此,钛超导TES探测器在刻蚀后的噪声等效功率性能会进一步提升。

DOI
10.37188/ope.20233104.0442

Related papers

Developments of Superconducting Microwave Kinetic Inductance Detectors (MKID) for Measurements of Cosmic Microwave Background (CMB) Polarization

S. Mima, Otani Chiko, Kensuke Koga +2 more

IEICE Technical Report; IEICE Tech. Rep.•Apr 12, 2013•0 citations

Recent Developments of Commercially Fabricated Horn Antenna-Coupled Transition-Edge Sensor Bolometer Detectors for Next-Generation Cosmic Microwave Background Polarimetry Experiments

Aritoki Suzuki, Elijah Kane, Adrian Tae-Jin Lee +7 more

Journal of Low Temperature Physics•May 6, 2022•2 citations

Microfabrication of Arrays of Superconducting Transition Edge Sensors for CMB Measurements

Chrystian M. Posada, J. Ding, A. N. Bender +9 more

Bulletin of the American Physical Society•Mar 15, 2016•0 citations

A 220 GHz superconducting titanium transition edge sensor array developed for cosmic microwave background experiments

Qianghui Luo, Jiaqiang Zhong, Wei Miao +10 more

Abstract In this paper, we report on the design, fabrication, and characterization of a 220 GHz superconducting transition edge sensor (TES) array developed for ground-based cosmic microwave background (CMB) experiments. Unlike conventional TES arrays adopting thermometers made of bilayer superconducting films, the TES array has thermometers made of simpler single-layer titanium (Ti) film deposited on a suspended silicon nitride (SiN x ) membrane. The thermal weak link is realized by releasing the TES’s thermal island including the Ti thermometer by dry etching with xenon difluoride (XeF2), giving a typical thermal conductance of 25 pW K−1. Its thermal-conductance mechanism is further studied by fitting the measured TES’s complex impedance with a three-block thermal model. The dark and optical noise equivalent power (NEP) of a superconducting TES are both measured. Despite existing lens reflection and dielectric loss in the superconducting microstrip line, its typical optical NEP reaches 100 aW Hz−0.5, which meets the sensitivity requirement for ground-based CMB experiments.

Superconductor Science and Technology•Sep 6, 2023•11 citations

Development of low-noise two-stage dc-SQUID for TES detector readout

Nan Li, Mengjie Song, Sixiao Hu +9 more

Abstract Direct-current superconducting quantum interference devices (dc-SQUIDs) are one of the most sensitive magnetic detectors. These sensors are extensively used in the readout of superconducting transition edge sensors (TESs), which are used for the detection of weak signals. A cosmic microwave background (CMB) polarization telescope operating in 22–48 GHz is currently under developing. The TESs calorimeter of the telescope will be readout by a time-division multiplexer SQUID readout system. We develop a two-stage dc-SQUID amplifier circuit, comprising an input-stage SQUID with 4 SQUID cells and a series SQUID array with 100 SQUID cells. This configuration has been shown to achieve extremely high signal gain while effectively controlling system noise. We assess the system noise at 300 mK in an adiabatic demagnetization refrigerator. The measured magnetic flux noise of the two-stage SQUID circuit system is approximately 0.3 μ Φ 0 / Hz at 10 kHz. The current noise equivalent to the input coil of input SQUID is about 2.4 pA / Hz . This result meets the low-noise readout requirements of the CMB TES and other applications with TES detectors.

arXiv:2601.19565•Superconductor Science and Technology•Apr 1, 2026•0 citations

First Integration of Two-Level Time-Division Multiplexed Differential Readout With a Prototype CMB-S4 Detector Array

Brianna Cantrall, Shawn Henderson, Zeeshan Ahmed +11 more

Future cosmic microwave background (CMB) surveys will require an order of magnitude more detectors than are currently deployed in the most densely packed fielded experiments. This calls for a multiplexed readout capable of handling the increased integration complexity, heat load on the lowest temperature stages, and cost for such experiments. One choice of readout technology is direct current (DC) superconducting quantum interference device (SQUID)-based time-division multiplexing (TDM). This technology, along with transition-edge sensor (TES) detector technology, has been successfully deployed by multiple CMB experiments over the past decade. However, current experiments implementing TDM have not yet demonstrated the combination of multiplexing (MUX) factor, sampling rate, and noise performance at the scale of a next-generation experiment, such as CMB Stage 4 (CMB-S4). In order to meet these requirements, an advanced TDM architecture has been developed that features increased amplification of TES signals and increased bandwidth compared to previous MUX chip designs, as well as implementation of fully symmetric, differential circuits and hierarchical row addressing. We report on the first integration and noise characterization of this advanced TDM architecture with a prototype CMB-S4 dichroic detector wafer sensitive to the 90 and 150 GHz bands. Limitations of the legacy warm electronics used in this work preclude direct tests of the hierarchical MUX and fully differential signal paths; we instead focus on noise characterization at the SQUID and detector levels. Based on our measurements, the full system performance is projected to exceed CMB-S4 design requirements.

IEEE Transactions on Applied Superconductivity•Jul 29, 2026•1 citation
高灵敏度超导相变边缘探测器(Transition Edge Sensor,TES)在宇宙微波背景(Cosmic Microwave Background,CMB)辐射B模偏振探测方面具有重要的应用前景。本文设计并制备了220 GHz频段8×8像元的天线耦合钛超导TES探测器,实验表征了刻蚀前钛超导TES探测器的低温热导和噪声特性。实验结果显示,钛超导TES探测器低温电声相互作用主导热导约为485.4 pW/K,同时钛超导TES探测器噪声等效功率优于5×10-17 W/Hz0.5。原理上,钛超导TES探测器热导在刻蚀后会进一步减小,理论计算出刻蚀后钛超导TES探测器的热导约为38 pW/K,同时,其热起伏等效噪声功率理论值约为9.2×10-18 W/Hz0.5,因此,钛超导TES探测器在刻蚀后的噪声等效功率性能会进一步提升。
Abstract In this paper, we report on the design, fabrication, and characterization of a 220 GHz superconducting transition edge sensor (TES) array developed for ground-based cosmic microwave background (CMB) experiments. Unlike conventional TES arrays adopting thermometers made of bilayer superconducting films, the TES array has thermometers made of simpler single-layer titanium (Ti) film deposited on a suspended silicon nitride (SiN x ) membrane. The thermal weak link is realized by releasing the TES’s thermal island including the Ti thermometer by dry etching with xenon difluoride (XeF2), giving a typical thermal conductance of 25 pW K−1. Its thermal-conductance mechanism is further studied by fitting the measured TES’s complex impedance with a three-block thermal model. The dark and optical noise equivalent power (NEP) of a superconducting TES are both measured. Despite existing lens reflection and dielectric loss in the superconducting microstrip line, its typical optical NEP reaches 100 aW Hz−0.5, which meets the sensitivity requirement for ground-based CMB experiments.
Abstract Direct-current superconducting quantum interference devices (dc-SQUIDs) are one of the most sensitive magnetic detectors. These sensors are extensively used in the readout of superconducting transition edge sensors (TESs), which are used for the detection of weak signals. A cosmic microwave background (CMB) polarization telescope operating in 22–48 GHz is currently under developing. The TESs calorimeter of the telescope will be readout by a time-division multiplexer SQUID readout system. We develop a two-stage dc-SQUID amplifier circuit, comprising an input-stage SQUID with 4 SQUID cells and a series SQUID array with 100 SQUID cells. This configuration has been shown to achieve extremely high signal gain while effectively controlling system noise. We assess the system noise at 300 mK in an adiabatic demagnetization refrigerator. The measured magnetic flux noise of the two-stage SQUID circuit system is approximately 0.3 μ Φ 0 / Hz at 10 kHz. The current noise equivalent to the input coil of input SQUID is about 2.4 pA / Hz . This result meets the low-noise readout requirements of the CMB TES and other applications with TES detectors.
Future cosmic microwave background (CMB) surveys will require an order of magnitude more detectors than are currently deployed in the most densely packed fielded experiments. This calls for a multiplexed readout capable of handling the increased integration complexity, heat load on the lowest temperature stages, and cost for such experiments. One choice of readout technology is direct current (DC) superconducting quantum interference device (SQUID)-based time-division multiplexing (TDM). This technology, along with transition-edge sensor (TES) detector technology, has been successfully deployed by multiple CMB experiments over the past decade. However, current experiments implementing TDM have not yet demonstrated the combination of multiplexing (MUX) factor, sampling rate, and noise performance at the scale of a next-generation experiment, such as CMB Stage 4 (CMB-S4). In order to meet these requirements, an advanced TDM architecture has been developed that features increased amplification of TES signals and increased bandwidth compared to previous MUX chip designs, as well as implementation of fully symmetric, differential circuits and hierarchical row addressing. We report on the first integration and noise characterization of this advanced TDM architecture with a prototype CMB-S4 dichroic detector wafer sensitive to the 90 and 150 GHz bands. Limitations of the legacy warm electronics used in this work preclude direct tests of the hierarchical MUX and fully differential signal paths; we instead focus on noise characterization at the SQUID and detector levels. Based on our measurements, the full system performance is projected to exceed CMB-S4 design requirements.